Variability - Surface intensity distribution of large-area reference sources

被引:1
作者
da Silva Jr, Iremar Alves [1 ,2 ]
Siqueira, Paulo de T. D. [1 ]
do Nascimento, Eduardo [3 ]
Yoriyaz, Helio [1 ]
Sordi, Gian-Maria A. A. [1 ]
Potiens, Maria de Penha A. [1 ]
机构
[1] Inst Pesquisas Energet & Nucl, Ave Lineu Prestes,2242 Cidade Univ, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, BR-05508000 Sao Paulo, SP, Brazil
[3] Univ Fed Bahia, BR-40170115 Salvador, BA, Brazil
基金
巴西圣保罗研究基金会;
关键词
Variability; Large-area reference sources; Uniformity; Surface intensity distribution;
D O I
10.1016/j.apradiso.2020.109108
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this paper we present the impact of variability, a surface source parameter, on the efficiency evaluation of surface contamination monitors. This study was based on two source uniformity correction methodologies and data from real surface source distributions. Surface source intensity distribution has been changed by rearranging the cells (portions of the active area of each LARS) while keeping the same source uniformity value. Instrument efficiencies have been calculated for different sets of uniformities and variabilities. This study led to emphasize the importance of variability, a differential source intensity distribution parameter, over the uniformity, an integral source intensity distribution parameter, and reinforced the importance of the source uniformity correction procedure on the course of surface contamination monitor calibration.
引用
收藏
页数:7
相关论文
共 12 条
  • [1] [Anonymous], 2016, 8769 ISO
  • [2] [Anonymous], 2016, 75033 ISO
  • [3] [Anonymous], 2010, 8769 ISO
  • [4] Burgess P. H., 1983, Radiation Protection Dosimetry, V5, P125
  • [5] Lee C. J., 2014, GOOD PRACTICE GUIDE
  • [6] Characterization of photon-emitting wide area reference sources
    Naehle, O.
    Kossert, K.
    [J]. APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2018 - 2024
  • [7] Uniformity measurement of wide area reference sources for beta emitters
    Ohshiro, Masahiro
    Shiina, Takuya
    Yamada, Takahiro
    [J]. APPLIED RADIATION AND ISOTOPES, 2016, 109 : 397 - 401
  • [8] Silva Junior I.A., 2014, RADIO 2014 INT JOINT
  • [9] Silva Junior I.A., 2020, APPL RADIAT ISOTOPES, DOI DOI 10.1016/J.APRAISO.2020.109082
  • [10] Evaluation of the planar sources surface homogeneity used to instruments calibration
    Vivolo, Vitor
    Albuquerque Potiens, Maria da Penha
    [J]. APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 605 - 606