Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures

被引:1
|
作者
Usta, Emirhan [1 ]
Akpolat, Ahmet O. [2 ]
Kahraman, Ahmet N. [3 ]
Kara, Adnan [4 ]
Oc, Yunus [5 ]
Kilinc, Bekir E. [6 ]
机构
[1] Urfa Traning & Res Hosp, Dept Orthopaed & Traumatol, Sanliurfa, Turkey
[2] Hlth Sci Univ, Istanbul Fatih Sultan Mehmet Training & Res Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[3] Hlth Sci Univ, Istanbul Fatih Sultan Mehmet Training & Res Hosp, Dept Radiol, Istanbul, Turkey
[4] Medipol Hosp, Orthopaed & Traumatol, Istanbul, Turkey
[5] Beykent Univ, Dept Orthopaed & Traumatol, Sch Med, Istanbul, Turkey
[6] Univ Hlth Sci, Fatih Sultan Mehmet Training & Res Hosp, Orthopaed Surg & Traumatolagy, Istanbul, Turkey
关键词
coronal malposition; tenosynovitis; flexor pollicis longus; volar locking plate; distal radius fracture; COMPLICATIONS; FIXATION;
D O I
10.7759/cureus.26444
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: Literature does not show any studies regarding plate placement problems in the coronal plane of patients with volar plating due to distal radius fracture diagnosis. We aimed to investigate the functional and laboratory results of the coronal malposition of the volar locking plate in patients with distal radius fracture treated with internal fixation. Methods: In this retrospective study, we included patients who had volar plate fixation, were aged between 18 and 80, had no pathological fracture, had a minimum of six months of follow-up, and had the same rehabilitation protocol. We consider the angle subtended on the coronal axis between the distal radius long axis and the distal radius locking plate as coronal malposition. We named the coronal malposition angle the "AYE Angle." Patients with an AYE angle of over 1 degree were evaluated under group 1. Patients with an AYE angle of 0-1 degrees were evaluated under group 2. Radiological parameters were taken from AP-Lateral X-ray views. Superficial University System of Georgia (USG) examinations were applied to detect tendon problems. The DASH and QUICK-DASH scoring systems were used for clinical evaluation. Grip strength was measured with a dynamometer in all patients. All results were compared between the two groups. Results: Thirteen patients were female and 27 patients were male. Nineteen patients who had coronal malposition were added to group 1, while 21 patients who had no coronal malposition were added to group 2. Fifteen patients had normal USG results in group 2, while 18 patients had edema around the flexor pollicis longus (FPL) tendon as a result of USG in group 1. Statistically, a significant difference was detected between the two groups in terms of the amount of tenosynovitis around FPL (p=0.01). A statistically significant relationship was found between USG grading and malposition grading. The study revealed that a higher rate of USG grade 2 was found in patients with malposition grade 2 (90.9%), while a higher rate of USG grade 1 (50%) was observed in patients with malposition grade 1 (p=0.01). A statistically significant difference was not found between Soong grading and USG in terms of the level of tenosynovitis around the FPL tendon. The amount of tenosynovitis detected around the FPL tendon was 62.5% for Soong and grade 0 level, 60.7% for grade 1 level, and 50% for grade 2 level. There was no statistically significant difference between the two groups in the DASH and QUICK-DASH scoring systems (p=0.96). There was no statistically significant difference between the two groups in the grip strength (p=0.52). Conclusion: Coronal plate position in the treatment of the distal radius fracture is important to avoid potential flexor tendon problems. The volar plate position should be adjusted properly both in the coronal and sagittal axes.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Comparison of Intramedullary Nail and Volar Locking Plate for Distal Radius Fractures: A Systematic Review and Meta-Analysis of Randomised Controlled Trials
    Chen, Zehong
    Zhu, Yinan
    Zhang, Wei
    Eltagy, Hassan
    Elerian, Sherif
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [42] Incidence of complications and secondary procedure following distal radius fractures treated by volar locking plate (VLP)
    Yansen Li
    Yanqing Zhou
    Xiong Zhang
    Dehu Tian
    Bing Zhang
    Journal of Orthopaedic Surgery and Research, 14
  • [43] Complications After Volar Locking Plate Fixation of Distal Radius Fractures: A Retrospective Study of 822 Patients
    Perregaard, Soren
    Jorgensen, Rasmus Wejnold
    Landgren, Marcus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (08): : 745 - 750
  • [44] Biomechanical Properties of 3-Dimensional Printed Volar Locking Distal Radius Plate: Comparison With Conventional Volar Locking Plate
    Kim, Sung-Jae
    Jo, Young-Hoon
    Choi, Wan-Sun
    Lee, Chang-Hun
    Lee, Bong-Gun
    Kim, Joo-Hak
    Lee, Kwang-Hyun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (09): : 747.e1 - 747.e6
  • [45] Computed Tomography and Pathobiomechanical-Based Treatment of Volar Distal Radius Fractures
    Hintringer, Wolfgang
    Rosenauer, Rudolf
    Quadlbauer, Stefan
    JOURNAL OF WRIST SURGERY, 2022, 11 (03) : 203 - 213
  • [46] Pearls and Pitfalls of the Volar Locking Plating for Distal Radius Fractures
    Im, Jin-Hyung
    Lee, Joo-Yup
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (02) : 125 - 132
  • [47] Treatment of AO type C distal radius fractures with the use of volar locked plate
    Seyfettinoglu, Firat
    Ogur, Hasan Ulas
    Tuhanioglu, Umit
    Ciloglu, Osman
    Cicek, Hakan
    CUKUROVA MEDICAL JOURNAL, 2018, 43 (01): : 49 - 55
  • [48] Can the Use of Variable-Angle Volar Locking Plates Compensate for Suboptimal Plate Positioning in Unstable Distal Radius Fractures? A Biomechanical Study
    Hart, Adam
    Collins, Melissa
    Chhatwal, Dane
    Steffen, Thomas
    Harvey, Edward J.
    Martineau, Paul A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (01) : E1 - E6
  • [49] Risk Assessment of Tendon Attrition Following Treatment of Distal Radius Fractures With Volar Locking Plates Using Audible Crepitus and Placement of the Plate: A Prospective Clinical Cohort Study
    Yamazaki, Hiroshi
    Uchiyama, Shigeharu
    Komatsu, Masatoshi
    Hashimoto, Shun
    Kato, Hiroyuki
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (08): : 1571 - 1581
  • [50] Optimal screw length in volar locking plate osteosynthesis for distal radius fractures: a systematic review
    Gunaratne, Rajitha
    Nazifi, Omid
    D'Souza, Harry
    Tay, Aaron
    ANZ JOURNAL OF SURGERY, 2022, 92 (04) : 674 - 684