Regional deconvolution method for partial volume correction in brain PET

被引:0
|
作者
Rusinek, H [1 ]
Tsuia, WH [1 ]
de Leon, MJ [1 ]
机构
[1] Bellevue Hosp Ctr, Dept Radiol, New York, NY 10016 USA
关键词
functional imaging; brain metabolism; MRI; PET; partial volume correction;
D O I
10.1117/12.428166
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Correction of PET images for partial volume effects (PVE) is of particular utility in studies of metabolism in brain aging and brain disorders, PVE is commonly corrected using voxel-by-voxel factors obtained from a high resolution brain mask (obtained from the coregistered MR scan), after convolution with the point spread function (PSF) of the imaging system. In a recently proposed regional deconvolution (RD) method, the observed regional activity is expressed as linear combinations of the true metabolic activity. The weights are obtained by integrating the PSF over the geometric extent of the brain regions. We have analyzed the accuracy of RD and two other PVE correction algorithms under a variety of conditions using simulated PET scans. Each of the brain regions was assigned a distribution of metabolic activity, with gray matter/white matter contrast representative of subjects in several age categories. Simulations were performed over a wide range of PET resolutions. The influence of PET/MR misregistration and heterogeneity of brain metabolism were also evaluated. Our results demonstrate the importance of correcting PET metabolic images for PVE. Without such correction, the regional brain activity values are contaminated with 30-40% errors. Under most conditions studied, the accuracy of RD and of the three-compartmental method were superior to the accuracy of the two-compartmental method. Our study provides the first demonstration of the feasibility of RD algorithm to provide accurate correction for a large number (n=109) of brain compartments. PVE correction methods appear to be promising tools in studies of metabolism in normal brain, brain aging, and brain disorders.
引用
收藏
页码:409 / 418
页数:10
相关论文
共 50 条
  • [31] Objective evaluation of voxelwise partial volume correction methods in brain PET imaging
    Bilgel, Murat
    Zhu, Yansong
    Rousset, Olivier
    Wong, Dean
    Resnick, Susan
    Rahmim, Arman
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [32] Diffpvc: A Conditional Diffusion Model for Partial Volume Correction in Brain PET Imaging
    Sun, Y.
    Mawlawi, O. R.
    MEDICAL PHYSICS, 2024, 51 (10) : 7894 - 7894
  • [33] MRI-guided brain PET image filtering and partial volume correction
    Yan, Jianhua
    Lim, Jason Chu-Shern
    Townsend, David W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 961 - 976
  • [34] Validations for MR-based partial volume correction for brain PET imaging
    Matsubara, Keisuke
    Ibaraki, Masanobu
    Maeda, Tetsuya
    Kinoshita, Toshibumi
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [35] Functional and structural synergy for resolution recovery and partial volume correction in brain PET
    Shidahara, Miho
    Tsoumpas, Charalampos
    Hammers, Alexander
    Boussion, Nicolas
    Visvikis, Dimitris
    Suhara, Tetsuya
    Kanno, Iwao
    Turkheimer, Federico E.
    NEUROIMAGE, 2009, 44 (02) : 340 - 348
  • [36] Functional and structural synergy for resolution recovery and partial volume correction in brain pet
    Shidahara, M.
    Tsoumpas, C.
    Hammers, A.
    Boussion, N.
    Visvikis, D.
    Ito, H.
    Kimura, Y.
    Suhara, T.
    Kanno, I.
    Turkheimer, F.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 : S73 - S74
  • [37] Accuracy of the Mueller-Gaertner partial volume correction in brain PET.
    Fahey, FH
    Gage, HD
    Harkness, BA
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1017 - 1017
  • [38] An Investigation of Partial Volume Effect and Partial Volume Correction in Small Animal Positron Emission Tomography (PET) of the Rat Brain
    Lehnert, Wencke
    Gregoire, Marie-Claude
    Hu, Xiao
    Meikle, Steven R.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4485 - +
  • [39] PET quantification: Strategies for partial volume correction
    Bettinardi V.
    Castiglioni I.
    De Bernardi E.
    Gilardi M.C.
    Clinical and Translational Imaging, 2014, 2 (3) : 199 - 218
  • [40] An improved method for voxel-based partial volume correction in PET and SPECT
    Erlandsson, Kjell
    Wong, A. T.
    van Heertum, R.
    Mann, J. J.
    Parsey, R. V.
    NEUROIMAGE, 2006, 31 : T84 - T84