The Direct Incorporation of Perfusion Defect Information to Define Ischemia and Infarction in a Finite Element Model of the Left Ventricle

被引:7
|
作者
Veress, Alexander I. [1 ]
Fung, George S. K. [2 ]
Lee, Taek-Soo [2 ]
Tsui, Benjamin M. W. [2 ]
Kicska, Gregory A. [3 ]
Segars, W. Paul [4 ]
Gullberg, Grant T. [5 ]
机构
[1] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21287 USA
[3] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[4] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[5] Ernest Orlando Lawrence Berkeley Natl Lab, Struct Biol & Imaging Dept, Berkeley, CA 94720 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2015年 / 137卷 / 05期
关键词
cardiac imaging research; finite element; left ventricle; NCAT; XCAT; SPECT phantom; ischemia; myocardial infarction; mechanical model; EXPERIMENTAL MYOCARDIAL-INFARCTION; ACUTE REGIONAL ISCHEMIA; CARDIAC-HYPERTROPHY; BORDER ZONE; MECHANICS; HEART; SIZE; RESTORATION; DYSFUNCTION; PRESSURE;
D O I
10.1115/1.4028989
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper describes the process in which complex lesion geometries (specified by computer generated perfusion defects) are incorporated in the description of nonlinear finite element (FE) mechanical models used for specifying the motion of the left ventricle (LV) in the 4D extended cardiac torso (XCAT) phantom to simulate gated cardiac image data. An image interrogation process was developed to define the elements in the LV mesh as ischemic or infarcted based upon the values of sampled intensity levels of the perfusion maps. The intensity values were determined for each of the interior integration points of every element of the FE mesh. The average element intensity levels were then determined. The elements with average intensity values below a user-controlled threshold were defined as ischemic or infarcted depending upon the model being defined. For the infarction model cases, the thresholding and interrogation process were repeated in order to define a border zone (BZ) surrounding the infarction. This methodology was evaluated using perfusion maps created by the perfusion cardiac-torso (PCAT) phantom an extension of the 4D XCAT phantom. The PCAT was used to create 3D perfusion maps representing 90% occlusions at four locations (left anterior descending (LAD) segments 6 and 9, left circumflex (LCX) segment 11, right coronary artery (RCA) segment 1) in the coronary tree. The volumes and shapes of the defects defined in the FE mechanical models were compared with perfusion maps produced by the PCAT. The models were incorporated into the XCAT phantom. The ischemia models had reduced stroke volume (SV) by 18-59 ml. and ejection fraction (EF) values by 14-50% points compared to the normal models. The infarction models, had less reductions in SV and EF, 17-54 ml. and 14-45% points, respectively. The volumes of the ischemic/infarcted regions of the models were nearly identical to those volumes obtained from the perfusion images and were highly correlated (R-2 = 0.99).
引用
收藏
页数:10
相关论文
共 12 条
  • [1] Incorporation of a Left Ventricle Finite Element Model Defining Infarction Into the XCAT Imaging Phantom
    Veress, Alexander I.
    Segars, W. Paul
    Tsui, Benjamin M. W.
    Gullberg, Grant T.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (04) : 915 - 927
  • [2] Electromechanical feedback with reduced cellular connectivity alters electrical activity in an infarct injured left ventricle: a finite element model study
    Wall, Samuel T.
    Guccione, Julius M.
    Ratcliffe, Mark B.
    Sundnes, Joakim S.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2012, 302 (01): : H206 - H214
  • [3] Effect of Adjustable Passive Constraint on the Failing Left Ventricle: A Finite-Element Model Study
    Jhun, Choon-Sik
    Wenk, Jonathan F.
    Zhang, Zhihong
    Wall, Samuel T.
    Sun, Kay
    Sabbah, Hani N.
    Ratcliffe, Mark B.
    Guccione, Julius M.
    ANNALS OF THORACIC SURGERY, 2010, 89 (01) : 132 - +
  • [4] Microstructure-based finite element model of left ventricle passive inflation
    Xi, Ce
    Kassab, Ghassan S.
    Lee, Lik Chuan
    ACTA BIOMATERIALIA, 2019, 90 : 241 - 253
  • [5] Regional Left Ventricular Myocardial Contractility and Stress in a Finite Element Model of Posterobasal Myocardial Infarction
    Wenk, Jonathan F.
    Sun, Kay
    Zhang, Zhihong
    Soleimani, Mehrdad
    Ge, Liang
    Saloner, David
    Wallace, Arthur W.
    Ratcliffe, Mark B.
    Guccione, Julius M.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (04):
  • [6] Quasi-static image-based immersed boundary-finite element model of left ventricle under diastolic loading
    Gao, Hao
    Wang, Huiming
    Berry, Colin
    Luo, Xiaoyu
    Griffith, Boyce E.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2014, 30 (11) : 1199 - 1222
  • [7] The construction of three-dimensional composite finite element mechanical model of human left ventricle
    Liu, F
    Lu, WX
    Xia, L
    Wu, GH
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2001, 44 (01) : 125 - 133
  • [8] First Finite Element Model of the Left Ventricle With Mitral Valve: Insights Into Ischemic Mitral Regurgitation
    Wenk, Jonathan F.
    Zhang, Zhihong
    Cheng, Guangming
    Malhotra, Deepak
    Acevedo-Bolton, Gabriel
    Burger, Mike
    Suzuki, Takamaro
    Saloner, David A.
    Wallace, Arthur W.
    Guccione, Julius M.
    Ratcliffe, Mark B.
    ANNALS OF THORACIC SURGERY, 2010, 89 (05) : 1546 - 1554
  • [9] A microstructure-based finite element model of the human left ventricle for simulating the trans-scale myocardial mechanical behaviors
    Liu, Taiwei
    Liang, Fuyou
    MECHANICS OF MATERIALS, 2025, 203
  • [10] Estimation of mechanical properties from gated SPECT and Cine MRI data using a finite-element mechanical model of the left ventricle
    Feng, B
    Veress, AI
    Sitek, A
    Gullberg, GT
    Roy, DG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 725 - 733