Experience With a Long-term Pulsatile Ventricular Assist Device as a Bridge to Heart Transplant in Adults

被引:0
作者
Gomez Bueno, Manuel [1 ,2 ]
Segovia Cubero, Javier [1 ,2 ]
Serrano Fiz, Santiago [3 ]
Ugarte Basterrechea, Juan [3 ]
Hernandez Perez, Francisco Jose [1 ]
Goirigolzarri Artaza, Josebe [1 ]
Castedo Mejuto, Evaristo [3 ]
Burgos Lazaro, Raul [3 ]
Garcia Montero, Carlos [3 ]
Monivas Palomero, Vanessa [1 ]
Mingo Santos, Susana [1 ]
Gonzalez Roman, Ana Isabel [4 ]
Alvarez Avello, Jose Manuel [4 ]
Vidal Fernandez, Mercedes [4 ]
Forteza Gil, Alberto [3 ]
Alonso-Pulpon, Luis [1 ,2 ]
机构
[1] Hosp Univ Puerta de Hierro, Serv Cardiol, Madrid, Spain
[2] CIBER Enfermedades Cardiovasc CIBERCV, Madrid, Spain
[3] Hosp Univ Puerta de Hierro, Serv Cirugia Cardiaca, Madrid, Spain
[4] Hosp Univ Puerta de Hierro, Serv Anestesia & Reanimac, Madrid, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2017年 / 70卷 / 09期
关键词
Heart failure; Ventricular assist device; Heart transplant; SUPPORT; FAILURE;
D O I
10.1016/j.recesp.2016.11.043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: Most long-term ventricular assist devices (VADs) that are currently implanted are intracorporeal continuous-flow devices. Their main limitations include their high cost and inability to provide biventricular support. The aim of this study was to describe the results of using paracorporeal pulsatile-flow VADs as a bridge to transplant (BTT) in adult patients. Methods: Retrospective analysis of the characteristics, complications, and outcomes of a single-center case series of consecutive patients treated with the EXCOR VAD as BTT between 2009 and 2015. Results: During the study period, 25 VADs were implanted, 6 of them biventricular. Ventricular assist devices were indicated directly as a BTT in 12 patients and as a bridge to decision in 13 due to the presence of potentially reversible contraindications or chance of heart function recovery. Twenty patients (80%) were successfully bridged to heart transplant after a median of 112 days (range, 8-239). The main complications included infectious (52% of patients), neurological events (32%, half of them fatal), bleeding (28%), and VAD malfunction requiring component replacement (28%). Conclusions: Eighty percent of patients with the EXCOR VAD as BIT achieved the goal after an average of almost 4 months of support. The most frequent complications were infectious, and the most severe were neurological. In our enivonment, the use of these pulsatile-flow VAD as BTT is a feasible strategy that obtains similar outcomes to those of intracorporeal continuous-flow devices. Full English text available from: www.revespcardiol.org/en (C) 2016 Sociedad Espanola de Cardiologla. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:727 / 735
页数:9
相关论文
共 13 条
  • [1] Impact of short-termmechanical circulatory support with extracorporeal devices on postoperative outcomes after emergency heart transplantation: Data from a multi-institutional Spanish cohort
    Barge-Caballero, Eduardo
    Almenar-Bonet, Luis
    Villa-Arranz, Adolfo
    Perez-Villa, Felix
    Segovia-Cubero, Javier
    Delgado-Jimenez, Juan
    Gonzalez-Vilchez, Francisco
    Manito-Lorite, Nicolas
    De-la-Fuente-Galan, Luis
    Brossa-Loidi, Vicens
    Lambert-Rodriguez, Jose L.
    Pascual-Figal, Domingo
    Lage-Galle, Ernesto
    Arizon-Del-Prado, Jose M.
    Sanz-Julve, Marisa
    Muniz-Garcia, Javier
    Crespo-Leiro, Marisa
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 176 (01) : 86 - 93
  • [2] The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): first annual report
    de By, Theo M. M. H.
    Mohacsi, Paul
    Gummert, Jan
    Bushnaq, Hasan
    Krabatsch, Thomas
    Gustafsson, Finn
    Leprince, Pascal
    Martinelli, Luigi
    Meyns, Bart
    Morshuis, Michiel
    Netuka, Ivan
    Potapov, Evgenij
    Zittermann, Armin
    Walter, Eva Maria Delmo
    Hetzer, Roland
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (05) : 770 - 777
  • [3] Successful heart transplantation after Berlin-Heart EXCOR biventricular assist device in adult patients
    Diez-Villanueva, Pablo
    Sousa, Lago
    Ruiz, Manuel
    Hortal, Javier
    Gonzalez-Pinto, Angel
    Fernandez-Aviles, Francisco
    [J]. CIRUGIA CARDIOVASCULAR, 2016, 23 (02): : 104 - 106
  • [4] EXCOR Adult Update, WORLDW CLIN EXP EXC
  • [5] Garcia-Cosio Carmena M Dolores, 2013, Rev Esp Cardiol (Engl Ed), V66, P400, DOI 10.1016/j.rec.2011.06.016
  • [6] A Serious Complication in a Patient With a Ventricular Assist Device
    Hernandez-Perez, Francisco J.
    Burgos-Lazaro, Raul J.
    Gomez-Bueno, Manuel F.
    [J]. REVISTA ESPANOLA DE CARDIOLOGIA, 2014, 67 (04): : 322 - 322
  • [7] Seventh INTERMACS annual report: 15,000 patients and counting
    Kirklin, James K.
    Naftel, David C.
    Pagani, Francis D.
    Kormos, Robert L.
    Stevenson, Lynne W.
    Blume, Elizabeth D.
    Myers, Susan L.
    Miller, Marissa A.
    Baldwin, J. Timothy
    Young, James B.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12) : 1495 - 1504
  • [8] Right ventricular failure after left ventricular assist devices
    Lampert, Brent C.
    Teuteberg, Jeffrey J.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (09) : 1123 - 1130
  • [9] Organization Nacional de Trasplantes, GOB DE ESP
  • [10] Long-Term Paracorporeal Ventricular Support Systems: A Single-Center Experience
    Ozbaran, M.
    Yagdi, T.
    Engin, C.
    Erkul, S.
    Balcioglu, O.
    Baysal, B.
    Nalbantgil, S.
    Ertugay, S.
    [J]. TRANSPLANTATION PROCEEDINGS, 2013, 45 (03) : 1013 - 1016