Detecting Four-Limb Blood Oxygen Saturation and Heart Rate based on Reflex Photoplethysmography

被引:1
作者
Lu, Chi-Heng [1 ]
Wei, Jhao-En [1 ]
Tuan, Chiu-Ching [1 ]
机构
[1] Natl Taipei Univ Technol, Grad Inst Elect Engn, 1,Sec 3,Zhongxiao E Rd, Taipei 10608, Taiwan
来源
2018 2ND INTERNATIONAL CONFERENCE ON E-SOCIETY, E-EDUCATION AND E-TECHNOLOGY (ICSET 2018) | 2018年
关键词
Photoplethysmography; Four-Limb; Oxygen Saturation; Heart Rate; Hyperbaric Oxygen Therapy; Vascular suture; NEAR-INFRARED SPECTROSCOPY;
D O I
10.1145/3268808.3268822
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The study purpose is to construct a reflective Oxygen Saturation (SpO(2)) and Heart Rate (HR) four-limb detective device, improve transmission SpO(2) device only to measure finger, toe and earlobe. Using Silicon Labs Si1143, Arduino Nano, self-calibrated SpO(2) algorithm and mobile application software constitute a mobile reflective SpO(2) and HR detective device. Static four parts and post-exercise experiment had been carried out to test our device, the result can achieve comparable performance to a clinical device with no significant difference revealed by paired t-tests. This study has applied for clinical trial permission, the schedule will improve the calibration curve and compensation factor of unverifiable body parts by blood draw comparison. Provide clinical staff for immediate local SpO(2) and HR information, evaluate the effectiveness of vascular suture and hyperbaric oxygen therapy.
引用
收藏
页码:145 / 149
页数:5
相关论文
共 15 条
  • [1] Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion
    Abay, Tomas Ysehak
    Kyriacou, Panayiotis A.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (09) : 2187 - 2195
  • [2] Allen J, 2004, IEEE COMPUT CARDIOL, V2004, P485
  • [3] Comparison of SpO2 values from different fingers of the hands
    Basaranoglu, Gokcen
    Bakan, Mefkur
    Umutoglu, Tarik
    Zengin, Seniyye Ulgen
    Idin, Kadir
    Salihoglu, Ziya
    [J]. SPRINGERPLUS, 2015, 4
  • [4] A Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection
    He, Diwei
    Morgan, Stephen P.
    Trachanis, Dimitrios
    van Hese, Jan
    Drogoudis, Dimitris
    Fummi, Franco
    Stefanni, Francesco
    Guarnieri, Valerio
    Hayes-Gill, Barrie R.
    [J]. SENSORS, 2015, 15 (07): : 17076 - 17088
  • [5] Pulse oximetry in the oesophagus
    Kyriacou, PA
    [J]. PHYSIOLOGICAL MEASUREMENT, 2006, 27 (01) : R1 - R35
  • [6] A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors
    Lin, Shu-Tyng
    Chen, Wei-Hao
    Lin, Yuan-Hsiang
    [J]. SENSORS, 2017, 17 (07):
  • [7] A Prototype of Reflection Pulse Oximeter Designed for Mobile Healthcare
    Lu, Zhiyuan
    Chen, Xiang
    Dong, Zhongfei
    Zhao, Zhangyan
    Zhang, Xu
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (05) : 1309 - 1320
  • [8] Near-infrared spectroscopy: A methodology-focused review
    Pellicer, Adelina
    del Carmen Bravo, Maria
    [J]. SEMINARS IN FETAL & NEONATAL MEDICINE, 2011, 16 (01) : 42 - 49
  • [9] RUSCH TL, 1994, PROCEEDINGS OF THE 16TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY - ENGINEERING ADVANCES: NEW OPPORTUNITIES FOR BIOMEDICAL ENGINEERS, PTS 1&2, P848, DOI 10.1109/IEMBS.1994.415177
  • [10] Measuring tissue hemodynamics and oxygenation by continuous-wave functional near-infrared spectroscopy-how robust are the different calculation methods against movement artifacts?
    Scholkmann, Felix
    Metz, Andreas Jaakko
    Wolf, Martin
    [J]. PHYSIOLOGICAL MEASUREMENT, 2014, 35 (04) : 717 - 734