Clinical experiences with intraoperative electrocochleography in cochlear implant recipients and its potential to reduce insertion trauma and improve postoperative hearing preservation

被引:20
作者
Buechner, Andreas [1 ]
Bardt, Michael [1 ]
Haumann, Sabine [1 ]
Geissler, Gunnar [2 ]
Salcher, Rolf [1 ]
Lenarz, Thomas [1 ]
机构
[1] Hannover Med Sch, Dept Otolaryngol, Hannover, Germany
[2] Adv Bion GmbH, European Res Ctr, Hannover, Germany
关键词
ROUND WINDOW ELECTROCOCHLEOGRAPHY; OUTCOMES; ELECTRODES; FREQUENCY; SYSTEM;
D O I
10.1371/journal.pone.0266077
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Access to low-frequency acoustic information in cochlear implant patients leads to better speech understanding in noise. Electrocochleography (ECochG) can provide real-time feedback about the health of the cochlea during the insertion process with the potential to reduce insertion trauma. We describe our experiences of using this technique. Data from 47 adult subjects with measurable residual hearing and an Advanced Bionics (Valencia, CA) SlimJ (46) or MidScala (1) electrode array were analyzed. ECochGs were recorded intraoperatively via the implant. The surgeon adjusted the course of the electrode insertion based on drops in the ECochG. The final array position was assessed using postoperative imaging and pure tone thresholds were measured before and after surgery. Three different patterns of ECochG response amplitude were observed: Growth, Fluctuating and Total Loss. Subjects in the growth group showed the smallest postoperative hearing loss. However, the group with fluctuating amplitudes showed no meaningful correlation between the ECochG responses and the postoperative hearing loss, indicating that amplitude alone is insufficient for detecting damage. Considering the phase of the signal additionally to the amplitude and reclassifying the data by both the phase and amplitude of the response into three groups Type I-Type III produced statistically significant correlations between postoperative hearing loss and the grouping based on amplitude and phase respectively. We showed significantly better hearing preservation for Type I (no drop in amplitude) and Type II (drop with a concurrent phase shift), while Type III (drop without concurrent phase shift) had more surgery induced hearing loss. ECochG potentials measured through the implant could provide valuable feedback during the electrode insertion. Both the amplitude and phase of the ECochG response are important to consider. More data needs to be evaluated to better understand the impact of the different signal components to design an automated system to alert the surgeon ahead of damaging the cochlea.
引用
收藏
页数:16
相关论文
共 41 条
[31]   Intraoperative Monitoring Using Cochlear Microphonics in Cochlear Implant Patients With Residual Hearing [J].
Radeloff, Andreas ;
Shehata-Dieler, Wafaa ;
Scherzed, Agmal ;
Rak, Kristen ;
Harnisch, Wilma ;
Hagen, Rudolf ;
Mlynski, Robert .
OTOLOGY & NEUROTOLOGY, 2012, 33 (03) :348-354
[32]  
RUBEN R. J., 1960, ANN OTOL RHINOL AND LARYNGOL, V69, P459
[33]   The Compound Action Potential in Subjects Receiving a Cochlear Implant [J].
Scott, William C. ;
Giardina, Christopher K. ;
Pappa, Andrew K. ;
Fontenot, Tatyana E. ;
Anderson, Meredith L. ;
Dillon, Margaret T. ;
Brown, Kevin D. ;
Pillsbury, Harold C. ;
Adunka, Oliver F. ;
Buchman, Craig A. ;
Fitzpatrick, Douglas C. .
OTOLOGY & NEUROTOLOGY, 2016, 37 (10) :1654-1661
[34]   THE AUDITORY NEUROPHONIC - BASIC PROPERTIES [J].
SNYDER, RL ;
SCHREINER, CE .
HEARING RESEARCH, 1984, 15 (03) :261-280
[35]   THE SOURCE ALONG THE BASILAR-MEMBRANE OF THE COCHLEAR MICROPHONIC POTENTIAL RECORDED BY SURFACE ELECTRODES IN MAN [J].
SOHMER, H ;
KINARTI, R ;
GAFNI, M .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1980, 49 (5-6) :506-514
[36]   Frequency map for the human cochlear spiral ganglion: Implications for cochlear implants [J].
Stakhovskaya, Olga ;
Sridhar, Divya ;
Bonham, Ben H. ;
Leake, Patricia A. .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2007, 8 (02) :220-233
[37]   Consensus Panel on a Cochlear Coordinate System Applicable in Histologic, Physiologic, and Radiologic Studies of the Human Cochlea [J].
Verbist, Berit M. ;
Skinner, Margaret W. ;
Cohen, Lawrence T. ;
Leake, Patricia A. ;
James, Chris ;
Boex, Colette ;
Holden, Timothy A. ;
Finley, Charles C. ;
Roland, Peter S. ;
Roland, Thomas, Jr. ;
Haller, Matt ;
Patrick, Jim F. ;
Jolly, Claude N. ;
Faltys, Mike A. ;
Briaire, Jeroen J. ;
Frijns, Johan H. M. .
OTOLOGY & NEUROTOLOGY, 2010, 31 (05) :722-730
[38]   Electric-acoustic stimulation of the auditory system -: New technology for severe hearing loss [J].
von Ilberg, C ;
Kiefer, J ;
Tillein, J ;
Pfenningdorff, T ;
Hartmann, R ;
Stürzebecher, E ;
Klinke, R .
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1999, 61 (06) :334-340
[39]   Toward a Better Understanding of Electrocochleography: Analysis of Real-Time Recordings [J].
Weder, Stefan ;
Bester, Christofer ;
Collins, Aaron ;
Shaul, Chanan ;
Briggs, Robert J. ;
O'Leary, Stephen .
EAR AND HEARING, 2020, 41 (06) :1560-1567
[40]   The nature of acoustic response: The relation between sound frequency and frequency of impulses in the auditory nerve [J].
Wever, EG ;
Bray, CW .
JOURNAL OF EXPERIMENTAL PSYCHOLOGY, 1930, 13 :373-387