Transcarotid aortic valve-in-valve implantation for degenerated stentless aortic root conduits with severe regurgitation: a case series

被引:13
作者
Huber, Christoph [1 ]
Praz, Fabien [2 ]
O'Sullivan, Crochan J. [3 ]
Langhammer, Bettina [1 ]
Gloekler, Steffen [2 ]
Stortecky, Stefan [2 ]
von Allmen, Regula S. [1 ]
Meier, Bernhard [2 ]
Carrel, Thierry [1 ]
Englberger, Lars [1 ]
Windecker, Stephan [2 ]
Wenaweser, Peter [2 ]
机构
[1] Univ Hosp Bern, Dept Cardiovasc Surg, CH-3010 Bern, Switzerland
[2] Univ Hosp Bern, Dept Cardiol, CH-3010 Bern, Switzerland
[3] Stadtspital Triemli, Dept Cardiol, Zurich, Switzerland
关键词
Transcatheter aortic valve implantation; Valve-in-valve; Aortic regurgitation; Valvular heart disease; CLINICAL-OUTCOMES; LOCAL-ANESTHESIA; ASCENDING AORTA; CAROTID-ARTERY; TRANSCATHETER; REPLACEMENT; ACCESS; SYSTEM;
D O I
10.1093/icvts/ivv053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Transcatheter aortic valve implantation (TAVI) is routinely performed via the transfemoral and the transapical route. Subclavian and direct aortic access are described alternatives for TAVI. Recently, the transcarotid approach has been shown to be feasible among patients with limited vascular access and severe native aortic valve stenosis. We aim to investigate the feasibility of transcatheter aortic valve-in-valve implantation via the transcarotid access in patients with severe aortic regurgitation due to degenerated stentless Shelhigh conduits using the 29 mm Medtronic CoreValve bioprosthesis. METHODS: Three patients with complex vascular anatomy undergoing transcatheter valve-in-valve implantation via the transcarotid route were enrolled in the study. The procedure was performed under general anaesthesia using surgical cut-down to facilitate vascular access. Immediate procedural results as well as echocardiographic and clinical outcomes after 30 days and 6 months of the follow-up were recorded and analysed. RESULTS: All three patients underwent unproblematic TAVI and experienced dramatic improvement of symptoms. Mean transvalvular gradient was 3, 6 and 11 mmHg, respectively. Effective orifice area ranged between 1.7 and 2.2 cm(2). Only mild paravalvular regurgitation was detected by echocardiography after 30 days of the follow-up. CONCLUSIONS: The transcarotid approach can be safely performed for valve-in-valve procedures using the Medtronic CoreValve in patients with limited vascular access. It enables accurate positioning and implantation of the prosthesis.
引用
收藏
页码:694 / 700
页数:7
相关论文
共 18 条
[1]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[2]   Transcatheter aortic valve implantation through carotid artery access under local anaesthesia [J].
Azmoun, Alexandre ;
Amabile, Nicolas ;
Ramadan, Ramzi ;
Ghostine, Said ;
Caussin, Christophe ;
Fradi, Sahbi ;
Raoux, Francois ;
Brenot, Philippe ;
Nottin, Remi ;
Deleuze, Philippe .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 46 (04) :693-698
[3]   First successful trans-catheter aortic valve implantation through ascending aorta using Edwards SAPIEN THV system [J].
Bapat, Vinayak ;
Thomas, Martyn ;
Hancock, Jane ;
Wilson, Karen .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (06) :811-813
[4]   Transcatheter Aortic Valve Implantation through the Ascending Aorta: An Alternative Option for No-Access Patients [J].
Bauernschmitt, Robert ;
Schreiber, Christian ;
Bleiziffer, Sabine ;
Ruge, Hendrik ;
Mazzitelli, Domenico ;
Hutter, Andrea ;
Tassani, Peter ;
Lange, Ruediger .
HEART SURGERY FORUM, 2009, 12 (01) :E63-E64
[5]   Expanding the Eligibility for Transcatheter Aortic Valve Implantation The Trans-Subclavian Retrograde Approach Using the III Generation CoreValve Revalving System [J].
Fraccaro, Chiara ;
Napodano, Massimo ;
Tarantini, Giuseppe ;
Gasparetto, Valeria ;
Gerosa, Gino ;
Bianco, Roberto ;
Bonato, Raffaele ;
Pittarello, Demetrio ;
Isabella, Giambattista ;
Iliceto, Sabino ;
Ramondo, Angelo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) :828-833
[6]   Direct-access valve replacement - A novel approach for off-pump valve implantation using valved stents [J].
Huber, CH ;
Cohn, LH ;
von Segesser, LK .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (02) :366-370
[7]   Transapical Versus Transfemoral Aortic Valve Implantation: A Comparison of Survival and Safety [J].
Johansson, Malin ;
Nozohoor, Shahab ;
Kimblad, Per Ola ;
Harnek, Jan ;
Olivecrona, Goran K. ;
Sjogren, Johan .
ANNALS OF THORACIC SURGERY, 2011, 91 (01) :57-63
[8]   Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement [J].
Kodali, Susheel K. ;
Williams, Mathew R. ;
Smith, Craig R. ;
Svensson, Lars G. ;
Webb, John G. ;
Makkar, Raj R. ;
Fontana, Gregory P. ;
Dewey, Todd M. ;
Thourani, Vinod H. ;
Pichard, Augusto D. ;
Fischbein, Michael ;
Szeto, Wilson Y. ;
Lim, Scott ;
Greason, Kevin L. ;
Teirstein, Paul S. ;
Malaisrie, S. Chris ;
Douglas, Pamela S. ;
Hahn, Rebecca T. ;
Whisenant, Brian ;
Zajarias, Alan ;
Wang, Duolao ;
Akin, Jodi J. ;
Anderson, William N. ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) :1686-1695
[9]   Transcatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis [J].
Makkar, Raj R. ;
Fontana, Gregory P. ;
Jilaihawi, Hasan ;
Kapadia, Samir ;
Pichard, Augusto D. ;
Douglas, Pamela S. ;
Thourani, Vinod H. ;
Babaliaros, Vasilis C. ;
Webb, John G. ;
Herrmann, Howard C. ;
Bavaria, Joseph E. ;
Kodali, Susheel ;
Brown, David L. ;
Bowers, Bruce ;
Dewey, Todd M. ;
Svensson, Lars G. ;
Tuzcu, Murat ;
Moses, Jeffrey W. ;
Williams, Matthew R. ;
Siegel, Robert J. ;
Akin, Jodi J. ;
Anderson, William N. ;
Pocock, Stuart ;
Smith, Craig R. ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) :1696-1704
[10]   Implantation of a Sapien XT Aortic Bioprosthesis through the Left Carotid Artery [J].
Modine, Thomas ;
Sudre, Arnaud ;
Amr, Gilles ;
Delhaye, Cedric ;
Koussa, Mohamad .
JOURNAL OF CARDIAC SURGERY, 2014, 29 (03) :337-339