Activity-dependence of the "safe zone" for impingement versus dislocation avoidance

被引:56
作者
Pedersen, DR [1 ]
Callaghan, JJ [1 ]
Brown, TD [1 ]
机构
[1] Univ Iowa, Dept Biomed Engn, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USA
关键词
dislocation; small head; hip arthroplasty; impingement;
D O I
10.1016/j.medengphy.2004.09.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Presently, the basis for optimal cup positioning to minimize the likelihood of dislocation rests upon subjective clinical impressions. To help elucidate optimal cup positioning more objectively, and to clarify the distinction between impingement avoidance and dislocation avoidance, kinematic and kinetic inputs for seven dislocation-prone activities were applied to finite element models of a contemporary 22-mm modular total hip reconstruction. Twenty-five cup placement positions (combinations of 30, 40, 50, 60, and 70° of abduction with 0, 10, 20, 30, and 40° of anteversion) were chosen to include the conventional 'safe zone' of 30-50° of tilt and 5-25° of anteversion. Activities studied were: rising from a low seat (toilet) and from a normal height chair, leg-crossing while seated, tying a shoe from a seated position, bending at the hip from an erect stance to retrieve an object on the floor (stooping), a standing pivot maneuver, and rolling over in bed. Neck-on-cup impingement occurred during one or more of the dislocation-prone activities at all 25 cup positions. Of the 175 combinations of cup position and kinetic challenge, dislocation and impingement events both occurred for 51 situations, while impingement occurred in 45 instances without dislocation, and dislocation occurred in 10 instances without impingement. Neither dislocation nor impingement was observed in the 69 other combinations of cup position and loading challenge. Kappa statistics showed dislocation and impingement, as outcome measures of activity-dependent challenges, exhibit little more than chance agreement. Therefore, the use of impingement range of motion (ROM) as a predictor of a given cup position's vulnerability to dislocation should be viewed cautiously. © 2004 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 14 条
[1]   Computer-based motion simulation of total hip prostheses with ceramic-on-ceramic wear couple. Analysis of implant design and orientation as influence parameters [J].
Bader, R ;
Steinhauser, E ;
Gradinger, R ;
Willmann, G ;
Mittelmeier, W .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2002, 140 (03) :310-316
[2]   Ceramic acetabular cups for total hip replacement - Part 6: Cup design, inclination angle and antetorsion angle have an influence on the range of motion and impingement [J].
Bader, R ;
Willmann, G .
BIOMEDIZINISCHE TECHNIK, 1999, 44 (7-8) :212-219
[3]  
Barrack Robert L, 2003, J Am Acad Orthop Surg, V11, P89
[4]  
CRIPTON P, 1993, COMPRESSIVE CHARACTE
[5]  
HERRLIN K, 1988, ACTA RADIOL, V29, P441
[6]  
HERRLIN K, 1988, ACTA RADIOL, V29, P551
[7]   The effect of acetabular cup orientations on limiting hip rotation [J].
Kummer, FJ ;
Shah, S ;
Iyer, S ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 1999, 14 (04) :509-513
[8]  
KURTZ SM, 1995, THESIS CORNELL U ITH
[9]  
MCCOLLUM DE, 1990, CLIN ORTHOP RELAT R, P159
[10]   Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation [J].
Nadzadi, ME ;
Pedersen, DR ;
Yack, HJ ;
Callaghan, JJ ;
Brown, TD .
JOURNAL OF BIOMECHANICS, 2003, 36 (04) :577-591