Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures

被引:1
|
作者
Usta, Emirhan [1 ]
Akpolat, Ahmet O. [2 ]
Kahraman, Ahmet N. [3 ]
Kara, Adnan [4 ]
Oc, Yunus [5 ]
Kilinc, Bekir E. [6 ]
机构
[1] Urfa Traning & Res Hosp, Dept Orthopaed & Traumatol, Sanliurfa, Turkey
[2] Hlth Sci Univ, Istanbul Fatih Sultan Mehmet Training & Res Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[3] Hlth Sci Univ, Istanbul Fatih Sultan Mehmet Training & Res Hosp, Dept Radiol, Istanbul, Turkey
[4] Medipol Hosp, Orthopaed & Traumatol, Istanbul, Turkey
[5] Beykent Univ, Dept Orthopaed & Traumatol, Sch Med, Istanbul, Turkey
[6] Univ Hlth Sci, Fatih Sultan Mehmet Training & Res Hosp, Orthopaed Surg & Traumatolagy, Istanbul, Turkey
关键词
coronal malposition; tenosynovitis; flexor pollicis longus; volar locking plate; distal radius fracture; COMPLICATIONS; FIXATION;
D O I
10.7759/cureus.26444
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: Literature does not show any studies regarding plate placement problems in the coronal plane of patients with volar plating due to distal radius fracture diagnosis. We aimed to investigate the functional and laboratory results of the coronal malposition of the volar locking plate in patients with distal radius fracture treated with internal fixation. Methods: In this retrospective study, we included patients who had volar plate fixation, were aged between 18 and 80, had no pathological fracture, had a minimum of six months of follow-up, and had the same rehabilitation protocol. We consider the angle subtended on the coronal axis between the distal radius long axis and the distal radius locking plate as coronal malposition. We named the coronal malposition angle the "AYE Angle." Patients with an AYE angle of over 1 degree were evaluated under group 1. Patients with an AYE angle of 0-1 degrees were evaluated under group 2. Radiological parameters were taken from AP-Lateral X-ray views. Superficial University System of Georgia (USG) examinations were applied to detect tendon problems. The DASH and QUICK-DASH scoring systems were used for clinical evaluation. Grip strength was measured with a dynamometer in all patients. All results were compared between the two groups. Results: Thirteen patients were female and 27 patients were male. Nineteen patients who had coronal malposition were added to group 1, while 21 patients who had no coronal malposition were added to group 2. Fifteen patients had normal USG results in group 2, while 18 patients had edema around the flexor pollicis longus (FPL) tendon as a result of USG in group 1. Statistically, a significant difference was detected between the two groups in terms of the amount of tenosynovitis around FPL (p=0.01). A statistically significant relationship was found between USG grading and malposition grading. The study revealed that a higher rate of USG grade 2 was found in patients with malposition grade 2 (90.9%), while a higher rate of USG grade 1 (50%) was observed in patients with malposition grade 1 (p=0.01). A statistically significant difference was not found between Soong grading and USG in terms of the level of tenosynovitis around the FPL tendon. The amount of tenosynovitis detected around the FPL tendon was 62.5% for Soong and grade 0 level, 60.7% for grade 1 level, and 50% for grade 2 level. There was no statistically significant difference between the two groups in the DASH and QUICK-DASH scoring systems (p=0.96). There was no statistically significant difference between the two groups in the grip strength (p=0.52). Conclusion: Coronal plate position in the treatment of the distal radius fracture is important to avoid potential flexor tendon problems. The volar plate position should be adjusted properly both in the coronal and sagittal axes.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Treatment of unstable distal radius fractures with the volar locking plate
    Minegishi, Hanae
    Dohi, Osamu
    An, Soukan
    Sato, Hidetsugu
    UPSALA JOURNAL OF MEDICAL SCIENCES, 2011, 116 (04) : 280 - 284
  • [2] The volar locking plate for extension fractures of the distal radius
    Pillukat, T.
    Fuhrmann, R.
    Windolf, J.
    van Schoonhoven, J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (01): : 47 - 63
  • [3] Breakage of volar locking plate system for distal radius fractures
    Kawanishi, Syohei
    Gato, Uasushi
    Nakai, Tsuyoshi
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (S 1): : 71 - 77
  • [4] Results of volar locking plating for unstable distal radius fractures
    Sugun, Tahir Sadik
    Gurbuz, Yusuf
    Ozaksar, Kemal
    Toros, Tulgar
    Kayalar, Murat
    Bal, Emin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2012, 46 (01) : 22 - 25
  • [5] Comparison of the Orientation Angles of Volar Locking Plate Distal Ulnar Locking Screw for Distal Radius Fractures
    Abe, Shingo
    Shimada, Toshiki
    Murase, Tsuyoshi
    Kuriyama, Kohji
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (04): : 389.e1 - 389.e13
  • [6] Risk of Volar Locking Plate Removal After Distal Radius Fractures: Time-to-Event Analysis
    Holc, Fernando
    Victorica, Pedro Bronenberg
    Avanzi, Rocio
    Huespe, Ivan A.
    De Carli, Pablo
    Boretto, Jorge G.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (10): : 1011 - 1017
  • [7] Prospective study of distal radius fractures treated with a volar locking plate system
    Osada, Denju
    Kamei, Shuzo
    Masuzaki, Koichiro
    Takai, Morimitsu
    Kameda, Masahiro
    Tamai, Kazuya
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (05): : 691 - 700
  • [8] Teardrop Alignment Changes After Volar Locking Plate Fixation of Distal Radius Fractures With Volar Ulnar Fragments
    McCarty, Justin C.
    Cross, Rachel E.
    Laane, Charlotte L. E.
    Hoftiezer, Yannick Albert J.
    Gavagnin, Aquiles
    Regazzoni, Pietro
    Dell'Oca, Alberto Fernandez
    Jupiter, Jesse B.
    Bhashyam, Abhiram R.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024,
  • [9] Volar Locking Plate Fixation for Distal Radius Fractures Distal to the Watershed Line with an Intact Lunate Volar Rim
    Cha, Soo Min
    Shin, Hyun Dae
    Kim, Seung Won
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (06) : 708 - 716
  • [10] Outcomes of Primary Volar Locking Plate Fixation of Open Distal Radius Fractures
    Joo, Min Su
    Kang, Hong Je
    Yu, Hyun Kyu
    Lee, Jae Sung
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2022, 27 (03) : 517 - 523