Motion estimation and correction for simultaneous PET/MR using SIRF and CIL

被引:8
作者
Brown, Richard [1 ,2 ]
Kolbitsch, Christoph [2 ,3 ]
Delplancke, Claire [4 ]
Papoutsellis, Evangelos [5 ,6 ]
Mayer, Johannes [3 ]
Ovtchinnikov, Evgueni [5 ]
Pasca, Edoardo [5 ]
Neji, Radhouene [2 ,7 ]
Costa-luis, Casper da [2 ]
Gillman, Ashley G. [8 ]
Ehrhardt, Matthias J. [4 ,9 ]
McClelland, Jamie R. [10 ,11 ]
Eiben, Bjoern [10 ,11 ]
Thielemans, Kris [1 ,11 ]
机构
[1] UCL, Inst Nucl Med, London, England
[2] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[3] Phys Tech Bundesanstalt, Braunschweig, Germany
[4] Univ Bath, Dept Math Sci, Bath, Avon, England
[5] Rutherford Appleton Lab, STFC, Sci Comp Dept, UKRI, Harwell Campus, Didcot, Oxon, England
[6] Univ Manchester, Henry Royce Inst, Dept Mat, Manchester, Lancs, England
[7] Siemens Healthcare, MR Res Collaborat, Frimley, England
[8] CSIRO, Australian E Hlth Res Ctr, Townsville, Qld, Australia
[9] Univ Bath, Inst Math Innovat, Bath, Avon, England
[10] UCL, Ctr Med Image Comp, London, England
[11] UCL, Dept Med Phys & Biomed Engn, London, England
来源
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES | 2021年 / 379卷 / 2204期
基金
英国工程与自然科学研究理事会;
关键词
Motion; correction; estimation; PET; MR; SIRF; RESPIRATORY MOTION; IMAGE-RECONSTRUCTION; GENERALIZED RECONSTRUCTION; JOINT ESTIMATION; MRI; MODELS; COMPENSATION; INVERSION; FRAMEWORK; SOFTWARE;
D O I
10.1098/rsta.2020.0208
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
SIRF is a powerful PET/MR image reconstruction research tool for processing data and developing new algorithms. In this research, new developments to SIRF are presented, with focus on motion estimation and correction. SIRF's recent inclusion of the adjoint of the resampling operator allows gradient propagation through resampling, enabling the MCIR technique. Another enhancement enabled registering and resampling of complex images, suitable for MRI. Furthermore, SIRF's integration with the optimization library CIL enables the use of novel algorithms. Finally, SPM is now supported, in addition to NiftyReg, for registration. Results of MR and PET MCIR reconstructions are presented, using FISTA and PDHG, respectively. These demonstrate the advantages of incorporating motion correction and variational and structural priors. This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 2'.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Demonstration of motion correction for PET-MR with PVA cryogel phantoms
    Soultanidis, Georgios M.
    Polycarpou, Irene
    Weissler, Bjorn
    Lerche, Christoph
    Mackewn, Jane E.
    Ayres, Richard
    Tsoumpas, Charalampos
    Schulz, Volkmar
    Marsden, Paul K.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [22] Monte Carlo simulation of PET/MR scanner and assessment of motion correction strategies
    Isin, A.
    Ozsahin, D. Uzun
    Dutta, J.
    Haddani, S.
    El-Fakhri, G.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [23] Pulmonary imaging using respiratory motion compensated simultaneous PET/MR
    Dutta, Joyita
    Huang, Chuan
    Li, Quanzheng
    El Fakhri, Georges
    MEDICAL PHYSICS, 2015, 42 (07) : 4227 - 4240
  • [24] Evaluating different methods of MR-based motion correction in simultaneous PET/MR using a head phantom moved by a robotic system
    Einspanner, Eric
    Jochimsen, Thies H.
    Harries, Johanna
    Melzer, Andreas
    Unger, Michael
    Brown, Richard
    Thielemans, Kris
    Sabri, Osama
    Sattler, Bernhard
    EJNMMI PHYSICS, 2022, 9 (01)
  • [25] Evaluating different methods of MR-based motion correction in simultaneous PET/MR using a head phantom moved by a robotic system
    Eric Einspänner
    Thies H. Jochimsen
    Johanna Harries
    Andreas Melzer
    Michael Unger
    Richard Brown
    Kris Thielemans
    Osama Sabri
    Bernhard Sattler
    EJNMMI Physics, 9
  • [26] Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies
    Huang, Chuan
    Petibon, Yoann
    Ouyang, Jinsong
    Reese, Timothy G.
    Ahlman, Mark A.
    Bluemke, David A.
    El Fakhri, Georges
    MEDICAL PHYSICS, 2015, 42 (02) : 1087 - 1097
  • [27] Registration-weighted motion correction for PET
    Dikaios, Nikolaos
    Fryer, Tim D.
    MEDICAL PHYSICS, 2012, 39 (03) : 1253 - 1264
  • [28] PET respiratory motion correction: quo vadis?
    Lamare, F.
    Bousse, A.
    Thielemans, K.
    Liu, C.
    Merlin, T.
    Fayad, H.
    Visvikis, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (03)
  • [29] Respiratory motion compensation for simultaneous PET/MR based on highly undersampled MR data
    Rank, Christopher M.
    Heusser, Thorsten
    Wetscherek, Andreas
    Freitag, Martin T.
    Sedlaczek, Oliver
    Schlemmer, Heinz-Peter
    Kachelriess, Marc
    MEDICAL PHYSICS, 2016, 43 (12) : 6234 - 6245
  • [30] Scatter estimation and motion correction in PET
    Thielemans, Kris
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1745 - 1747