Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures

被引:1
|
作者
Usta, Emirhan [1 ]
Akpolat, Ahmet O. [2 ]
Kahraman, Ahmet N. [3 ]
Kara, Adnan [4 ]
Oc, Yunus [5 ]
Kilinc, Bekir E. [6 ]
机构
[1] Urfa Traning & Res Hosp, Dept Orthopaed & Traumatol, Sanliurfa, Turkey
[2] Hlth Sci Univ, Istanbul Fatih Sultan Mehmet Training & Res Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[3] Hlth Sci Univ, Istanbul Fatih Sultan Mehmet Training & Res Hosp, Dept Radiol, Istanbul, Turkey
[4] Medipol Hosp, Orthopaed & Traumatol, Istanbul, Turkey
[5] Beykent Univ, Dept Orthopaed & Traumatol, Sch Med, Istanbul, Turkey
[6] Univ Hlth Sci, Fatih Sultan Mehmet Training & Res Hosp, Orthopaed Surg & Traumatolagy, Istanbul, Turkey
关键词
coronal malposition; tenosynovitis; flexor pollicis longus; volar locking plate; distal radius fracture; COMPLICATIONS; FIXATION;
D O I
10.7759/cureus.26444
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: Literature does not show any studies regarding plate placement problems in the coronal plane of patients with volar plating due to distal radius fracture diagnosis. We aimed to investigate the functional and laboratory results of the coronal malposition of the volar locking plate in patients with distal radius fracture treated with internal fixation. Methods: In this retrospective study, we included patients who had volar plate fixation, were aged between 18 and 80, had no pathological fracture, had a minimum of six months of follow-up, and had the same rehabilitation protocol. We consider the angle subtended on the coronal axis between the distal radius long axis and the distal radius locking plate as coronal malposition. We named the coronal malposition angle the "AYE Angle." Patients with an AYE angle of over 1 degree were evaluated under group 1. Patients with an AYE angle of 0-1 degrees were evaluated under group 2. Radiological parameters were taken from AP-Lateral X-ray views. Superficial University System of Georgia (USG) examinations were applied to detect tendon problems. The DASH and QUICK-DASH scoring systems were used for clinical evaluation. Grip strength was measured with a dynamometer in all patients. All results were compared between the two groups. Results: Thirteen patients were female and 27 patients were male. Nineteen patients who had coronal malposition were added to group 1, while 21 patients who had no coronal malposition were added to group 2. Fifteen patients had normal USG results in group 2, while 18 patients had edema around the flexor pollicis longus (FPL) tendon as a result of USG in group 1. Statistically, a significant difference was detected between the two groups in terms of the amount of tenosynovitis around FPL (p=0.01). A statistically significant relationship was found between USG grading and malposition grading. The study revealed that a higher rate of USG grade 2 was found in patients with malposition grade 2 (90.9%), while a higher rate of USG grade 1 (50%) was observed in patients with malposition grade 1 (p=0.01). A statistically significant difference was not found between Soong grading and USG in terms of the level of tenosynovitis around the FPL tendon. The amount of tenosynovitis detected around the FPL tendon was 62.5% for Soong and grade 0 level, 60.7% for grade 1 level, and 50% for grade 2 level. There was no statistically significant difference between the two groups in the DASH and QUICK-DASH scoring systems (p=0.96). There was no statistically significant difference between the two groups in the grip strength (p=0.52). Conclusion: Coronal plate position in the treatment of the distal radius fracture is important to avoid potential flexor tendon problems. The volar plate position should be adjusted properly both in the coronal and sagittal axes.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate
    Quadlbauer, Stefan
    Pezzei, Ch.
    Jurkowitsch, J.
    Rosenauer, R.
    Pichler, A.
    Schaettin, S.
    Hausner, T.
    Leixnering, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (12) : 1773 - 1782
  • [32] Volar locking plate (VLP) versus non-locking plate (NLP) in the treatment of die-punch fractures of the distal radius, an observational study
    Zhang, Xiong
    Hu, Chunhe
    Yu, Kunlun
    Bai, Jiangbo
    Tian, Dehu
    Xu, Yi
    Zhang, Bing
    INTERNATIONAL JOURNAL OF SURGERY, 2016, 34 : 142 - 147
  • [33] Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate
    Stefan Quadlbauer
    Ch. Pezzei
    J. Jurkowitsch
    R. Rosenauer
    A. Pichler
    S. Schättin
    T. Hausner
    M. Leixnering
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 1773 - 1782
  • [34] Volar Locking Plate Fixation for Intra-Articular Distal Radius Fractures with Volar Lunate Facet Fragments Distal to the Watershed Line
    Nanno, Mitsuhiko
    Kodera, Norie
    Tomori, Yuji
    Takai, Shinro
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2020, 87 (01) : 24 - 31
  • [35] Volar plate fixation of distal radius fractures
    Demirbas, Emrah Riza
    Ugras, Ali Akin
    Kaya, Ibrahim
    Sungur, Ibrahim
    Kural, Cemal
    Cetinus, Ercan
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2012, 18 (02): : 162 - 166
  • [36] A systematic review of volar locking plate removal after distal radius fracture
    Yamamoto, Michiro
    Fujihara, Yuki
    Fujihara, Nasa
    Hirata, Hitoshi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (12): : 2650 - 2656
  • [37] What are the ideal screw lengths in volar locking plate fixation for distal radius fractures?
    Kilian, M.
    Simkovic, P.
    Zamborsky, R.
    Skoda, A.
    Labas, P.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2019, 120 (07): : 505 - 509
  • [38] Functional and radiological outcome of distal radius fractures stabilized by volar-locking plate with a minimum follow-up of 1 year
    Quadlbauer, Stefan
    Pezzei, Ch.
    Jurkowitsch, J.
    Rosenauer, R.
    Pichler, A.
    Schaettin, S.
    Hausner, T.
    Leixnering, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (06) : 843 - 852
  • [39] Volar Plate-Suture Fixation in the Treatment of Volar Rim Fractures of the Distal Radius
    Carney, John
    Bigach, Stephen
    Goedderz, Cody
    Gerlach, Erik
    Marx, Jeremy
    Kalainov, David
    JOURNAL OF WRIST SURGERY, 2025, 14 (01) : 57 - 62
  • [40] Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis
    Gouk, Conor J. C.
    Bindra, Randip R.
    Tarrant, Drew J.
    Thomas, Michael J. E.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (09) : 954 - 960