Characterization of Valley Winter Woodsmoke Concentrations in Northern NY Using Highly Time-Resolved Measurements

被引:24
作者
Allen, George A.
Miller, Paul J.
Rector, Lisa J.
Brauer, Michael [1 ]
Su, Jason G. [2 ]
机构
[1] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[2] Univ Calif Berkeley, Berkeley, CA 94720 USA
关键词
Aethalometer; Nephelometer; Spatial variability; Mobile measurements; Outdoor wood boilers; Woodsmoke; EXPERIMENTAL EXPOSURE; WOOD-SMOKE; LIGHT-ABSORPTION; AIR-POLLUTION; INFLAMMATION; GENERATION; PARTICLES; CARBON;
D O I
10.4209/aaqr.2011.03.0031
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The increasing popularity of wood fired heating appliances in cold winter climates has focused attention on assessment of woodsmoke exposures. Pollution from residential wood combustion (RWC) is a major concern in areas with valley topography where nighttime inversions limit the dispersion of pollutants from ground-level sources. An intensive characterization of ambient particulate mater (PM) from RWC was performed in northern New York State during winter 2008-2009 in an area where the 2005 U.S. EPA National Emissions Inventory shows RWC to be the largest source of PM2.5. Measurements of woodsmoke PM were made using optical scattering and absorption techniques during repeated night-time mobile monitoring to provide data with high spatial and temporal resolution; measurements were also made at six fixed sites for the study period to provide temporal context for the mobile measurements. The difference in optical absorption at near-infrared and near-ultraviolet wavelengths was used as a specific marker for woodsmoke PM. Woodsmoke was the only significant contributor to elevated night-time valley PM concentrations during mobile run nights; short-term (3 minute) PM concentrations frequently exceeded 100 mu g/m(3). Concentrations observed with mobile monitoring were consistently elevated at valley bottoms where the majority of the population lives, and approached zero outside of valleys. Data from fixed sites indicated that woodsmoke levels peaked near midnight, with a secondary peak around 7 AM and a mid-day minimum. These patterns are consistent with RWC use and diurnal patterns of atmospheric dispersion.
引用
收藏
页码:519 / 530
页数:12
相关论文
共 30 条
  • [11] A spatial model of urban winter woodsmoke concentrations
    Larson, Timothy
    Su, Jason
    Baribeau, Anne-Marie
    Buzzelli, Michael
    Setton, Eleanor
    Brauer, Michael
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (07) : 2429 - 2436
  • [12] Generation and characterization of hardwood smoke inhalation exposure atmospheres
    McDonald, Jacob D.
    White, Richard K.
    Barr, Edward B.
    Zielinska, Barbara
    Chow, Judith C.
    Grosjean, Eric
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2006, 40 (08) : 573 - 584
  • [13] Fine particle and gaseous emission rates from residential wood combustion
    McDonald, JD
    Zielinska, B
    Fujita, EM
    Sagebiel, JC
    Chow, JC
    Watson, JG
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (11) : 2080 - 2091
  • [14] Molenar J.V., 2000, P PM2000 PART MATT H
  • [15] Woodsmoke health effects: A review
    Naeher, Luke P.
    Brauer, Michael
    Lipsett, Michael
    Zelikoff, Judith T.
    Simpson, Christopher D.
    Koenig, Jane Q.
    Smith, Kirk R.
    [J]. INHALATION TOXICOLOGY, 2007, 19 (01) : 67 - 106
  • [16] *NYSERDA, 2008, 0801 NYSERDA
  • [17] NYSERDA (New York State Energy and Research Development Authority), 2006, 0602 NYSERDA
  • [18] NYSERDA (New York State Energy and Research Development Authority), 2010, 1002 NYSERDA
  • [19] Intake Fraction of Urban Wood Smoke
    Ries, Francis J.
    Marshall, Julian D.
    Brauer, Michael
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (13) : 4701 - 4706
  • [20] Russell N., 2011, EM MAGAZINE, P19