Knee mechanics: a review of past and present techniques to determine in vivo loads

被引:86
作者
Komistek, RD
Kane, TR
Mahfouz, M
Ochoa, JA
Dennis, DA
机构
[1] Univ Tennessee, Dept Biomed Engn, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Oak Ridge, TN USA
[3] Stanford Univ, Stanford, CA 94305 USA
[4] Rocky Mtn Musculoskeletal Res Lab, Denver, CO USA
[5] A Johnson & Johnson Co, DePuy, Warsaw, IA USA
关键词
mathematical model; fluoroscopy; dynamics; kinetics; mechanics;
D O I
10.1016/j.jbiomech.2004.02.041
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This review article evaluates various techniques that have been used to determine in vivo loads in the human knee. Two main techniques that have been used are telemetry, which is an experimental approach, and mathematical modeling, which is a theoretical approach. Telemetric analyses have previously been used to determine the in vivo loading of the human hip and more recently evaluated in the determination of in vivo knee loads. Mathematical modeling approaches can be categorized two ways; those that use optimization techniques to solve an indeterminate system and those that utilize a reduction method that minimizes the number of unknowns, keeping the system solvable as the number of equations of motion are equal to the number of unknown quantities. More recently, we have developed an approach that relies fully on the use of in vivo data from fluoroscopy, CT scanning, magnetic resonant imaging and a revised motion analysis technique that involves only two markers on each rigid body. A review of all techniques revealed a wide range of forces at the human knee, ranging from 1.9 to 7.2 times body weight during level walking. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:215 / 228
页数:14
相关论文
共 60 条
[1]   Dynamic optimization of human walking [J].
Anderson, FC ;
Pandy, MG .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (05) :381-390
[2]  
BACKMAN S, 1957, ACTA RADIOLGICA S, V146
[3]   Relations between compressive axial forces in an instrumented massive femoral implant, ground reaction forces, and integrated electromyographs from vastus lateralis during various 'osteogenic' exercises [J].
Bassey, EJ ;
Littlewood, JJ ;
Taylor, SJG .
JOURNAL OF BIOMECHANICS, 1997, 30 (03) :213-223
[4]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[5]  
BERGMANN G, 1997, CLIN ORTHOPAEDICS, V335, P190
[6]  
BERNSTEIN NA, 1935, BIODYNAMICS LOCOMOTI
[7]   A MODEL OF LOWER-EXTREMITY MUSCULAR ANATOMY [J].
BRAND, RA ;
CROWNINSHIELD, RD ;
WITTSTOCK, CE ;
PEDERSEN, DR ;
CLARK, CR ;
VANKRIEKEN, FM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04) :304-310
[8]  
BRANDFONBRENER AG, 1994, MED PROBL PERFORM AR, V9, P1
[9]  
BRAUNE W, 1989, GANG MENSCHEN MP, P21
[10]   Concept, design and fabrication of smart orthopedic implants [J].
Burny, F ;
Donkerwolcke, M ;
Moulart, F ;
Bourgois, R ;
Puers, R ;
Van Schuylenbergh, K ;
Barbosa, M ;
Paiva, O ;
Rodes, F ;
Bégueret, JB ;
Lawes, P .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (07) :469-479