A new device for performing reference point indentation without a reference probe

被引:82
作者
Bridges, Daniel [1 ]
Randall, Connor [1 ]
Hansma, Paul K. [1 ,2 ]
机构
[1] Univ Calif Santa Barbara, Dept Phys, Santa Barbara, CA 93106 USA
[2] Act Life Sci Inc, Santa Barbara, CA 93111 USA
关键词
BONE; INSTRUMENT; AGE;
D O I
10.1063/1.3693085
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Here we describe a novel, hand-held reference point indentation (RPI), instrument that is designed for clinical measurements of bone material properties in living patients. This instrument differs from previous RPI instruments in that it requires neither a reference probe nor removal of the periosteum that covers the bone, thus significantly simplifying its use in patient testing. After describing the instrument, we discuss five guidelines for optimal and reproducible results. These are: (1) the angle between the normal to the surface and the axis of the instrument should be less than 10 degrees, (2) the compression of the main spring to trigger the device must be performed slowly (>1 s), (3) the probe tip should be sharper than 10 mu m; however, a normalized parameter with a calibration phantom can correct for dull tips up to a 100 mu m radius, (4) the ambient room temperature should be between 4 degrees C and 37 degrees C, and (5) the effective mass of the bone or material under test must exceed 1 kg, or if under 1 kg, the specimen should be securely anchored in a fixation device with sufficient mass (which is not a requirement of previous RPI instruments). Our experience is that a person can be trained with these guidelines in about 5 min and thereafter obtain accurate and reproducible results. The portability, ease of use, and minimal training make this instrument suitable to measure bone material properties in a clinical setting. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3693085]
引用
收藏
页数:8
相关论文
共 10 条
[1]   Insights into material and structural basis of bone fragility from diseases associated with fractures: How determinants of the biomechanical properties of bone are compromised by disease [J].
Chavassieux, P. ;
Seeman, E. ;
Delmas, P. D. .
ENDOCRINE REVIEWS, 2007, 28 (02) :151-164
[2]   CHANGES IN THE IMPACT ENERGY-ABSORPTION OF BONE WITH AGE [J].
CURREY, JD .
JOURNAL OF BIOMECHANICS, 1979, 12 (06) :459-&
[3]   Microindentation for In Vivo Measurement of Bone Tissue Mechanical Properties in Humans [J].
Diez-Perez, Adolfo ;
Guerri, Roberto ;
Nogues, Xavier ;
Caceres, Enric ;
Jesus Pena, Maria ;
Mellibovsky, Leonardo ;
Randall, Connor ;
Bridges, Daniel ;
Weaver, James C. ;
Proctor, Alexander ;
Brimer, Davis ;
Koester, Kurt J. ;
Ritchie, Robert O. ;
Hansma, Paul K. .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (08) :1877-1885
[4]   The bone diagnostic instrument II: Indentation distance increase [J].
Hansma, Paul ;
Turner, Patricia ;
Drake, Barney ;
Yurtsev, Eugene ;
Proctor, Alexander ;
Mathews, Phillip ;
Lelujian, Jason ;
Randall, Connor ;
Adams, Jonathan ;
Jungmann, Ralf ;
Garza-de-Leon, Federico ;
Fantner, Georg ;
Mkrtchyan, Haykaz ;
Pontin, Michael ;
Weaver, Aaron ;
Brown, Morton B. ;
Sahar, Nadder ;
Rossello, Ricardo ;
Kohn, David .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (06)
[5]   The tissue diagnostic instrument [J].
Hansma, Paul ;
Yu, Hongmei ;
Schultz, David ;
Rodriguez, Azucena ;
Yurtsev, Eugene A. ;
Orr, Jessica ;
Tang, Simon ;
Miller, Jon ;
Wallace, Joseph ;
Zok, Frank ;
Li, Cheng ;
Souza, Richard ;
Proctor, Alexander ;
Brimer, Davis ;
Nogues-Solan, Xavier ;
Mellbovsky, Leonardo ;
Pena, M. Jesus ;
Diez-Ferrer, Oriol ;
Mathews, Phillip ;
Randall, Connor ;
Kuo, Alfred ;
Chen, Carol ;
Peters, Mathilde ;
Kohn, David ;
Buckley, Jenni ;
Li, Xiaojuan ;
Pruitt, Lisa ;
Diez-Perez, Adolfo ;
Alliston, Tamara ;
Weaver, Valerie ;
Lotz, Jeffrey .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (05)
[6]   Bone diagnostic instrument [J].
Hansma, Paul K. ;
Turner, Patricia J. ;
Fantner, Georg E. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (07)
[7]  
Hvid I., 2000, PENETRATION TESTING
[8]   INDENTATION INSTRUMENT FOR THE MEASUREMENT OF CARTILAGE STIFFNESS UNDER ARTHROSCOPIC CONTROL [J].
LYYRA, T ;
JURVELIN, J ;
PITKANEN, P ;
VAATAINEN, U ;
KIVIRANTA, I .
MEDICAL ENGINEERING & PHYSICS, 1995, 17 (05) :395-399
[9]   Estimation of the Young's modulus of articular cartilage using an arthroscopic indentation instrument and ultrasonic measurement of tissue thickness [J].
Töyräs, J ;
Lyyra-Laitinen, T ;
Niinimäki, M ;
Lindgren, R ;
Nieminen, MT ;
Kiviranta, I ;
Jurvelin, JS .
JOURNAL OF BIOMECHANICS, 2001, 34 (02) :251-256
[10]   Age-dependent biomechanical modifications in bone [J].
Vashishth, D .
CRITICAL REVIEWS IN EUKARYOTIC GENE EXPRESSION, 2005, 15 (04) :343-357