Accuracy of Noncontrast Quiescent-Interval Single-Shot Lower Extremity MR Angiography Versus CT Angiography for Diagnosis of Peripheral Artery Disease Comparison With Digital Subtraction Angiography

被引:43
作者
Varga-Szemes, Akos [1 ]
Wichmann, Julian L. [1 ,2 ]
Schoepf, U. Joseph [1 ,3 ]
Suranyi, Pal [1 ,3 ]
De Cecco, Carlo N. [1 ]
Muscogiuri, Giuseppe [1 ,4 ]
Caruso, Damiano [1 ,5 ]
Yamada, Ricardo T. [1 ]
Litwin, Sheldon E. [3 ]
Tesche, Christian [1 ,6 ]
Duguay, Taylor M. [1 ]
Giri, Shivraman [7 ]
Vliegenthart, Rozemarijn [1 ,8 ]
Todoran, Thomas M. [3 ]
机构
[1] Med Univ South Carolina, Div Cardiovasc Imaging, Dept Radiol & Radiol Sci, Ashley River Tower,25 Courtenay Dr,MSC 226, Charleston, SC 29425 USA
[2] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[3] Med Univ South Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA
[4] Univ Rome Sapienza, Dept Med Surg Sci & Translat Med, Rome, Italy
[5] Univ Rome Sapienza, Dept Radiol Oncol & Pathol Sci, Rome, Italy
[6] Heart Ctr Munich Bogenhausen, Dept Cardiol & Intens Care Med, Munich, Germany
[7] Siemens Med Solut, Chicago, IL USA
[8] Univ Groningen, Univ Med Ctr Groningen, Ctr Med Imaging North East Netherlands, Dept Radiol, Groningen, Netherlands
关键词
cardiovascular magnetic resonance; noncontrast magnetic resonance angiography; quiescent interval single shot; MAGNETIC-RESONANCE ANGIOGRAPHY; IMAGE-QUALITY; STENOSIS; SPACE;
D O I
10.1016/j.jcmg.2016.09.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to evaluate the image quality and diagnostic accuracy of noncontrast quiescent-interval single-shot (QISS) magnetic resonance angiography (MRA) versus iodine-contrast computed tomography angiography (CTA) in patients with peripheral artery disease (PAD), with invasive digital subtraction angiography (DSA) as the reference standard. BACKGROUND QISS is a recently introduced noncontrast MRA technique. Although the diagnostic accuracy of QISS is reportedly similar to that of contrast-enhanced MRA, its performance compared with contrast-enhanced CTA, the most frequently used noninvasive modality for evaluation of PAD, is unknown. METHODS Thirty patients (66 +/- 7 years of age) with PAD underwent lower extremity CTA with third-generation dual-source dual-energy CT and 1.5-T MRA using a prototype noncontrast QISS sequence. DSA was performed within 50 days. The abdominal aorta and lower extremity run-off were imaged. Eighteen arterial segments were analyzed. Subjective image quality (3-point Likert scale) and stenosis (5-point grading) were evaluated by 2 observers and compared using the Mann-Whitney U and chi-square tests, respectively. Sensitivity and specificity of MRA and CTA for > 50% stenosis detection were compared using the McNemar-test. RESULTS Of 540 segments, 15 (2.8%) and 42 (7.8%) inconclusive segments were excluded from MRA and CTA analysis, respectively (p = 0.0006). The DSA results were available for 410 of the remaining segments. Overall subjective image quality was rated similarly with QISS-MRA (2.52 [95% confidence interval: 2.46 to 2.57]) and CTA (2.49 [95% confidence interval: 2.43 to 2.55]; p = 0.5062). The sensitivity and specificity of MRA for > 50% stenosis were 84.9% and 97.2%, respectively, similar to those of CTA (87.3% and 95.4%, respectively). Interobserver agreement for stenosis detection was excellent for MRA (kappa > 0.81) and CTA (kappa > 0.81). CONCLUSIONS Noncontrast QISS-MRA provides high diagnostic accuracy compared with DSA, while being less prone to image artifacts than CTA. QISS better visualizes heavily calcified segments with impaired flow. QISS-MRA obviates the need for contrast administration in PAD patients. (C) 2017 by the American College of Cardiology Foundation.
引用
收藏
页码:1116 / 1124
页数:9
相关论文
共 31 条
[1]  
American College of Radiology Committee on Drugs and Contrast Media, ACR MAN CONTR MED
[2]   Evaluating Peripheral Arterial Disease With Unenhanced Quiescent-Interval Single-Shot MR Angiography at 3 T [J].
Amin, Parag ;
Collins, Jeremy D. ;
Koktzoglou, Ioannis ;
Molvar, Christopher ;
Markl, Michael ;
Edelman, Robert R. ;
Carr, James C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (04) :886-893
[3]   Contrast Material-induced Nephrotoxicity and Intravenous Low-Osmolality Iodinated Contrast Material: Risk Stratification by Using Estimated Glomerular Filtration Rate [J].
Davenport, Matthew S. ;
Khalatbari, Shokoufeh ;
Cohan, Richard H. ;
Dillman, Jonathan R. ;
Myles, James D. ;
Ellis, James H. .
RADIOLOGY, 2013, 268 (03) :719-728
[4]   Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :375-385
[5]  
Dill KE, AM COLL RADIOLOGY AP
[6]   Quiescent-Inflow Single-Shot Magnetic Resonance Angiography Using a Highly Undersampled Radial k-Space Trajectory [J].
Edelman, R. R. ;
Giri, S. ;
Dunkle, E. ;
Galizia, M. ;
Amin, P. ;
Koktzoglou, I. .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) :1662-1668
[7]   Quiescent-Interval Single-Shot Unenhanced Magnetic Resonance Angiography of Peripheral Vascular Disease: Technical Considerations and Clinical Feasibility [J].
Edelman, Robert R. ;
Sheehan, John J. ;
Dunkle, Eugene ;
Schindler, Nancy ;
Carr, James ;
Koktzoglou, Ioannis .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) :951-958
[8]  
EdeLman RR, 2015, INT SOC MAGN RES MED
[9]   Optimal Vascular and Parenchymal Contrast Enhancement: The Current State of the Art [J].
Fleischmann, Dominik ;
Kamaya, Aya .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) :13-+
[10]   Low-dose multidetector-row CT angiography of the infra-renal aorta and lower extremity vessels: image quality and diagnostic accuracy in comparison with standard DSA [J].
Fraioli, F ;
Catalano, C ;
Napoli, A ;
Francone, M ;
Venditti, F ;
Danti, M ;
Pediconi, F ;
Passariello, R .
EUROPEAN RADIOLOGY, 2006, 16 (01) :137-146