A novel energy mapping approach for CT-based attenuation correction in PET

被引:11
作者
Teimourian, B. [1 ,2 ]
Ay, M. R. [1 ,3 ,4 ]
Zafarghandi, M. Shamsaie [2 ]
Ghafarian, P. [5 ,6 ]
Ghadiri, H. [1 ,4 ]
Zaidi, H. [7 ,8 ,9 ]
机构
[1] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[2] Amirkabir Univ Technol, Tehran Polytech, Fac Phys & Nucl Engn, Tehran, Iran
[3] Univ Tehran Med Sci, Res Inst Nucl Med, Tehran, Iran
[4] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Telemed Res Ctr, NRITLD, Masih Daneshvari Hosp, Tehran, Iran
[6] Shahid Beheshti Univ Med Sci, Chron Resp Dis Res Ctr, NRITLD, Masih Daneshvari Hosp, Tehran, Iran
[7] Univ Hosp Geneva, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[8] Univ Geneva, Geneva Neurosci Ctr, CH-1211 Geneva, Switzerland
[9] Univ Groningen, Univ Med Ctr Gronigen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
基金
瑞士国家科学基金会;
关键词
PET/CT; attenuation correction; attenuation map; energy-mapping; dual-energy CT; ARTIFACTS; IMAGES; TOMOGRAPHY;
D O I
10.1118/1.3694108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Dual-energy CT (DECT) is arguably the most accurate energy mapping technique in CT-based attenuation correction (CTAC) implemented on hybrid PET/CT systems. However, this approach is not attractive for clinical use owing to increased patient dose. The authors propose a novel energy mapping approach referred to as virtual DECT (VDECT) taking advantage of the DECT formulation but using CT data acquired at a single energy (kV(P)). For this purpose, the CT image acquired at one energy is used to generate the CT image at a second energy using calculated kV(P) conversion curves derived from phantom studies. Methods: The attenuation map (mu-map) at 511 keV was generated for the XCAT phantom and clinical studies using the bilinear, DECT, and VDECT techniques. The generated mu-maps at 511 keV are compared to the reference derived from the XCAT phantom serving as ground truth. PET data generated from a predefined activity map for the XCAT phantom were then corrected for attenuation using mu-maps generated using the different energy mapping approaches. In addition, the generated mu-maps using the above described methods for a cylindrical polyethylene phantom containing different concentrations of K2HPO4 in water were compared to actual attenuation coefficients. Likewise, CT images of five clinical whole-body studies were used to generate mu-maps using the various energy-mapping approaches were compared with mu-maps acquired at 511 keV using Ge-68/Ga-68 rod sources for the clinical studies. Results: The results of phantom studies demonstrate that the proposed method is more accurate than the bilinear technique. All three mu-maps yielded almost similar results for soft and lung tissues whereas for bone tissues, the DECT and the VDECT methods produced a much smaller mean relative difference (3.0% and 2.8%, respectively) than the bilinear approach (11.8%). Likewise, the comparison of PET images corrected for attenuation using the various methods showed that the proposed method provides better accuracy (6.5%) than the bilinear method (13.4%). Clinical studies further demonstrated that, compared to the bilinear method, the VDECT approach has better agreement for bony structures with the DECT technique (1.5% versus 8.9%) and transmission scanning (8.8% versus 17.7%). Conclusions: It was concluded that the proposed method outperforms the bilinear method especially in bony structures. Further evaluation using a large clinical PET/CT database is underway to evaluate the potential of the technique in a clinical setting. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3694108]
引用
收藏
页码:2078 / 2089
页数:12
相关论文
共 32 条
[1]   Reduction of dental filling metallic artifacts in CT-based attenuation correction of PET data using weighted virtual sinograms optimized by a genetic algorithm [J].
Abdoli, Mehrsima ;
Ay, Mohammad Reza ;
Ahmadian, Alireza ;
Dierckx, Rudi A. J. O. ;
Zaidi, Habib .
MEDICAL PHYSICS, 2010, 37 (12) :6166-6177
[2]   Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm [J].
Ahmadian, Alireza ;
Ay, Mohammad R. ;
Bidgoli, Javad H. ;
Sarkar, Saeed ;
Zaidi, Habib .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (10) :1812-1823
[3]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[4]  
[Anonymous], 12 MED C MED BIOL EN
[5]  
[Anonymous], 1998, XCOM PHOTON CROSS SE
[6]   Comparative Assessment of Energy-Mapping Approaches in CT-Based Attenuation Correction for PET [J].
Ay, Mohammad R. ;
Shirmohammad, Maryam ;
Sarkar, Saeed ;
Rahmim, Arman ;
Zaidi, Habib .
MOLECULAR IMAGING AND BIOLOGY, 2011, 13 (01) :187-198
[7]   Computed tomography-based attenuation correction in neurological positron emission tomography: evaluation of the effect of the X-ray tube voltage on quantitative analysis [J].
Ay, MR ;
Zaidi, H .
NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (04) :339-346
[8]  
Bai CY, 2003, J NUCL MED, V44, P1855
[9]   A generalized model for the conversion from CT numbers to linear attenuation coefficients [J].
Bai, CY ;
Shao, L ;
Da Silva, AJ ;
Zhao, Z .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1510-1515
[10]  
BEYER T, 1994, NUCLEAR SCIENCE SYMPOSIUM & MEDICAL IMAGING CONFERENCE - 1994 IEEE CONFERENCE RECORD, VOLS 1-4, P1573