Observer reliability in evaluating pedicle screw placement using computed tomography

被引:28
作者
Kosmopoulos, Victor
Theumann, Nicolas
Binaghi, Stefano
Schizas, Constantin
机构
[1] Hop Orthoped Suisse Romande, Dept Orthopaed, CH-1005 Lausanne, Switzerland
[2] CHU Vaudois, Dept Radiol, CH-1011 Lausanne, Switzerland
关键词
D O I
10.1007/s00264-006-0230-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Pedicle screw insertion in spinal surgery is a demanding technique with potential risks to neurological structures, for example, within the spinal canal. Assessing screw placement in clinical practice has been performed using plain radiographs and/or mainly axial computed tomography (CT) images. Screw placement using CT image reconstructions in multiple planes has been described, but its reliability has yet to be studied. This study aimed at addressing the clinical issue of interobserver and intraobserver reliability in the use of axial and coronal CT images for the assessment of pedicle screw placement. Fifty nine pedicle screws were studied by two experienced radiologists on two separate occasions. Screw placement was classified as "in", "out" or "questionable". On average, 88% and 92% of the screws were classified as "in" by the first and second radiologist, respectively. Intraobserver agreement strength was almost perfect for both observers using either axial or coronal images. Interobserver agreement strength was almost perfect (axial) and substantial (coronal) in the first reading and substantial (axial, coronal) in the second reading. Assessing screw placement in more than one CT imaging plane is not only useful but reliable. Routine use may enhance reporting quality of screw placement by surgeons and radiologists.
引用
收藏
页码:531 / 536
页数:6
相关论文
共 31 条
  • [1] One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems
    Abumi, K
    Kaneda, K
    Shono, Y
    Fujiya, M
    [J]. JOURNAL OF NEUROSURGERY, 1999, 90 (01) : 19 - 26
  • [2] Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique
    Boachie-Adjei, O
    Girardi, FP
    Bansal, M
    Rawlins, BA
    [J]. JOURNAL OF SPINAL DISORDERS, 2000, 13 (06): : 496 - 500
  • [3] Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries - Technique and short-term complications
    Carbone, JJ
    Tortolani, J
    Quartararo, LG
    [J]. SPINE, 2003, 28 (01) : 91 - 97
  • [4] In vivo pedicle screw placement: Image-guided virtual vision
    Carl, AL
    Khanuja, HS
    Gatto, CA
    Matsumoto, M
    vomLehn, J
    Schenck, J
    Rohling, K
    Lorensen, W
    Vosburgh, K
    [J]. JOURNAL OF SPINAL DISORDERS, 2000, 13 (03): : 225 - 229
  • [5] Accuracy of pedicle screw placement in lumbar vertebrae
    Castro, WHM
    Halm, H
    Jerosch, J
    Malms, J
    Steinbeck, J
    Blasius, S
    [J]. SPINE, 1996, 21 (11) : 1320 - 1324
  • [6] ACCURACY OF PEDICLE SCREW PLACEMENT IN LUMBAR FUSIONS BY PLAIN RADIOGRAPHS AND COMPUTED-TOMOGRAPHY
    FARBER, GL
    PLACE, HM
    MAZUR, RA
    JONES, DEC
    DAMIANO, TR
    [J]. SPINE, 1995, 20 (13) : 1494 - 1499
  • [7] Accuracy of computed tomography in assessing thoracic pedicle screw malposition
    Fayyazi, AH
    Hugate, RR
    Pennypacker, J
    Gelb, DE
    Ludwig, SC
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (05): : 367 - 371
  • [8] Reliability of roentgenogram evaluation of pedicle screw position
    Ferrick, MR
    Kowalski, JM
    Simmons, ED
    [J]. SPINE, 1997, 22 (11) : 1249 - 1252
  • [9] Fleiss JL., 2003, STAT METHODS RATES P, P598, DOI 10.1002/0471445428
  • [10] The placement of lumbar pedicle screws using computerised stereotactic guidance
    Girardi, FP
    Cammisa, FP
    Sandhu, HS
    Alvarez, L
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05): : 825 - 829