Capillary electrophoresis and phenylboronic acid solid phase extraction for the determination of S-adenosylmethionine/S-adenosylhomocysteine ratio in human urine

被引:10
|
作者
Ivanov, Alexander Vladimirovich [1 ]
Virus, Edward Danielevich [1 ]
Nikiforova, Ksenya Alexandrovna [1 ]
Kushlinskii, Nicolai Evgenevich [2 ]
Luzyanin, Boris Petrovich [1 ]
Maksimova, Marina Yurievna [3 ]
Piradov, Mikhail Aleksanrovich [3 ]
Kubatiev, Aslan Amirkhanovich [1 ]
机构
[1] Fed State Budgetary Sci Inst, Inst Gen Pathol & Pathophysiol, Moscow 125315, Russia
[2] NN Blokhin Russian Canc Res Ctr, Moscow, Russia
[3] Res Ctr Neurol, Moscow, Russia
基金
俄罗斯科学基金会;
关键词
Capillary electrophoresis; S-adenosylhomocysteine; S-adenosylmethionine; Urine; LC-MS/MS; HOMOCYSTEINE; BIOMARKERS; QUANTIFICATION; INDICATOR; ADENOSINE; DISEASE;
D O I
10.1002/elps.201600242
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An approach that allows direct analysis of the ratio of S-adenosylmethionine (SAM) and S-adenosylhomocysteine (SAH) by using CE is presented. The analytes were extracted on phenylboronic acid phase and eluted with 100 mmol/L HCl. CE separation of the analytes took place in the transient isotachophoresis mode with addition of NaCl and meglumine to the samples. The sensitivity (S/N = 3) and quantification limit (S/N = 10) of the method were 0.07 and 0.2 mu mol/L, respectively, using a silica capillary with 50 mu m internal diameter and 30.5 cm total length. The BGE was 0.02 mol/L Tris with 1 mol/L HCOOH (pH 2.2), and the separation voltage was 15-17 kV. Accuracy of SAM and SAH analysis in urine was 96 and 105%, respectively; interday precision for the SAM/SAH ratio was within 6%. The theoretical plate number exceeded a million. Total analysis time was 8.5 min.
引用
收藏
页码:2663 / 2669
页数:7
相关论文
共 50 条
  • [1] Simultaneous determination of S-adenosylmethionine and S-adenosylhomocysteine by capillary zone electrophoresis
    Panak, KC
    Giorgieri, SA
    Diaz, LE
    Ruiz, OA
    ELECTROPHORESIS, 1997, 18 (11) : 2047 - 2049
  • [2] Low S-adenosylmethionine/S-adenosylhomocysteine Ratio in Urine is Associated with Chronic Kidney Disease
    Kruglova, Maria Petrovna
    Grachev, Sergej Vital'evich
    Bulgakova, Polina Olegovna
    Ivanov, Alexander Vladimirovich
    Virus, Edward Danielevich
    Nikiforova, Ksenya Alexandrovna
    Fedoseev, Anatolij Nikolaevich
    Savina, Galina Dmitrievna
    Kubatiev, Aslan Amirkhanovich
    LABORATORY MEDICINE, 2020, 51 (01) : 80 - 85
  • [3] S-Adenosylhomocysteine Assay in the Urine by Capillary Electrophoresis
    Luzyanin, B. P.
    Ivanov, A. V.
    Viryus, E. D.
    Kubatiev, A. A.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2015, 159 (04) : 524 - 527
  • [4] Determination of S-Adenosylmethionine and S-Adenosylhomocysteine in Human Urine by Ion Chromatography with Solid Phase Extraction Based on the Application of Micromolecule Ion-Pairing Agent
    Zhai Yijing
    Wang Wei
    Luo Bin
    Xie Ying
    Du Hongzhen
    Wang Dandan
    Zhao Xiaopeng
    Kang Weijun
    Shi Hongmei
    Li Zengning
    ANALYTICAL LETTERS, 2020, 53 (18) : 2886 - 2902
  • [5] Simultaneous detection of S-adenosylmethionine and S-adenosylhomocysteine in mouse and rat tissues by capillary electrophoresis
    Uthus, EO
    ELECTROPHORESIS, 2003, 24 (7-8) : 1221 - 1226
  • [6] S-Adenosylhomocysteine Assay in the Urine by Capillary Electrophoresis
    B. P. Luzyanin
    A. V. Ivanov
    E. D. Viryus
    A. A. Kubatiev
    Bulletin of Experimental Biology and Medicine, 2015, 159 : 524 - 527
  • [7] Determination of S-adenosylmethionine and S-adenosylhomocysteine in blood plasma by UPLC with fluorescence detection
    Ivanov, Alexander Vladimirovich
    Dubchenko, Ekaterina Alexandrovna
    Kruglova, Maria Petrovna
    Virus, Edward Danielevich
    Bulgakova, Polina Olegovna
    Alexandrin, Valery Vasil'evich
    Fedoseev, Anatolij Nikolaevich
    Boyko, Alexey Nikolaevich
    Grachev, Sergej Vitalievich
    Kubatiev, Aslan Amirkhanovich
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1124 : 366 - 374
  • [8] Validated HPLC-Fl Method for the Analysis of S-Adenosylmethionine and S-Adenosylhomocysteine Biomarkers in Human Blood
    Albu, Camelia
    Litescu, Simona Carmen
    Radu, Gabriel Lucian
    Aboul-Enein, Hassan Y.
    JOURNAL OF FLUORESCENCE, 2013, 23 (03) : 381 - 386
  • [9] Determination of S-adenosylmethionine, S-adenosylhomocysteine, and methylthioadenosine in urine using solvent-modified micellar electrokinetic chromatography
    Ivanov, Alexander Vladimirovich
    Kruglova, Mariya Petrovna
    Virus, Edward Danielevich
    Bulgakova, Polina Olegovna
    Vital'evich Grachev, Sergei
    Kubatiev, Aslan Amirkhanovich
    ELECTROPHORESIS, 2020, 41 (3-4) : 209 - 214
  • [10] S-adenosylhomocysteine and the ratio of S-adenosylmethionine to S-adenosylhomocysteine are not related to folate, cobalamin and vitamin B6 concentrations
    Becker, A
    Smulders, YM
    Teerlink, T
    Struys, EA
    de Meer, K
    Kostense, PJ
    Jakobs, C
    Dekker, JM
    Nijpels, G
    Heine, RJ
    Bouter, LM
    Stehouwer, CDA
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2003, 33 (01) : 17 - 25