Atomic spectrometry update. Atomic mass spectrometry

被引:10
作者
Bacon, Jeffrey R. [1 ]
Linge, Kathryn L. [2 ]
Parrish, Randall R. [3 ,4 ]
Van Vaeck, Luc [5 ]
机构
[1] Macaulay Inst, Aberdeen AB15 8QH, Scotland
[2] Curtin Univ Technol, Dept Appl Chem, Curtin Water Qual Res Ctr, Perth, WA, Australia
[3] Univ Leicester, Dept Geol, Nottingham NG12 5GG, England
[4] Kingsley Dunham Ctr, NERC Isotope Geosci Lab, Nottingham NG12 5GG, England
[5] Univ Antwerp, Dept Chem, Micro & Trace Anal Ctr, B-2610 Antwerp, Belgium
基金
英国自然环境研究理事会;
关键词
D O I
10.1039/b808563n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The review this year is dominated by the large number of publications on AMS, ICP-MS and SIMS. The increasing number of new AMS installations bears witness to the increasing interest in the technique now that smaller and simpler systems are becoming more widely available. Although high- energy systems still have an important role to play, each of the new systems was compact and of relatively low- energy. The development of ion sources that can accept gaseous samples has lowered the sample size requirement for radiocarbon analysis such that it is now little more than the background level. Contamination therefore has become a major issue. The numerous papers on improvements to SIMS analysis demonstrate the important role the technique plays in materials science. Unlike for most of the techniques covered, fundamental studies on SIMS analysis abound with particular attention being paid to understanding the ionization processes and the representativeness of the measured ion beam. Quantum chemistry calculations have been used to determine the fundamental processes occurring in cell ICP- MS. This approach contrasted with the empirical studies that are normally undertaken. Although many applications are still being published using collision and/ or reaction cell ICP- MS, there were fewer novel or fundamental studies than in previous years. This suggests that cell ICP-MS is becoming a more routine method of analysis. The same can probably also be said of hyphenated ICP- MS methods for speciation, which continues to grow in importance but which is very much at the applied end of the spectrum. Speciation is notable in that it cuts across a number of MS techniques and conventional organic MS techniques are increasingly being investigated for structure determination of organometallic species. Each year seems to find further expansion of MC- ICP-MS into 'non-traditional' isotope analysis. This was the year for Ti isotope analysis.
引用
收藏
页码:1130 / 1162
页数:33
相关论文
共 259 条
[1]   Determination of 238Pu in plutonium bearing fuels by thermal ionization mass spectrometry [J].
Aggarwal, S. K. ;
Alamelu, D. ;
Khodade, P. S. ;
Shah, P. M. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 273 (03) :775-778
[2]  
Aggarwal SK, 2007, RADIOCHIM ACTA, V95, P233, DOI 10.1524/racl.2007.95.4.233
[3]   Effect of radioactive decay of Pu isotopes on the determination of Pu concentration with high accuracy by isotope dilution mass spectrometry (IDMS) and isotope dilution alpha spectrometry (IDAS) [J].
Alamelu, D. ;
Aggarwal, S. K. .
JOURNAL OF ALLOYS AND COMPOUNDS, 2007, 444 :643-646
[4]   A novel method for trace uranium determination in plutonium by thermal ionisation mass spectrometry [J].
Alamelu, D. ;
Aggarwal, S. K. .
JOURNAL OF ALLOYS AND COMPOUNDS, 2007, 444 :640-642
[5]   Measurements of 36Cl with a gas-filled magnet at the Uppsala tandem laboratory [J].
Alfimov, V. ;
Possnert, G. ;
Aldahan, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 259 (01) :199-203
[6]   Online standard additions calibration of transient signals for inductively coupled plasma mass spectrometry [J].
Antler, Margaret ;
Maxwell, E. Jane ;
Duford, David A. ;
Salin, E. D. .
ANALYTICAL CHEMISTRY, 2007, 79 (02) :688-694
[7]   A new demountable hydrofluoric acid resistant triple mode sample introduction system for ICP-AES and ICP-MS [J].
Asfaw, Alemayehu ;
Wibetoe, Grethe .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (02) :158-163
[8]   Improvement of the 36Cl-AMS system at MALT using a Monte Carlo ion-trajectory simulation in a gas-filled magnet [J].
Aze, Takahiro ;
Matsuzaki, Hiroyuki ;
Matsumura, Hiroshi ;
Nagai, Hisao ;
Fujimura, Masatsugu ;
Noguchi, Mayumi ;
Hongo, Yayoi ;
Yokoyama, Yusuke .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 259 (01) :144-148
[9]   Atomic spectrometry update. Atomic mass spectrometry [J].
Bacon, Jeffrey R. ;
Linge, Kathryn L. ;
Parrish, Randall R. ;
Van Vaeck, Luc .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (08) :973-1006
[10]  
Barozzi M, 2007, REV ADV MATER SCI, V15, P56