Regional deconvolution method for partial volume correction in brain PET

被引:0
|
作者
Rusinek, H [1 ]
Tsuia, WH [1 ]
de Leon, MJ [1 ]
机构
[1] Bellevue Hosp Ctr, Dept Radiol, New York, NY 10016 USA
关键词
functional imaging; brain metabolism; MRI; PET; partial volume correction;
D O I
10.1117/12.428166
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Correction of PET images for partial volume effects (PVE) is of particular utility in studies of metabolism in brain aging and brain disorders, PVE is commonly corrected using voxel-by-voxel factors obtained from a high resolution brain mask (obtained from the coregistered MR scan), after convolution with the point spread function (PSF) of the imaging system. In a recently proposed regional deconvolution (RD) method, the observed regional activity is expressed as linear combinations of the true metabolic activity. The weights are obtained by integrating the PSF over the geometric extent of the brain regions. We have analyzed the accuracy of RD and two other PVE correction algorithms under a variety of conditions using simulated PET scans. Each of the brain regions was assigned a distribution of metabolic activity, with gray matter/white matter contrast representative of subjects in several age categories. Simulations were performed over a wide range of PET resolutions. The influence of PET/MR misregistration and heterogeneity of brain metabolism were also evaluated. Our results demonstrate the importance of correcting PET metabolic images for PVE. Without such correction, the regional brain activity values are contaminated with 30-40% errors. Under most conditions studied, the accuracy of RD and of the three-compartmental method were superior to the accuracy of the two-compartmental method. Our study provides the first demonstration of the feasibility of RD algorithm to provide accurate correction for a large number (n=109) of brain compartments. PVE correction methods appear to be promising tools in studies of metabolism in normal brain, brain aging, and brain disorders.
引用
收藏
页码:409 / 418
页数:10
相关论文
共 50 条
  • [21] Investigation of partial volume correction methods for brain FDG PET studies
    Yang, J
    Huang, SC
    Mega, M
    Lin, KP
    Toga, AW
    Small, GW
    Phelps, ME
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3322 - 3327
  • [22] A Comparison of the Options for Brain Partial Volume Correction Using PET/MRI
    Thomas, Benjamin A.
    Erlandsson, Kjell
    Reilhac, Anthonin
    Bousse, Alexandre
    Kazantsev, Daniil
    Pedemonte, Stefano
    Vunckx, Kathleen
    Arridge, Simon
    Ourselin, Sebastien
    Hutton, Brian F.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2902 - 2906
  • [23] Deconvolution-based partial volume correction in Raclopride-PET and Monte Carlo comparison to MR-based method
    Tohka, Jussi
    Reilhac, Anthonin
    NEUROIMAGE, 2008, 39 (04) : 1570 - 1584
  • [24] Partial Volume Correction Strategies in PET
    Rousset, Olivier
    Rahmim, Arman
    Alavi, Abass
    Zaidi, Habib
    PET CLINICS, 2007, 2 (02) : 235 - 249
  • [25] MRI-based partial volume correction method for brain FDG-PET images.
    Yang, J
    Huang, SC
    Small, GW
    Phelps, ME
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 161 - 161
  • [26] Comparison of PET reconstruction resolution recovery and post-reconstruction deconvolution for partial volume effect correction (PVC) in PET
    Le Pogam, Adrien
    Alessio, Adam
    Kandel, Benjamin
    Kirov, Assen
    Barret, Olivier
    Fernandez, Philippe
    Le Rest, Catherine Cheze
    Visvikis, Dimitris
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [27] A method for model-free partial volume correction in oncological PET
    Frank Hofheinz
    Jens Langner
    Jan Petr
    Bettina Beuthien-Baumann
    Liane Oehme
    Jörg Steinbach
    Jörg Kotzerke
    Jörg van den Hoff
    EJNMMI Research, 2
  • [28] A method for model-free partial volume correction in oncological PET
    Hofheinz, Frank
    Langner, Jens
    Petr, Jan
    Beuthien-Baumann, Bettina
    Oehme, Liane
    Steinbach, Joerg
    Kotzerke, Joerg
    van den Hoff, Joerg
    EJNMMI RESEARCH, 2012, 2
  • [29] A Partial Volume Correction Method Based on Deep Image Prior Using Blind Deconvolution
    Liu, Zheng
    Gao, Yuanyuan
    Fu, Rong
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [30] Investigation of partial volume correction methods for brain FDG-PET studies
    Yang, J
    Mega, M
    Huang, SC
    Lin, KP
    Toga, A
    Small, G
    Phelps, ME
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1670 - 1674