Intermodel disagreement of myocardial blood flow estimation from dynamic CT perfusion imaging

被引:16
作者
van Assen, Manly [1 ,2 ]
Pelgrim, Gert Jan [2 ]
de Cecco, Carlo N. [1 ,4 ]
Stijnen, J. Marco A. [3 ]
Zaki, Beatrice M. [1 ]
Oudkerk, Matthijs [2 ]
Vliegenthart, Rozemarijn [1 ,2 ]
Schoepf, U. Joseph [1 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, 25 Courtenay Dr, Charleston, SC 29425 USA
[2] Univ Groningen, Ctr Med Imaging, Univ Med Ctr Groningen, Groningen, Netherlands
[3] LifeTec Grp, Eindhoven, Netherlands
[4] Emory Univ Hosp, Div Cardiothorac Imaging Nucl Med & Mol Imaging, Dept Radiol & Imaging Sci, 1364 Clifton Rd NE, Atlanta, GA 30322 USA
关键词
Computed tomography; Perfusion imaging; Myocardium; Tracer kinetic models; GLOBAL QUANTIFICATION; ACCURACY; ABSOLUTE;
D O I
10.1016/j.ejrad.2018.11.029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the intermodel agreement of different tracer kinetic models to determine myocardial blood flow (MBF) and their diagnostic accuracy in coronary artery disease (CAD) at dynamic CT myocardial perfusion imaging (CTMPI). Methods: Three porcine hearts perfused in Langendorff mode and 15 patients with suspected CAD and perfusion single photon emission CT (SPECT) were included. Dynamic CTMPI was performed in shuffle-mode (70 kVp, 350mAs/rot) on 3rd generation dual-source CT. In porcine hearts and patients, myocardial segments (AHA-16-segment model) were drawn. Tissue attenuation curves were constructed per segment and arterial input functions were derived from the aorta. True MBF was calculated with input flow and weight of the porcine hearts. In patients, ischemic segments were based on SPECT results. MBF quantification was performed using the VPCT-software, Upslope, Extended Toft (ET), Two-compartment (TC) and Fermi models. Results: In porcine hearts, true MBF was 1.88 (interquartile range [IQR]:1.80-2.80)mL/g/min. Diagnostic accuracy was similar for all models: 0.96, 0.99, 0.92, 0.93 and 0.96 for VPCT software, Upslope method, Fermi, ET and TC model. The VPCT software and Upslope method resulted in lower MBF (median 1.44 [1.29-1.58] and 1.39 [1.25-1.59]mL/g/min) compared to the Fermi, ET, and TC model (median values of 1.76 mL/g/min [1.36-2.44], 2.55 mL/g/min [2.20-2.92], and 1.98 mL/g/min [1.60-2.60], respectively [p < 0.001]). In patients, all models showed a significant difference in MBF between the 34 ischemic and 206 non-ischemic segments (p-value < 0.001). Conclusion: Absolute MBF values are significantly different between the models and a uniform threshold could not be determined; however, diagnostic accuracy for detecting ischemia is similar.
引用
收藏
页码:175 / 180
页数:6
相关论文
共 32 条
[1]  
[Anonymous], EUR RADIOL
[2]   Accuracy of Dynamic Computed Tomography Adenosine Stress Myocardial Perfusion Imaging in Estimating Myocardial Blood Flow at Various Degrees of Coronary Artery Stenosis Using a Porcine Animal Model [J].
Bamberg, Fabian ;
Hinkel, Rabea ;
Schwarz, Florian ;
Sandner, Torleif A. ;
Baloch, Elisabeth ;
Marcus, Roy ;
Becker, Alexander ;
Kupatt, Christian ;
Wintersperger, Bernd J. ;
Johnson, Thorsten R. ;
Theisen, Daniel ;
Klotz, Ernst ;
Reiser, Maximilian F. ;
Nikolaou, Konstantin .
INVESTIGATIVE RADIOLOGY, 2012, 47 (01) :71-77
[3]   Adenosine-Stress Dynamic Myocardial CT Perfusion Imaging Initial Clinical Experience [J].
Bastarrika, Gorka ;
Ramos-Duran, Luis ;
Rosenblum, Michael A. ;
Kang, Doo Kyoung ;
Rowe, Garrett W. ;
Schoepf, U. Joseph .
INVESTIGATIVE RADIOLOGY, 2010, 45 (06) :306-313
[4]   Comparison of the Diagnostic Performance of Four Quantitative Myocardial Perfusion Estimation Methods Used in Cardiac MR Imaging: CE-MARC Substudy [J].
Biglands, John D. ;
Magee, Derek R. ;
Sourbron, Steven P. ;
Plein, Sven ;
Greenwood, John P. ;
Radjenovic, Aleksandra .
RADIOLOGY, 2015, 275 (02) :393-402
[5]   Comparison of blood flow models and acquisitions for quantitative myocardial perfusion estimation from dynamic CT [J].
Bindschadler, Michael ;
Modgil, Dimple ;
Branch, Kelley R. ;
La Riviere, Patrick J. ;
Alessio, Adam M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (07) :1533-1556
[6]   DIRECT COMPARISON OF [N-13] AMMONIA AND [O-15]WATER ESTIMATES OF PERFUSION WITH QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW BY MICROSPHERES [J].
BOL, A ;
MELIN, JA ;
VANOVERSCHELDE, JL ;
BAUDHUIN, T ;
VOGELAERS, D ;
DEPAUW, M ;
MICHEL, C ;
LUXEN, A ;
LABAR, D ;
COGNEAU, M ;
ROBERT, A ;
HEYNDRICKX, GR ;
WIJNS, W .
CIRCULATION, 1993, 87 (02) :512-525
[7]   Dynamic CT myocardial perfusion imaging [J].
Caruso, Damiano ;
Eid, Marwen ;
Schoepf, U. Joseph ;
Jin, Kwang Nam ;
Varga-Szemes, Akos ;
Tesche, Christian ;
Mangold, Stefanie ;
Spandorfer, Adam ;
Laghi, Andrea ;
De Cecco, Carlo N. .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) :1893-1899
[8]   Static and dynamic assessment of myocardial perfusion by computed tomography [J].
Danad, Ibrahim ;
Szymonifka, Jackie ;
Schulman-Marcus, Joshua ;
Min, James K. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (08) :836-844
[9]   Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PET [J].
El Fakhri, Georges ;
Kardan, Arash ;
Sitek, Arkadiusz ;
Dorbala, Sharmila ;
Abi-Hatem, Nathalie ;
Lahoud, Youmna ;
Fischman, Alan ;
Coughlan, Martha ;
Yasuda, Tsunehiro ;
Di Carli, Marcelo F. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (07) :1062-1071
[10]   Quantification of myocardial perfusion using dynamic 64-detector computed tomography [J].
George, Richard T. ;
Jerosch-Herold, Michael ;
Silva, Caterina ;
Kitagawa, Kakuya ;
Bluenike, David A. ;
Linia, Joao A. C. ;
Lardo, Albert C. .
INVESTIGATIVE RADIOLOGY, 2007, 42 (12) :815-822