Acceleration tests of a 3 GHz proton linear accelerator (LIBO) for hadrontherapy

被引:24
作者
De Martinis, C. [1 ,2 ]
Glove, D. [1 ,2 ]
Amaldi, U. [3 ]
Berra, P. [3 ]
Crandall, K. [3 ]
Mauri, M. [3 ]
Weiss, M. [3 ]
Zennaro, R. [3 ]
Rosso, E. [4 ]
Szeless, B. [4 ]
Vretenar, M. [4 ]
Masullo, M. R. [5 ,6 ]
Vaccaro, V. [5 ,6 ]
Calabretta, L. [7 ]
Rovelli, A. [7 ]
机构
[1] Univ Milan, Milan, Italy
[2] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[3] TERA Fdn, Novara, Italy
[4] CERN, Geneva, Switzerland
[5] Univ Naples Federico II, Naples, Italy
[6] Ist Nazl Fis Nucl, I-80125 Naples, Italy
[7] INFN LNS, Catania, Italy
关键词
Linac; Cyclotron; Booster; Cyclinac; Proton therapy;
D O I
10.1016/j.nima.2012.04.017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes the acceleration tests performed at the Catania LNS Laboratory on a 3 GHz linac module of the side coupled type, which boosts the proton energy of a beam extracted from a cyclotron from 62 to 72 MeV. The output proton energy was measured with two devices: a NaI(Tl) crystal and a bending magnet. The experimental spectra are in good agreement with the calculated ones. From their shape it is obtained that (18 +/- 3.0)% of the transmitted protons fall in a +/-2 MeV interval centered around 72 MeV. This result is in good agreement with the 20% value derived from the simulation of the acceleration process. The measured energy of the accelerated protons was used to check that the shunt impedance of the structure is equal to the computed one within 3%. This was the first time that a 3 GHz structure has been used to accelerate protons, and the results of the tests have demonstrated that a high frequency linac can be used as a cyclotron booster. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 15
页数:6
相关论文
共 17 条
  • [1] LIBO - a linac-booster for protontherapy: construction and tests of a prototype
    Amaldi, U
    Berra, P
    Crandall, K
    Toet, D
    Weiss, M
    Zennaro, R
    Rosso, E
    Szeless, B
    Vretenar, M
    Cicardi, C
    De Martinis, C
    Giove, D
    Davino, D
    Masullo, MR
    Vaccaro, V
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 521 (2-3) : 512 - 529
  • [2] Amaldi U, 2009, REV ACCEL SCI TECH, V2, P111, DOI 10.1142/S179362680900020X
  • [3] Berra P., 2005, THESIS U C BERNARD L
  • [4] BERRA P, 2000, P EUR PART ACC C EPA, P2495
  • [5] Calabretta L., 1996, NUCL INSTRUMENTS M A, pA382
  • [6] Caporaso GJ, 2009, REV ACCEL SCI TECH, V2, P253, DOI 10.1142/S1793626809000235
  • [7] A 62-MeV proton beam for the treatment of ocular melanoma at Laboratori Nazionali del Sud-INFN
    Cirrone, GAP
    Cuttone, G
    Lojacono, PA
    Lo Nigro, S
    Mongelli, V
    Patti, IV
    Privitera, G
    Raffaele, L
    Rifuggiato, D
    Sabini, MG
    Salamone, V
    Spatola, C
    Valastro, LM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 860 - 865
  • [8] Clarke J.A., 1998, European Particle Accelerators Conference Proceedings, P2374
  • [9] Crandall K., PROGRAM LINAC HAS BE
  • [10] Ferrari A, 2005, CERN-2005-10, INFN/TC_05/11, SLAC-R-773