Carbon coated gas electron multipliers

被引:13
作者
Beirle, S [1 ]
Werthenbach, U [1 ]
Zech, G [1 ]
Zeuner, T [1 ]
机构
[1] Univ Siegen, D-57068 Siegen, Germany
关键词
D O I
10.1016/S0168-9002(98)01315-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Gas electron multipliers (GEMs) have been overcoated with a high resistivity 10(14)-10(15) Omega/square amorphous carbon layer. The coating avoids charging up of the holes and provides a constant gain immediately after switching on independent of the rate. The gain uniformity across the GEM is improved. Coating opens the possibility to produce thick GEMs of very high gain. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
[41]   First results from cryogenic avalanche detectors based on gas electron multipliers [J].
Buzulutskov, A ;
Bondar, A ;
Shekhtman, L ;
Snopkov, R ;
Tikhonov, Y .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (06) :2491-2493
[42]   Basic properties of Gas Electron Multipliers for Cosmic X-Ray Polarimeters [J].
Iwahashi, T. ;
Tamagawa, T. ;
Hayato, A. ;
Nakamura, S. ;
Konami, S. ;
Asami, F. ;
Makishima, K. ;
Yasuda, N. ;
Kitamura, H. ;
Sakurai, H. ;
Tokanai, F. .
2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, :1234-+
[43]   Electron-electron interaction in carbon-coated ferromagnetic nanowires [J].
Brands, M ;
Carl, A ;
Posth, O ;
Dumpich, G .
PHYSICAL REVIEW B, 2005, 72 (08)
[44]   Electron holography of carbon-coated ferromagnetic nanoclusters [J].
Seraphin, S ;
Jiao, J ;
Beeli, C ;
Stadelmann, PA ;
Bonard, JM ;
Chatelain, A .
ELECTRON MICROSCOPY 1998, VOL 1: GENERAL INTEREST AND INSTRUMENTATION, 1998, :569-570
[45]   Subset gas condensate pipeline in coated carbon steel [J].
不详 .
MATERIALS PERFORMANCE, 2003, 42 (10) :42-43
[46]   Multichannel wire gas electron multipliers with 1- and 3-mm gaps [J].
B. M. Ovchinnikov ;
V. V. Parusov .
Instruments and Experimental Techniques, 2010, 53 :836-839
[47]   Construction and performance of a micro-pattern stereo detector with two gas electron multipliers [J].
Barvich, T ;
Blüm, P ;
Erdmann, M ;
Fahrer, M ;
Kärcher, K ;
Kühn, F ;
Mörmann, D ;
Müller, T ;
Neuberger, D ;
Röderer, F ;
Simonis, HJ ;
Skiba, A ;
Thümmel, WH ;
Weiler, T ;
Weseler, TWS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (03) :477-489
[48]   Multichannel Wire Gas Electron Multipliers with 1- and 3-mm Gaps [J].
Ovchinnikov, B. M. ;
Parusov, V. V. .
INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2010, 53 (06) :836-839
[49]   Two-phase argon and xenon avalanche detectors based on Gas Electron Multipliers [J].
Bondar, A ;
Buzulutskov, A ;
Grebenuk, A ;
Pavlyuchenko, D ;
Snopkov, R ;
Tikhonov, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 556 (01) :273-280
[50]   Development of a time projection chamber using gas electron multipliers (GEM-TPC) [J].
Oda, Susumu ;
Hamagaki, Hideki ;
Ozawa, Kyoichiro ;
Inuzuka, Masahide ;
Sakaguchi, Takao ;
Isobe, TadaAki ;
Gunji, Taku ;
Saito, Shota ;
Morino, Yuhei ;
Yamaguchi, Yorito ;
Sawada, Shin'ya ;
Yokkaichi, Satoshi .
2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, :940-944