Surface modification of polypropylene membranes by γ-ray induced graft copolymerization and their solute permeation characteristics

被引:166
作者
Shim, JK
Na, HS
Lee, YM [1 ]
Huh, H
Nho, YC
机构
[1] Hanyang Univ, Coll Engn, Sch Chem Engn, Seoul 133791, South Korea
[2] Korea Inst Ind Technol, Cleaner Prod Technol R&D Ctr, Choan 330825, South Korea
[3] Korea Atom Energy Res Inst, Radioisotopes Radiat Applicat Team, Taejon 305606, South Korea
关键词
gamma-ray irradiation; membrane; surface modification; hydrophilicity; BSA;
D O I
10.1016/S0376-7388(01)00445-8
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Porous hydrophobic polypropylene (PP) membranes were subjected to the surface modification by the gamma -ray induced graft copolymerization with hydrophilic 2-hydroxyethyl methacrylate (HEMA). The structural changes and surface morphologies of the modified PP membranes were characterized by a Fourier transform infrared spectroscopy (FT-IR), elemental analysis (EA) and field emission scanning electron microscopy (FE-SEM). Peroxides produced from gamma -ray irradiation were determined by a 1,1-diphenyl-2-picryl hydrazyl (DPPH) method and the surface hydrophilicities of membranes were measured by a static contact angle measurement. The contact angle of the modified membranes reduced with the degree of grafting (DG) of HEMA onto the membrane surface., and it decreased up to about half of that before modification. The permeation behaviors of all membranes were investigated by a bovine serum albumin (BSA) filtration experiment. As a result, the DG of the modified membrane increased with the reaction time. However. in the case of irradiation dosage it showed the maximum value at 20 kGy. Also, the modified membrane showed a higher solution flux, lower BSA adsorption, and the better flux recovery after cleaning than that of the unmodified membrane. Particularly, 40.6% grafted membrane showed a two-fold increase in a BSA solution flux, 62% reduction in total fouling and three-fold increase in flux recovery after chemical cleaning. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 226
页数:12
相关论文
共 34 条
[1]   SURFACE MODIFICATION OF POLYMERS .1. VAPOR-PHASE PHOTOGRAFTING WITH ACRYLIC-ACID [J].
ALLMER, K ;
HULT, A ;
RANBY, B .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1988, 26 (08) :2099-2111
[2]  
Andrade J.D., 1985, SURFACE INTERFACIAL, V1, P249, DOI [10.1007/978-1-4684-8610-0_7, DOI 10.1007/978-1-4684-8610-0_7]
[3]  
BURLANT WJ, 1958, BLOCK GRAFT POLYM
[4]  
Chen H, 1999, J APPL POLYM SCI, V72, P1699, DOI 10.1002/(SICI)1097-4628(19990624)72:13<1699::AID-APP6>3.0.CO
[5]  
2-9
[6]   ESCA APPLIED TO POLYMERS .15. RF GLOW-DISCHARGE MODIFICATION OF POLYMERS, STUDIED BY MEANS OF ESCA IN TERMS OF A DIRECT AND RADIATIVE ENERGY-TRANSFER MODEL [J].
CLARK, DT ;
DILKS, A .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1977, 15 (10) :2321-2345
[7]  
Dessouki AM, 1998, POLYM INT, V45, P67, DOI 10.1002/(SICI)1097-0126(199801)45:1<67::AID-PI896>3.0.CO
[8]  
2-A
[9]  
Garg DH, 1996, J APPL POLYM SCI, V60, P2087
[10]   CONTACT ANGLES OF ULTRAFILTRATION MEMBRANES AND THEIR POSSIBLE CORRELATION TO MEMBRANE PERFORMANCE [J].
GEKAS, V ;
PERSSON, KM ;
WAHLGREN, M ;
SIVIK, B .
JOURNAL OF MEMBRANE SCIENCE, 1992, 72 (03) :293-302