Practical Calculation Method for the Short-Circuit Current of Power Grids with High Temperature Superconducting Fault Current Limiters

被引:3
|
作者
Hong, Hai-feng [1 ]
Yu, Meng-ze [1 ]
Zhang, Xiao-hui [1 ]
Huan, Jia-jia [1 ]
Sui, Yu [1 ]
Pan, Xian-xian [1 ]
机构
[1] Guangdong Power Grid Co Ltd, Grid Planning & Res Ctr, Guangzhou, Guangdong, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Electromechanical transient; High-temperature superconducting fault current limiter; Nonlinear impedance-current characteristic; Short-circuit current calculation; STABILITY; TRANSMISSION;
D O I
10.1007/s42835-019-00295-7
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the expansion of the power grid scale and the enhancement of network structure interconnection, the short-circuit current of power grids is increasingly close to the upper capacity limit of circuit breakers. The fault current limiter is effective in suppressing the short-circuit current of power grids, and with the mature development of superconducting technology, high-temperature superconducting fault current limiters (HTS-FCLs) have been widely used in power grids. Due to the nonlinear impedance-current characteristic of HTS-FCLs, the traditional short-circuit current calculation method is inapplicable to power grids with HTS-FCLs. First, based on the establishment of the electromechanical transient model and the short-circuit calculation model, the short-circuit current calculation procedure for power grids with HTS-FCLs is proposed. Second, the calculation methods for three-phase and single-phase short-circuit currents at the substation bus in power grids with HTS-FCLs are analyzed. Finally, three-phase and single-phase short-circuit currents at the 500 kV Xijiang substation bus in the Guangdong power grid are calculated as the study case. Simulation results show that compared with the situation where there is no HTS-FCL installed, the short-circuit current on the 500 kV bus decreases from 65.34 to 58.31 kA in terms of the three-phase short-circuit fault, and decreases from 54.56 to 46.62 kA in terms of the single-phase short-circuit fault, thus verifying the effectiveness and practicability of HTS-FCLs in suppressing the short-circuit current, which is significant for the safe, stable and reliable operation of the power grid.
引用
收藏
页码:945 / 953
页数:9
相关论文
共 50 条
  • [21] Fault Dynamic Behaviors Analysis and Practical Peak Short-circuit Current Calculation of Wind and Solar Power Sources
    Jia K.
    Li Y.
    Kong J.
    Bi T.
    Hu W.
    Liu J.
    Dianwang Jishu/Power System Technology, 2024, 48 (02): : 830 - 838
  • [22] Electrical insulation for High Temperature Superconducting Fault Current Limiters
    Mazzanti, Giovanni
    Kandia, Effrosyni
    Morandi, Antonio
    Fabbri, Massimo
    Ribani, Pier Luigi
    PROCEEDINGS OF THE 2013 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2013), VOLS 1 AND 2, 2013, : 337 - 340
  • [23] Sizing methodology for superconducting fault current limiters in HVDC grids
    Larruskain, D. Marene
    Etxegarai, Agurtzane
    Iturregi, Araitz
    Abarrategi, Oihane
    Eguia, Pablo
    2023 IEEE BELGRADE POWERTECH, 2023,
  • [24] Analysis of Short-circuit Current Calculation Method in Wind Power Plant Design
    Liu, Mingyang
    Pan, Wenxia
    Yang, Gang
    Liu, Hanjiang
    Wu, Di
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [25] CALCULATION OF SHORT-CIRCUIT CURRENT FLOWS
    FUCHS, R
    ENERGIETECHNIK, 1986, 36 (08): : 293 - 298
  • [26] Practical application issues of superconducting fault current limiters for electric power systems
    Lee, B. W.
    Sim, J.
    Park, K. B.
    Oh, I. S.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 620 - 623
  • [27] Calculation of minimal short-circuit current in parallel arrangement of cables for a three phase short-circuit fault
    Ksiazkiewicz, Andrzej
    Batura, Ryszard
    PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (05): : 124 - 128
  • [28] A Short-Circuit Current Calculation Method Based on Discrete Model for VSC-HVDC Grids
    Xin, Yechun
    Wang, Tuo
    Yang, Yong
    Wang, Weiru
    Feng, Zhibo
    Dong, Qian
    2019 4TH IEEE WORKSHOP ON THE ELECTRONIC GRID (EGRID), 2019, : 110 - 115
  • [29] Optimal location and minimum number of superconducting fault current limiters for the protection of power grids
    Zhang, Xiuchang
    Ruiz, H. S.
    Geng, Jianzhao
    Coombs, T. A.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2017, 87 : 136 - 143
  • [30] A fault control system using solid state circuit breakers and high temperature superconducting fault current limiters
    Hodges, B
    Dvorak, J
    Braun, C
    CONFERENCE RECORD OF THE 1996 TWENTY-SECOND INTERNATIONAL POWER MODULATOR SYMPOSIUM, 1996, : 232 - 234