Contasure-NeedlelessA® single incision sling compared with transobturator TVT-O A® for the treatment of stress urinary incontinence: long-term results

被引:23
|
作者
Martinez Franco, Eva [1 ]
Amat Tardiu, Lluis [1 ]
机构
[1] Hosp St Joan de Deu, Pelv Floor Unit, Dept Obstet & Gynaecol, Esplugas de Llobregat 08950, Barcelona, Spain
关键词
Mini-sling; Needleless; Single incision tape; Stress urinary incontinence; TVT; FREE VAGINAL TAPE; MIDURETHRAL SLINGS; SURGICAL-MANAGEMENT; SUBURETHRAL TAPE; FOLLOW-UP; MULTICENTER; OBTURATOR; OUTCOMES; WOMEN;
D O I
10.1007/s00192-014-2475-x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
This study compared transobturator tension-free vaginal tape (TVT-OA (R)) and Contasure-Needleless (C-NDLA (R)) at long-term follow-up . Non-inferiority, prospective, single-centre , quasi-randomised trial started in September 2006 and finished in April 2011 to compare C-NDL A (R) with transobturator vaginal tape (TVT-OA (R)) mesh in the treatment of stress urinary incontinence (SUI) . Epidemiological information, intraoperative and postoperative complications, subjective estimates of blood loss and pain levels were recorded. We also analysed the postoperative stress test, the subjective impression of improvement using the Sandvik Severity Index and the quality of life during follow-up using the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) . Two hundred and fifty-seven women with primary SUI were scheduled to receive TVT-O A (R) or C-NDL A (R) and were followed up at least 3 years after the procedure . One hundred and eleven women in the C-NDL A (R) group (84.7 %) had a negative stress test, compared with 54 women (88.9 %) in the TVT-O A (R) group (p = 0.0065 for the non-inferiority test). The postoperative Sandvik Severity Index was 0 or better than the preoperative score in 90.7 % of patients in the C-NDL A (R) group and 95.4 % of patients in the TVT-O A (R) group (p = 0.0022). The complication rate was similar in both groups. There were significant differences (p = 0.02) in postoperative pain within the TVT-O A (R) group. The degree of satisfaction was not statistically significant between the two groups. The outcomes for the C-NDL A (R) group were similar to those of the TVT-O A (R) group, adding the concept of "single incision tape" to the tension-free sling option.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [1] Contasure-Needleless® single incision sling compared with transobturator TVT-O ® for the treatment of stress urinary incontinence: long-term results
    Eva Martinez Franco
    Lluís Amat Tardiu
    International Urogynecology Journal, 2015, 26 : 213 - 218
  • [2] Contasure-NeedlelessA® compared with transobturator-TVTA® for the treatment of stress urinary incontinence
    Amat i Tardiu, Lluis
    Martinez Franco, Eva
    Lailla Vicens, Josep Maria
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2011, 22 (07) : 827 - 833
  • [3] Contasure-needlelessA® compared with MonarcA® for the treatment of stress urinary incontinence
    Fernandez-Gonzalez, Sergi
    Martinez Franco, Eva
    Miao, Xinxin Lin
    Amat Tardiu, Lluis
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2017, 28 (07) : 1077 - 1084
  • [4] Contasure-Needleless® compared with transobturator-TVT® for the treatment of stress urinary incontinence
    Lluís Amat i Tardiu
    Eva Martínez Franco
    Josep Maria Laïlla Vicens
    International Urogynecology Journal, 2011, 22 : 827 - 833
  • [5] Contasure-needleless single incision slings versus transobturator slings (TOT/TVT-O) for female patients with stress urinary incontinence: a systematic review and meta-analysis
    Luo, Zhenkai
    Jiao, Binbin
    Zhao, Hang
    Liu, Hailong
    Lai, Shicong
    Zhang, Guan
    BMC UROLOGY, 2020, 20 (01)
  • [6] Single-incision sling compared with transobturator sling for treating stress urinary incontinence: a randomized controlled trial
    Bianchi-Ferraro, Ana Maria H. M.
    Jarmy-Di Bella, Zsuzsanna I. K.
    Castro, Rodrigo de A.
    Bortolini, Maria Augusta T.
    Sartori, Marair G. F.
    Girao, Manoel J. B. C.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2013, 24 (09) : 1459 - 1465
  • [7] A randomized comparison of a single-incision needleless (Contasure-needlelessA®) mini-sling versus an inside-out transobturator (Contasure-KIMA®) mid-urethral sling in women with stress urinary incontinence: 24-month follow-up results
    Dogan, Ozan
    Kaya, Aski Ellibes
    Pulatoglu, Cigdem
    Basbug, Alper
    Yassa, Murat
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2018, 29 (09) : 1387 - 1395
  • [8] Long-term outcomes of the AjustA® Adjustable Single-Incision Sling for the treatment of stress urinary incontinence
    Naumann, Gert
    Hagemeier, Thomas
    Zachmann, Stefan
    Al-Ani, Aktham
    Albrich, Stefan
    Skala, Christine
    Laterza, Rosa
    Linaberry, Misti
    Koelbl, Heinz
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2013, 24 (02) : 231 - 239
  • [9] Transobturator Sling Compared With Single-Incision Mini-Sling for the Treatment of Stress Urinary Incontinence A Randomized Controlled Trial
    Djehdian, Lucyana M.
    Araujo, Maita P.
    Takano, Claudia C.
    Del-Roy, Carlos A.
    Sartori, Marair G. F.
    Girao, Manoel J. B. C.
    Castro, Rodrigo A.
    OBSTETRICS AND GYNECOLOGY, 2014, 123 (03) : 553 - 561
  • [10] Evaluation of the efficacy and safety of single incision sling vs TVT-O in obese patients with stress urinary incontinence: Quality of life and sexual function analysis
    Schiavi, Michele Carlo
    Carletti, Valerio
    Yacoub, Veronica
    Cardella, Giorgia
    Luffarelli, Paolo
    Valensise, Herbert Carmelo Carlo
    Palazzetti, Pierluigi
    Spina, Vincenzo
    Zullo, Marzio Angelo
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2023, 62 (01): : 89 - 93