A novel energy mapping approach for CT-based attenuation correction in PET

被引:11
作者
Teimourian, B. [1 ,2 ]
Ay, M. R. [1 ,3 ,4 ]
Zafarghandi, M. Shamsaie [2 ]
Ghafarian, P. [5 ,6 ]
Ghadiri, H. [1 ,4 ]
Zaidi, H. [7 ,8 ,9 ]
机构
[1] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[2] Amirkabir Univ Technol, Tehran Polytech, Fac Phys & Nucl Engn, Tehran, Iran
[3] Univ Tehran Med Sci, Res Inst Nucl Med, Tehran, Iran
[4] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Telemed Res Ctr, NRITLD, Masih Daneshvari Hosp, Tehran, Iran
[6] Shahid Beheshti Univ Med Sci, Chron Resp Dis Res Ctr, NRITLD, Masih Daneshvari Hosp, Tehran, Iran
[7] Univ Hosp Geneva, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[8] Univ Geneva, Geneva Neurosci Ctr, CH-1211 Geneva, Switzerland
[9] Univ Groningen, Univ Med Ctr Gronigen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
基金
瑞士国家科学基金会;
关键词
PET/CT; attenuation correction; attenuation map; energy-mapping; dual-energy CT; ARTIFACTS; IMAGES; TOMOGRAPHY;
D O I
10.1118/1.3694108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Dual-energy CT (DECT) is arguably the most accurate energy mapping technique in CT-based attenuation correction (CTAC) implemented on hybrid PET/CT systems. However, this approach is not attractive for clinical use owing to increased patient dose. The authors propose a novel energy mapping approach referred to as virtual DECT (VDECT) taking advantage of the DECT formulation but using CT data acquired at a single energy (kV(P)). For this purpose, the CT image acquired at one energy is used to generate the CT image at a second energy using calculated kV(P) conversion curves derived from phantom studies. Methods: The attenuation map (mu-map) at 511 keV was generated for the XCAT phantom and clinical studies using the bilinear, DECT, and VDECT techniques. The generated mu-maps at 511 keV are compared to the reference derived from the XCAT phantom serving as ground truth. PET data generated from a predefined activity map for the XCAT phantom were then corrected for attenuation using mu-maps generated using the different energy mapping approaches. In addition, the generated mu-maps using the above described methods for a cylindrical polyethylene phantom containing different concentrations of K2HPO4 in water were compared to actual attenuation coefficients. Likewise, CT images of five clinical whole-body studies were used to generate mu-maps using the various energy-mapping approaches were compared with mu-maps acquired at 511 keV using Ge-68/Ga-68 rod sources for the clinical studies. Results: The results of phantom studies demonstrate that the proposed method is more accurate than the bilinear technique. All three mu-maps yielded almost similar results for soft and lung tissues whereas for bone tissues, the DECT and the VDECT methods produced a much smaller mean relative difference (3.0% and 2.8%, respectively) than the bilinear approach (11.8%). Likewise, the comparison of PET images corrected for attenuation using the various methods showed that the proposed method provides better accuracy (6.5%) than the bilinear method (13.4%). Clinical studies further demonstrated that, compared to the bilinear method, the VDECT approach has better agreement for bony structures with the DECT technique (1.5% versus 8.9%) and transmission scanning (8.8% versus 17.7%). Conclusions: It was concluded that the proposed method outperforms the bilinear method especially in bony structures. Further evaluation using a large clinical PET/CT database is underway to evaluate the potential of the technique in a clinical setting. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3694108]
引用
收藏
页码:2078 / 2089
页数:12
相关论文
共 32 条
[21]   Statistical Sinogram Restoration in Dual-Energy CT for PET Attenuation Correction [J].
Noh, Joonki ;
Fessler, Jeffrey A. ;
Kinahan, Paul E. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) :1688-1702
[22]   Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT [J].
Osman, MM ;
Cohade, C ;
Nakamoto, Y ;
Wahl, RL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :603-606
[23]   Partial Volume Correction Strategies in PET [J].
Rousset, Olivier ;
Rahmim, Arman ;
Alavi, Abass ;
Zaidi, Habib .
PET CLINICS, 2007, 2 (02) :235-249
[24]   Positron flight in human tissues and its influence on PET image spatial resolution [J].
Sánchez-Crespo, A ;
Andreo, P ;
Larsson, SA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (01) :44-51
[25]   Realistic CT simulation using the 4D XCAT phantom [J].
Segars, W. P. ;
Mahesh, M. ;
Beck, T. J. ;
Frey, E. C. ;
Tsui, B. M. W. .
MEDICAL PHYSICS, 2008, 35 (08) :3800-3808
[26]   Annihilation photon acollinearity in PET: volunteer and phantom FDG studies [J].
Shibuya, Kengo ;
Yoshida, Eiji ;
Nishikido, Fumihiko ;
Suzuki, Toshikazu ;
Tsuda, Tomoaki ;
Inadama, Naoko ;
Yamaya, Taiga ;
Murayama, Hideo .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (17) :5249-5261
[27]   STIR: software for tomographic image reconstruction release 2 [J].
Thielemans, Kris ;
Tsoumpas, Charalampos ;
Mustafovic, Sanida ;
Beisel, Tobias ;
Aguiar, Pablo ;
Dikaios, Nikolaos ;
Jacobson, Matthew W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (04) :867-883
[28]   A method for calibrating the CT-based attenuation correction of PET in human tissue [J].
Watson, CC ;
Rappoport, V ;
Faul, D ;
Townsend, DW ;
Carney, JP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :102-107
[29]   Noise and Bias Properties of Monoenergetic Images from DECT used for Attenuation Correction with PET/CT and SPECT/CT [J].
Xia, Ting ;
Alessio, Adam M. ;
Kinahan, Paul E. .
MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
[30]   Scatter modelling and compensation in emission tomography [J].
Zaidi, H ;
Koral, KF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (05) :761-782