Hormone Immunoassay Interference: A 2021 Update

被引:56
作者
Ghazal, Khaldoun [1 ]
Brabant, Severine [1 ]
Prie, Dominique [1 ]
Piketty, Marie-Liesse [1 ]
机构
[1] Paris Ctr Univ, Necker Enfants Malad Hosp, AP HP, Dept Funct Explorat, 149 Rue Sevres, F-75743 Paris 15, France
关键词
Immunoassay; Hormone; Interference; Heterophile antibodies; Biotin; HIGH-DOSE BIOTIN; FAMILIAL DYSALBUMINEMIC HYPERTHYROXINEMIA; HETEROPHILIC ANTIBODY INTERFERENCE; POLYETHYLENE-GLYCOL PRECIPITATION; DIFFERENTIATED THYROID-CANCER; EXTERNAL QUALITY ASSESSMENT; MACRO-THYROTROPIN; CROSS-REACTIVITY; AUTOANTIBODY INTERFERENCE; STREPTAVIDIN ANTIBODIES;
D O I
10.3343/alm.2022.42.1.3
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Immunoassays are powerful qualitative and quantitative analytical techniques. Since the first description of an immunoassay method in 1959, advances have been made in assay designs and analytical characteristics, opening the door for their widespread implementation in clinical laboratories. Clinical endocrinology is closely linked to laboratory medicine because hormone quantification is important for the diagnosis, treatment, and prognosis of endocrine disorders. Several interferences in immunoassays have been identified through the years; although some are no longer encountered in daily practice, cross-reaction, heterophile antibodies, biotin, and anti-analyte antibodies still cause problems. Newer interferences are also emerging with the development of new therapies. The interfering substance may be exogenous (e.g., a drug or substance absorbed by the patient) or endogenous (e.g., antibodies produced by the patient), and the bias caused by interference can be positive or negative. The consequences of interference can be deleterious when clinicians consider erroneous results to establish a diagnosis, leading to unnecessary explorations or inappropriate treatments. Clinical laboratories and manufacturers continue to investigate methods for the detection, elimination, and prevention of interferences. However, no system is completely devoid of such incidents. In this review, we focus on the analytical interferences encountered in daily practice and possible solutions for their detection or elimination.
引用
收藏
页码:3 / 23
页数:21
相关论文
共 196 条
[1]   Hypeprolactinemia: still an insidious diagnosis [J].
Aliberti, Ludovica ;
Gagliardi, Irene ;
Dorizzi, Romolo M. ;
Pizzicotti, Stefano ;
Bondanelli, Marta ;
Zatelli, Maria Chiara ;
Ambrosio, Maria Rosaria .
ENDOCRINE, 2021, 72 (03) :928-931
[2]   Letter to the Editor: Assay-specific Spurious ACTH Results Lead to Misdiagnosis, Unnecessary Testing, and Surgical Misadventure-A Case Series [J].
Altawallbeh, Ghaith ;
Karger, Amy B. .
JOURNAL OF THE ENDOCRINE SOCIETY, 2020, 4 (02)
[3]   Non-specific activities against ruthenium crosslinker as a new cause of assay interference in an electrochemilluminescent immunoassay [J].
Ando, Takao ;
Yasui, Jun-ichi ;
Inokuchi, Naoko ;
Usa, Toshiro ;
Ashizawa, Kiyohito ;
Kamihara, Shimeru ;
Eguchi, Katsumi .
INTERNAL MEDICINE, 2007, 46 (15) :1225-1229
[4]   False positive in the measurement of thyroglobulin induced by rheumatoid factor [J].
Astarita, G. ;
Gutierrez, S. ;
Kogovsek, N. ;
Mormandi, E. ;
Otero, P. ;
Calabrese, C. ;
Alcaraz, G. ;
Vazquez, A. ;
Abalovich, M. .
CLINICA CHIMICA ACTA, 2015, 447 :43-46
[5]   Biotin interference in immunoassay: a review for the laboratory scientist [J].
Avery, Gordon .
ANNALS OF CLINICAL BIOCHEMISTRY, 2019, 56 (04) :424-430
[6]   Misdiagnosis of Graves' Disease with Apparent Severe Hyperthyroidism in a Patient Taking Biotin Megadoses [J].
Barbesino, Giuseppe .
THYROID, 2016, 26 (06) :860-863
[7]   Observational studies on macroprolactin in a routine clinical laboratory [J].
Barth, Julian H. ;
Lippiatt, Carys M. ;
Gibbons, Stephen G. ;
Desborough, Robert A. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (08) :1259-1262
[8]   Erroneous thyroid and steroid hormones profile due to anti-streptavidin antibodies [J].
Bayart, Jean-Louis ;
Favresse, Julien ;
Melnik, Ekaterina ;
Lardinois, Benjamin ;
Fillee, Catherine ;
Maiter, Dominique ;
Gruson, Damien .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2019, 57 (10) :E255-E258
[9]  
Beato-Víbora PI, 2017, INT J ENDOCRINOL MET, V15, DOI 10.5812/ijem.37792
[10]   Measured Dehydroepiandrosterone Sulfate Positively Influences Testosterone Measurement in Unextracted Female Serum: Comparison of 2 Immunoassays with Testosterone Measured by LC-MS [J].
Benton, Sally C. ;
Nuttall, Michelle ;
Nardo, Luciano ;
Laing, Ian .
CLINICAL CHEMISTRY, 2011, 57 (07) :1074-1075