Local phenomena analysis of steam condensation in the presence of air

被引:47
作者
Bian, Haozhi [1 ]
Sun, Zhongning [1 ]
Ding, Ming [1 ]
Zhang, Nan [1 ]
机构
[1] Harbin Engn Univ, Fundamental Sci Nucl Safety & Simulat Technol Lab, Harbin 150001, Heilongjiang, Peoples R China
关键词
CFD; Condensation; Non-condensable gas; Air layer; Field profile; Experimental validation; TUBE EXTERNAL SURFACE; NONCONDENSABLE GASES; VERTICAL TUBE; CONTAINMENT; MIXTURES; RATES; CODE; PREDICTION; VALIDATION;
D O I
10.1016/j.pnucene.2017.08.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In severe accident scenarios (e.g. LOCA), the steam condensation inside the containment area is of vital importance. This is because the containment pressure peak and long-term residual heat removal are closely related to the steam condensation efficiency. Note that the gas inside the containment area is a mixture of steam and air/hydrogen. Steam condensation consisting of non-condensable gases has its own characteristics. Compared to pure steam condensation, it has a much lower heat transfer coefficient and the local phenomena are more complex. Considering that steam condensation is closely related to other phenomena in containment thermal-hydraulic analysis, further studies should be carried out. In the present work, the STAR-CCM+ software is used with a diffusion boundary layer condensation model. Various cases from the COPAIN and Su experiments are simulated and discussed. In the simulation of the COPAIN experiment, the effect of the mesh density (main-stream mesh size and the Y+ value) on the boundary heat flux is compared with the experimental data. Additionally, the local velocity, temperature, and air mass fraction are compared and discussed. In the simulations of the Su experiment, calculated results for the main-stream temperature, near-wall region temperature, and heat transfer coefficient are compared with experimental results and discussed. The COPAIN numerical results indicate that (i) the boundary heat flux decreases linearly with any increase in the air layer thickness of up to 5 mm, and the effect of the air layer weakens with further increases in thickness; (ii) the convective heat flux is only responsible for up to 9.1% of the total boundary heat flux; and (iii) the automatic wall treatment gives a reasonable prediction of steam condensation. The simulations of the Su experiment show that (i) there is no obvious temperature stratification in the main-stream along the vertical direction and (ii) the thickness of the air layer close to the condensation tube is around 6 mm. These results provide basic guidance for the future design of condensation heat transfer enhancement structures. (c) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:188 / 198
页数:11
相关论文
共 24 条
[1]  
[Anonymous], 2005, INT J HEAT TECHNOL
[2]   Prediction of light gas distribution in experimental containment facilities using the CFX4 code [J].
Babic, Miroslav ;
Kljenak, Ivo ;
Mavko, Borut .
NUCLEAR ENGINEERING AND DESIGN, 2008, 238 (03) :538-550
[3]  
Bird R B., 2002, Transportphenomena
[4]   Experimental data base for containment thermalhydraulic analysis [J].
Cheng, X ;
Bazin, P ;
Cornet, P ;
Hittner, D ;
Jackson, JD ;
Jimenez, JL ;
Naviglio, A ;
Oriolo, F ;
Petzold, H .
NUCLEAR ENGINEERING AND DESIGN, 2001, 204 (1-3) :267-284
[5]   Review on condensation on the containment structures [J].
de la Rosa, J. C. ;
Escriva, A. ;
Herranz, L. E. ;
Cicero, T. ;
Munoz-Cobo, J. L. .
PROGRESS IN NUCLEAR ENERGY, 2009, 51 (01) :32-66
[9]   Prediction of steam condensation in the presence of noncondensable gases using a CFD-based approach [J].
Dehbi, A. ;
Janasz, F. ;
Bell, B. .
NUCLEAR ENGINEERING AND DESIGN, 2013, 258 :199-210
[10]  
Dehbi A, 1991, INT HEATR TRANF AICH