Diagnostic accuracy of gynecology imaging reporting and data system in evaluation of adnexal lesions

被引:6
作者
Behnamfar, Fariba [1 ]
Adibi, Atoosa [2 ]
Khadra, Hiba [2 ]
Moradi, Maryam [2 ]
机构
[1] Isfahan Univ Med Sci, Med Sch, Dept Obstet & Gynecol, Esfahan, Iran
[2] Isfahan Univ Med Sci, Med Sch, Dept Radiol, Esfahan, Iran
来源
JOURNAL OF RESEARCH IN MEDICAL SCIENCES | 2019年 / 24卷
关键词
Adnexal diseases; ovarian neoplasms; ultrasonography; PELVIC MASSES; ULTRASOUND; MANAGEMENT; OVARIAN; BENIGN;
D O I
10.4103/jrms.JRMS_608_18
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Considering the increasing incidence rate of ovarian cancer in worldwide and the utility of Gynecologic Imaging Reporting and Data System (GI-RADS) in diagnosing malignant adnexal lesions such as ovarian cancer, we aimed to evaluate the diagnostic performance of this reporting system in differentiating between malignant and benign adnexal lesions. Materials and Methods: In this cross-sectional study, women with suspected adnexal lesions were enrolled. For differentiating of malignant adnexal lesions, Grade II and III of GI-RADS system were classified as low risk for malignancy and Grades IV and V as high risk. Results of histopathologic diagnosis were compared with the results of the mentioned GI-RADS system classification, and the diagnosed accuracy of the system was determined. Patients who did not have histopathologic diagnosis were followed up. Results: In this study, 197 women with suspected adnexal lesions were evaluated. Frequency of GI-RADS II, III, IV, and V were 34.5% (69 cases), 38.0% (76 cases), 19.5% (39 cases), and 6.5% (13 cases), respectively. According to the low- and high-risk classification of GI-RADS, 72.5% were classified as GI-RADS II and III and 26% as GI-RADS IV and V, respectively. Definitive histopathologic diagnosis was reported for 158 cases. Histopathologic evaluation indicated that 12 (7.6%) of the masses were malignant and 146 (92.6%) were benign. Comparing with the histopathologic diagnosis, the GI-RADS system sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio (LR), and negative LR were 91.6%, 80.82%, 28.2%, 99.1%, 4.77, and 0.10, respectively. The accuracy of the scoring system was 81.64%. Conclusion: Our findings indicated that using GI-RADS, we could quantify the risk of malignancy by such a structured as well as simple reporting system so that the system could be useful for clinicians for performing an appropriate clinical management.
引用
收藏
页数:7
相关论文
共 24 条
[1]   A new scoring system to differentiate benign from malignant adnexal masses [J].
Alcázar, JL ;
Mercé, LT ;
Laparte, C ;
Jurado, M ;
López-García, G .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 188 (03) :685-692
[2]  
Alcázar JL, 2001, J ULTRAS MED, V20, P841
[3]   GI-RADS reporting system for ultrasound evaluation of adnexal masses in clinical practice: a prospective multicenter study [J].
Amor, F. ;
Alcazar, J. L. ;
Vaccaro, H. ;
Leon, M. ;
Iturra, A. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 38 (04) :450-455
[4]   Gynecologic Imaging Reporting and Data System A New Proposal for Classifying Adnexal Masses on the Basis of Sonographic Findings [J].
Amor, Fernando ;
Vaccaro, Humberto ;
Luis Alcazar, Juan ;
Leon, Mauricio ;
Manuel Craig, Jose ;
Martinez, Jaime .
JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (03) :285-291
[5]  
[Anonymous], 1994, Gynecol Oncol, V55, pS4
[6]  
[Anonymous], US CANC STAT 1999 20
[7]  
Biggs WS, 2016, AM FAM PHYSICIAN, V93, P676
[8]  
Brown Douglas L, 2007, Ultrasound Q, V23, P87, DOI 10.1097/01.ruq.0000263849.45926.cb
[9]   Adnexal Masses: US Characterization and Reporting [J].
Brown, Douglas L. ;
Dudiak, Kika M. ;
Laing, Faye C. .
RADIOLOGY, 2010, 254 (02) :342-354
[10]   Preoperative identification of a suspicious adnexal mass: A systematic review and meta-analysis [J].
Dodge, Jason E. ;
Covens, Allan L. ;
Lacchetti, Christina ;
Elit, Laurie M. ;
Le, Tien ;
Devries-Aboud, Michaela ;
Fung-Kee-Fung, Michael .
GYNECOLOGIC ONCOLOGY, 2012, 126 (01) :157-166