A new automated quantification algorithm for the detection and evaluation of focal liver lesions with contrast-enhanced ultrasound

被引:45
作者
Gatos, Ilias [1 ]
Tsantis, Stavros [1 ]
Spiliopoulos, Stavros [2 ]
Skouroliakou, Aikaterini [3 ]
Theotokas, Ioannis [4 ]
Zoumpoulis, Pavlos [4 ]
Hazle, John D. [5 ]
Kagadis, George C. [1 ,5 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, GR-26504 Rion, Greece
[2] Univ Patras, Sch Med, Dept Radiol, GR-26504 Rion, Greece
[3] Technol Educ Inst Athens, Dept Energy Technol Engn, Athens 12210, Greece
[4] Diagnost Echotomog SA, GR-14561 Kifisia, Greece
[5] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
focal liver lesions; contrast-enhanced ultrasound; time intensity curves; segmentation; classification; CLINICAL-PRACTICE RECOMMENDATIONS; GUIDELINES; CEUS;
D O I
10.1118/1.4921753
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Detect and classify focal liver lesions (FLLs) from contrast-enhanced ultrasound (CEUS) imaging by means of an automated quantification algorithm. Methods: The proposed algorithm employs a sophisticated segmentation method to detect and contour focal lesions from 52 CEUS video sequences (30 benign and 22 malignant). Lesion detection involves wavelet transform zero crossings utilization as an initialization step to the Markov random field model toward the lesion contour extraction. After FLL detection across frames, time intensity curve (TIC) is computed which provides the contrast agents' behavior at all vascular phases with respect to adjacent parenchyma for each patient. From each TIC, eight features were automatically calculated and employed into the support vector machines (SVMs) classification algorithm in the design of the image analysis model. Results: With regard to FLLs detection accuracy, all lesions detected had an average overlap value of 0.89+/-0.16 with manual segmentations for all CEUS frame-subsets included in the study. Highest classification accuracy from the SVM model was 90.3%, misdiagnosing three benign and two malignant FLLs with sensitivity and specificity values of 93.1% and 86.9%, respectively. Conclusions: The proposed quantification system that employs FLLs detection and classification algorithms may be of value to physicians as a second opinion tool for avoiding unnecessary invasive procedures. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:3948 / 3959
页数:12
相关论文
共 27 条
  • [1] Differentiation of Focal Liver Lesions: Usefulness of Parametric Imaging with Contrast-enhanced US
    Anaye, Anass
    Perrenoud, Genevieve
    Rognin, Nicolas
    Arditi, Marcel
    Mercier, Laurent
    Frinking, Peter
    Ruffieux, Christiane
    Peetrons, Philippe
    Meuli, Reto
    Meuwly, Jean-Yves
    [J]. RADIOLOGY, 2011, 261 (01) : 300 - 310
  • [2] Interactive visual analysis of contrast-enhanced ultrasound data based on small neighborhood statistics
    Angelelli, Paolo
    Nylund, Kim
    Gilja, Odd Helge
    Hauser, Helwig
    [J]. COMPUTERS & GRAPHICS-UK, 2011, 35 (02): : 218 - 226
  • [3] [Anonymous], 2008, A Wavelet Tour of Signal Processing: The Sparse Way
  • [4] Unclear Focal Liver Lesions in Contrast-Enhanced Ultrasonography - Lessons to be Learned from the DEGUM Multicenter Study for the Characterization of Liver Tumors
    Bernatik, T.
    Seitz, K.
    Blank, W.
    Schuler, A.
    Dietrich, C. F.
    Strobel, D.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2010, 31 (06): : 577 - 581
  • [5] BESAG J, 1974, J ROY STAT SOC B MET, V36, P192
  • [6] Brinks R, 2008, COMPUT APPL MATH, V27, P79
  • [7] Management of Hepatocellular Carcinoma: An Update
    Bruix, Jordi
    Sherman, Morris
    [J]. HEPATOLOGY, 2011, 53 (03) : 1020 - 1022
  • [8] Practical selection of SVM parameters and noise estimation for SVM regression
    Cherkassky, V
    Ma, YQ
    [J]. NEURAL NETWORKS, 2004, 17 (01) : 113 - 126
  • [9] Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) -: Update 2008
    Claudon, M.
    Cosgrove, D.
    Albrecht, T.
    Bolondi, L.
    Bosio, M.
    Calliada, F.
    Correas, J. -M.
    Darge, K.
    Dietrich, C.
    D'Onofrio, M.
    Evans, D. H.
    Filice, C.
    Greiner, L.
    Jaeger, K.
    de Jong, N.
    Leen, E.
    Lencioni, R.
    Lindsell, D.
    Martegani, A.
    Meairs, S.
    Nolsoe, C.
    Piscaglia, F.
    Ricci, P.
    Seidel, G.
    Skjoldbye, B.
    Solbiati, L.
    Thorelius, L.
    Tranquart, F.
    Weskott, H. P.
    Whittingham, T.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2008, 29 (01): : 28 - 44
  • [10] GUIDELINES AND GOOD CLINICAL PRACTICE RECOMMENDATIONS FOR CONTRAST ENHANCED ULTRASOUND (CEUS) IN THE LIVER - UPDATE 2012 A WFUMB-EFSUMB INITIATIVE IN COOPERATION WITH REPRESENTATIVES OF AFSUMB, AIUM, ASUM, FLAUS AND ICUS
    Claudon, Michel
    Dietrich, Christoph F.
    Choi, Byung Ihn
    Cosgrove, David O.
    Kudo, Masatoshi
    Nolsoe, Christian P.
    Piscaglia, Fabio
    Wilson, Stephanie R.
    Barr, Richard G.
    Chammas, Maria C.
    Chaubal, Nitin G.
    Chen, Min-Hua
    Clevert, Dirk Andre
    Correas, Jean Michel
    Ding, Hong
    Forsberg, Flemming
    Fowlkes, J. Brian
    Gibson, Robert N.
    Goldberg, Barry B.
    Lassau, Nathalie
    Leen, Edward L. S.
    Mattrey, Robert F.
    Moriyasu, Fuminori
    Solbiati, Luigi
    Weskott, Hans-Peter
    Xu, Hui-Xiong
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (02) : 187 - 210