A new robust, deep eutectic-based floating organic droplets microextraction method for determination of lead in a portable syringe system directly couple with FAAS

被引:51
作者
Naeemullah [1 ,2 ]
Tuzen, Mustafa [1 ,3 ]
机构
[1] Tokat Gaziosmanpasa Univ, Fac Sci & Arts, Chem Dept, TR-60250 Tokat, Turkey
[2] Univ Turbat, Dept Chem, Balochistan 92600, Pakistan
[3] King Fahd Univ Petr & Minerals, Res Inst, Ctr Environm & Water, Dhahran 31261, Saudi Arabia
关键词
Lead; Deep eutectic; Microsampling; 2,9 dimethyl-4,7-diphenyl-1,10-phenanthroline; Flame atomic absorption spectrometry; Water and food samples; LIQUID-LIQUID MICROEXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; PHASE MICROEXTRACTION; WATER SAMPLES; TRACE DETERMINATION; SOLVENTS; EXTRACTION; PRECONCENTRATION; CADMIUM; SEPARATION;
D O I
10.1016/j.talanta.2018.12.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present method, a novel and simple portable in situ deep eutectic-based floating organic droplets dispersive liquid-liquid microextraction method was developed for lead in real food and water samples by a portable microsampling syringe system directly couple with FAAS (DES- SS). Choline chloride-decanoic acid (ChCl: Decanoic acid (1:1)) was used as a green hydrophobic deep eutectic-based floating organic droplets dispersive liquid-liquid microextraction of lead complex (Pb-2,9 dimethyl-4,7-diphenyl-1,10-phenanthroline) from real aqueous samples. The aqueous solution containing DES was rapidly 10 times sucked up/down by using a micro pipette tip syringe system to properly mix the extraction solvent in the aqueous medium. The whole solution was sucked into the micro pipette tip syringe system and placed in an ice bath for 5 min until decanoic base DES solidify into fine droplets. The solidify metal complex enriched (Pb-2,9 dimethy1-4,7-cliphenyl-1,10-phenanthroline) was fine droplets was separated by simply press manually the plunger syringe system inside to expel the lower aqueous to the beaker. The different variables were screened out statistically by using multivariate optimization. Under these optimal conditions, good responses were obtained in the concentration ranges of 2.5-100 g L-1. The relative standard deviation (RSD) and enhancement factor were found to be 4.2% and 150, respectively. The limit of detection (LOD) of the proposed method was found to be 0.086 mu g L-1. The t-test was used to check the validity of the proposed method while using CRM samples. It was observed that calculated t value 0.50 less than the t(crit) (2.91) at 95% confidence interval which indicating no significant difference between finding and certified values (p > 0.05). The relative % recovery is > 95%, indicated high validity and accuracy of the present method. The method was used to quantify the trace levels of lead in real water and food samples under optimized conditions.
引用
收藏
页码:71 / 77
页数:7
相关论文
共 39 条
[1]   Novel solvent properties of choline chloride/urea mixtures [J].
Abbott, AP ;
Capper, G ;
Davies, DL ;
Rasheed, RK ;
Tambyrajah, V .
CHEMICAL COMMUNICATIONS, 2003, (01) :70-71
[2]   Novel ion imprinted polymer magnetic mesoporous silica nano-particles for selective separation and determination of lead ions in food samples [J].
Aboufazeli, Forouzan ;
Zhad, Hamid Reza Lotfi Zadeh ;
Sadeghi, Omid ;
Karimi, Mohammad ;
Najafi, Ezzatollah .
FOOD CHEMISTRY, 2013, 141 (04) :3459-3465
[3]   Application of microwave-assisted dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry for ultra-trace determination of lead and cadmium in cereals and agricultural products [J].
Ataee, Mari ;
Ahmadi-Jouibari, Toraj ;
Fattahi, Nazir .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (03) :271-283
[4]   Temperature-controlled ionic liquid-liquid-phase microextraction for the pre-concentration of lead from environmental samples prior to flame atomic absorption spectrometry [J].
Bai, Huahua ;
Zhou, Qingxiang ;
Xie, Guohong ;
Xiao, Junping .
TALANTA, 2010, 80 (05) :1638-1642
[5]   Deep-eutectic solvents playing multiple roles in the synthesis of polymers and related materials [J].
Carriazo, Daniel ;
Concepcion Serrano, Maria ;
Concepcion Gutierrez, Maria ;
Luisa Ferrer, Maria ;
del Monte, Francisco .
CHEMICAL SOCIETY REVIEWS, 2012, 41 (14) :4996-5014
[6]   Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :215-222
[7]   A novel preconcentration procedure using cloud point extraction for determination of lead, cobalt and copper in water and food samples using flame atomic absorption spectrometry [J].
Citak, Demirhan ;
Tuzen, Mustafa .
FOOD AND CHEMICAL TOXICOLOGY, 2010, 48 (05) :1399-1404
[8]   Extraction techniques with deep eutectic solvents [J].
Cunha, Sara C. ;
Fernandes, Jose O. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 105 :225-239
[9]  
Dadfarnia S, 2002, B KOREAN CHEM SOC, V23, P545
[10]   Recent development in liquid phase microextraction for determination of trace level concentration of metals-A review [J].
Dadfarnia, Shayessteh ;
Shabani, Ali Mohammad Haji .
ANALYTICA CHIMICA ACTA, 2010, 658 (02) :107-119