Clinical gait evaluation of patients with knee osteoarthritis

被引:33
作者
Sun, Jun [1 ,2 ,3 ]
Liu, Yancheng [4 ]
Yan, Songhua [2 ,3 ]
Cao, Guanglei [5 ]
Wang, Shasha
Lester, D. Kevin
Zhang, Kuan [2 ,3 ]
机构
[1] Capital Med Univ, Beijing Youan Hosp, Dept Radiol, Beijing, Peoples R China
[2] Capital Med Univ, Sch Biomed Engn, 10 Xitoutiao, Beijing 100069, Peoples R China
[3] Capital Med Univ, Beijing Key Lab Fundamental Res Biomech Clin Appl, Beijing, Peoples R China
[4] Tianjin Hosp, Dept Spinal Surg, Tianjin, Peoples R China
[5] Capital Med Univ, Xuanwu Hosp, Beijing, Peoples R China
基金
高等学校博士学科点专项科研基金;
关键词
Knee osteoarthritis; Gait; Portable Gait Analyzer; IDEEA; GoPro Hero; RELIABILITY; QUANTIFICATION; PARAMETERS; SYSTEM; IDEEA; SEVERITY; VALIDITY; WALKING; HIP;
D O I
10.1016/j.gaitpost.2017.08.009
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Knee osteoarthritis (KOA) is the most common osteoarthritis in lower limbs, and gait measurement is important to evaluate walking function of KOA patients before and after treatment. The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3) is a portable gait analysis system to evaluate gaits. This study is to evaluate the accuracy and reliability of IDEEA3 for gait measurement of KOA patients. Meanwhile, gait differences between KOA patients and healthy subjects are examined. Twelve healthy volunteers were recruited for measurement comparison of gait cycle (GC), cadence, step length, velocity and step counts between a motion analysis system and a high-speed camera (GoPro Hero3). Twenty-three KOA patients were recruited for measurement comparison of former five parameters between GoPro Hero3 and IDEEA3. Paired t-test, Concordance Correlation Coefficient (CCC) and Intraclass Correlation Coefficient (ICC) were used for data analysis. All p-values of paired t- tests for GC, cadence, step length and velocity were greater than 0.05 while all CCC and ICC results were above 0.95. The measurements of GC, cadence, step length, velocity and step counts by motion analysis system are highly consistent with the measurements by GoPro Hero3. The measurements of former parameters by GoPro Hero3 are not statistically different from the measurements by IDEEA3. IDEEA3 can be effectively used for the measurement of GC, cadence, step length, velocity and step counts in KOA patients. The KOA patients walk with longer GC, lower cadence, shorter step length and slower speed compared with healthy subjects in natural speed with flat shoes.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 28 条
[1]   Gait and neuromuscular pattern changes are associated with differences in knee osteoarthritis severity levels [J].
Astephen, Janie L. ;
Deluzio, Kevin J. ;
Caldwell, Graham E. ;
Dunbar, Michael J. ;
Hubley-Kozey, Cheryl L. .
JOURNAL OF BIOMECHANICS, 2008, 41 (04) :868-876
[2]   Concurrent validation of activity monitors in patients with rheumatoid arthritis [J].
Backhouse, Michael R. ;
Hensor, Elizabeth M. A. ;
White, Derrick ;
Keenan, Anne-Maree ;
Helliwell, Philip S. ;
Redmond, Anthony C. .
CLINICAL BIOMECHANICS, 2013, 28 (04) :473-479
[3]   Comfortable and maximum walking speed of adults aged 20-79 years: Reference values and determinants [J].
Bohannon, RW .
AGE AND AGEING, 1997, 26 (01) :15-19
[4]   Risk factors for incident osteoarthritis of the hip and knee [J].
Chaganti R.K. ;
Lane N.E. .
Current Reviews in Musculoskeletal Medicine, 2011, 4 (3) :99-104
[5]   Comparison of ICC and CCC for assessing agreement for data without and with replications [J].
Chen, Chia-Cheng ;
Barnhart, Huiman X. .
COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2008, 53 (02) :554-564
[6]   APOS therapy improves clinical measurements and gait in patients with knee osteoarthritis [J].
Elbaz, Avi ;
Mor, Amit ;
Segal, Ganit ;
Debbi, Eytan ;
Haim, Amir ;
Halperin, Nahum ;
Debi, Ronen .
CLINICAL BIOMECHANICS, 2010, 25 (09) :920-925
[7]   Real-time gait event detection for normal subjects from lower trunk accelerations [J].
Gonzalez, Rafael C. ;
Lopez, Antonio M. ;
Rodriguez-Uria, Javier ;
Alvarez, Diego ;
Alvarez, Juan C. .
GAIT & POSTURE, 2010, 31 (03) :322-325
[8]   Test-retest reliability of the IDEEA system in the quantification of step parameters during walking and stair climbing [J].
Gorelick, Mark L. ;
Bizzini, Mario ;
Maffiuletti, Nicola A. ;
Munzinger, Jeannette Petrich ;
Munzinger, Urs .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2009, 29 (04) :271-276
[9]   Real-time gait event detection using wearable sensors [J].
Hanlon, Michael ;
Anderson, Ross .
GAIT & POSTURE, 2009, 30 (04) :523-527
[10]  
Hu J., 2015, JIANGSU MED J, V41, P1640