Gait Segmentation Method Using a Plantar Pressure Measurement System with Custom-Made Capacitive Sensors

被引:47
作者
Aqueveque, Pablo [1 ]
Germany, Enrique [1 ]
Osorio, Rodrigo [1 ]
Pastene, Francisco [1 ]
机构
[1] Univ Concepcion, Fac Engn, Dept Elect Engn, 219 Edmundo Larenas St, Concepcion 4030000, Chile
关键词
capacitive sensors; gait analysis; gait segmentation; pressure sensors;
D O I
10.3390/s20030656
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gait analysis has been widely studied by researchers due to the impact in clinical fields. It provides relevant information on the condition of a patient's pathologies. In the last decades, different gait measurement methods have been developed in order to identify parameters that can contribute to gait cycles. Analyzing those parameters, it is possible to segment and identify different phases of gait cycles, making these studies easier and more accurate. This paper proposes a simple gait segmentation method based on plantar pressure measurement. Current methods used by researchers and clinicians are based on multiple sensing devices (e.g., multiple cameras, multiple inertial measurement units (IMUs)). Our proposal uses plantar pressure information from only two sensorized insoles that were designed and implemented with eight custom-made flexible capacitive sensors. An algorithm was implemented to calculate gait parameters and segment gait cycle phases and subphases. Functional tests were performed in six healthy volunteers in a 10 m walking test. The designed in-shoe insole presented an average power consumption of 44 mA under operation. The system segmented the gait phases and sub-phases in all subjects. The calculated percentile distribution between stance phase time and swing phase time was almost 60%/40%, which is aligned with literature reports on healthy subjects. Our results show that the system achieves a successful segmentation of gait phases and subphases, is capable of reporting COP velocity, double support time, cadence, stance phase time percentage, swing phase time percentage, and double support time percentage. The proposed system allows for the simplification of the assessment method in the recovery process for both patients and clinicians.
引用
收藏
页数:15
相关论文
共 40 条
[11]  
Chen M., 2008, P IEEE INT C ROB AUT
[12]  
De Rossi S., 2011, P 33 ANN INT C IEEE
[13]  
EMFIT Ltd, 2003, EMFIT FILM SPEC REV
[14]   Using smart garments to differentiate among normal and simulated abnormal gaits [J].
Esfahani, Mohammad Iman Mokhlespour ;
Nussbaum, Maury A. .
JOURNAL OF BIOMECHANICS, 2019, 93 :70-76
[15]   Using a smart textile system for classifying occupational manual material handling tasks: evidence from lab-based simulations [J].
Esfahani, Mohammad Iman Mokhlespour ;
Nussbaum, Maury A. ;
Kong, Zhenyu .
ERGONOMICS, 2019, 62 (06) :823-833
[16]   Preferred Placement and Usability of a Smart Textile System vs. Inertial Measurement Units for Activity Monitoring [J].
Esfahani, Mohammad Iman Mokhlespour ;
Nussbaum, Maury A. .
SENSORS, 2018, 18 (08)
[17]  
Gonzalez F.A., 2011, 10 C NACL MEC AS MEX
[18]  
Hessert Mary Josephine, 2005, BMC Geriatr, V5, P8
[19]   Textile Pressure Sensors for Sports Applications [J].
Holleczek, Thomas ;
Rueegg, Alex ;
Harms, Holger ;
Troester, Gerhard .
2010 IEEE SENSORS, 2010, :732-737
[20]   CAPACITIVE SENSORS FOR MEASURING THE PRESSURE BETWEEN THE FOOT AND SHOE [J].
KOTHARI, M ;
WEBSTER, JG ;
TOMPKINS, WJ ;
WERTSCH, JJ ;
BACHYRITA, P .
PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, :805-806