Effects of adsorbent mass and number of adsorber beds on the performance of a waste heat-driven adsorption cooling system for vehicle air conditioning applications

被引:43
作者
Sharafian, Amir [1 ]
Mehr, Seyyed Mandi Nemati [1 ]
Thimmaiah, Poovanna Cheppudira [1 ]
Huttema, Wendell [1 ]
Bahrami, Majid [1 ]
机构
[1] Simon Fraser Univ, Lab Alternat Energy Convers, Sch Mechatron Syst Engn, Surrey, BC V3T 0A3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Adsorbent mass; FAM-Z02; Adsorber bed; Adsorption cooling system; Vehicle air conditioning; LOW-TEMPERATURE HEAT; SILICA GEL-WATER; SOLID SORPTION CHILLER; COMPOSITE ADSORBENT; ACTIVATED CARBON; THERMAL-CONDUCTIVITY; COMPOUND ADSORBENT; MONOLITHIC CARBON; MACHINE DRIVEN; REFRIGERATION;
D O I
10.1016/j.energy.2016.06.099
中图分类号
O414.1 [热力学];
学科分类号
摘要
Waste heat-driven adsorption cooling systems (ACS) are potential replacements for vapor compression refrigeration cycles in vehicle air conditioning applications. However, the bulkiness and heavy weight of ACS are major challenges facing commercialization of these environmentally friendly systems. This study examines the effects of adsorbent mass and the number of adsorber beds on the performance of a FAM-Z02/water ACS under different operating conditions. The experimental results show that reducing the mass of FAM-Z02 from 1.9 to 0.5 kg in a one-adsorber bed ACS increases the SCP by 82% from 65.8 to 119.4 W/kg at cycle time of 20 min. However, the COP reduces by 37% because of the increase in the adsorber bed to adsorbent mass ratio. The results also show that the thermal mass of the evaporator limits the performance of the ACS, especially under short cycle times (8-20 min). A second adsorber bed is added to the one-adsorbed bed ACS test bed to generate continuous cooling in the evaporator. Comparing the performance of one- and two-adsorber bed ACS packed with 0.5 kg of FAM-Z02 particles and cycle time of 20 min shows that the SCP and COP of the two-adsorber bed ACS increase by 28% and 47%, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:481 / 493
页数:13
相关论文
共 78 条
[41]  
Okamoto K, 2010, INT S INN MAT PROC E
[42]   Making adsorptive chillers faster by a proper choice of adsorption isobar shape: Comparison of optimal and real adsorbents [J].
Okunev, Boris N. ;
Aristov, Yuri I. .
ENERGY, 2014, 76 :400-405
[43]   Experimental investigation of an adsorption refrigeration prototype with the working pair of composite adsorbent-ammonia [J].
Pan, Q. W. ;
Wang, R. Z. ;
Lu, Z. S. ;
Wang, L. W. .
APPLIED THERMAL ENGINEERING, 2014, 72 (02) :275-282
[44]   Experimental tests and predictive model of an adsorptive air conditioning unit [J].
Poyelle, F ;
Guilleminot, JJ ;
Meunier, F .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (01) :298-309
[45]   Experimental investigation of a solid adsorption chiller based on a heat exchanger coated with hydrophobic zeolite [J].
Restuccia, G ;
Freni, A ;
Russo, F ;
Vasta, S .
APPLIED THERMAL ENGINEERING, 2005, 25 (10) :1419-1428
[46]   Selective water sorbent for solid sorption chiller: experimental results and modelling [J].
Restuccia, G ;
Freni, A ;
Vasta, S ;
Aristov, Y .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (03) :284-293
[47]   Performance evaluation of a low-temperature waste heat driven multi-bed adsorption chiller [J].
Saha, BB ;
Koyama, S ;
Lee, JB ;
Kuwahara, K ;
Alam, KCA ;
Hamamoto, Y ;
Akisawa, A ;
Kashiwagi, T .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2003, 29 (08) :1249-1263
[48]   Testing of a lab-scale four-bed adsorption heat pump [J].
San, Jung-Yang ;
Tsai, Fu-Kang .
APPLIED THERMAL ENGINEERING, 2014, 70 (01) :274-281
[49]   Water adsorption dynamics on representative pieces of real adsorbers for adsorptive chillers [J].
Santamaria, Salvatore ;
Sapienza, Alessio ;
Frazzica, Andrea ;
Freni, Angelo ;
Girnik, Ilya S. ;
Aristov, Yuri I. .
APPLIED ENERGY, 2014, 134 :11-19
[50]   Adsorption chilling driven by low temperature heat: New adsorbent and cycle optimization [J].
Sapienza, Alessio ;
Glaznev, Ivan S. ;
Santamaria, Salvatore ;
Freni, Angelo ;
Aristov, Yuriy I. .
APPLIED THERMAL ENGINEERING, 2012, 32 :141-146