Regional deconvolution method for partial volume correction in brain PET

被引:0
作者
Rusinek, H [1 ]
Tsuia, WH [1 ]
de Leon, MJ [1 ]
机构
[1] Bellevue Hosp Ctr, Dept Radiol, New York, NY 10016 USA
来源
MEDICAL IMAGING 2001: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES | 2001年 / 4321卷
关键词
functional imaging; brain metabolism; MRI; PET; partial volume correction;
D O I
10.1117/12.428166
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Correction of PET images for partial volume effects (PVE) is of particular utility in studies of metabolism in brain aging and brain disorders, PVE is commonly corrected using voxel-by-voxel factors obtained from a high resolution brain mask (obtained from the coregistered MR scan), after convolution with the point spread function (PSF) of the imaging system. In a recently proposed regional deconvolution (RD) method, the observed regional activity is expressed as linear combinations of the true metabolic activity. The weights are obtained by integrating the PSF over the geometric extent of the brain regions. We have analyzed the accuracy of RD and two other PVE correction algorithms under a variety of conditions using simulated PET scans. Each of the brain regions was assigned a distribution of metabolic activity, with gray matter/white matter contrast representative of subjects in several age categories. Simulations were performed over a wide range of PET resolutions. The influence of PET/MR misregistration and heterogeneity of brain metabolism were also evaluated. Our results demonstrate the importance of correcting PET metabolic images for PVE. Without such correction, the regional brain activity values are contaminated with 30-40% errors. Under most conditions studied, the accuracy of RD and of the three-compartmental method were superior to the accuracy of the two-compartmental method. Our study provides the first demonstration of the feasibility of RD algorithm to provide accurate correction for a large number (n=109) of brain compartments. PVE correction methods appear to be promising tools in studies of metabolism in normal brain, brain aging, and brain disorders.
引用
收藏
页码:409 / 418
页数:10
相关论文
共 18 条
  • [1] [Anonymous], 1992, ART SCI COMPUTING
  • [2] CONDON B, 1986, LANCET, V1, P1355
  • [3] QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .6. EFFECT OF NONUNIFORM RESOLUTION
    HOFFMAN, EJ
    HUANG, SC
    PLUMMER, D
    PHELPS, ME
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (05) : 987 - 999
  • [4] QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE
    HOFFMAN, EJ
    HUANG, SC
    PHELPS, ME
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) : 299 - 308
  • [5] ANALYSIS OF EMISSION TOMOGRAPHIC SCAN DATA - LIMITATIONS IMPOSED BY RESOLUTION AND BACKGROUND
    KESSLER, RM
    ELLIS, JR
    EDEN, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (03) : 514 - 522
  • [6] Influence of spatially heterogeneous background activity on ''hot object'' quantitation in brain emission computed tomography
    Links, JM
    Zubieta, JK
    Meltzer, CC
    Stumpf, MJ
    Frost, JJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (04) : 680 - 687
  • [7] DECREASES IN REGIONAL CEREBRAL BLOOD-FLOW WITH NORMAL AGING
    MARTIN, AJ
    FRISTON, KJ
    COLEBATCH, JG
    FRACKOWIAK, RSJ
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (04) : 684 - 689
  • [8] CORRECTION OF PET DATA FOR PARTIAL VOLUME EFFECTS IN HUMAN CEREBRAL-CORTEX BY MR IMAGING
    MELTZER, CC
    LEAL, JP
    MAYBERG, HS
    WAGNER, HN
    FROST, JJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) : 561 - 570
  • [9] Meltzer CC, 1999, J NUCL MED, V40, P2053
  • [10] MEASUREMENT OF RADIOTRACER CONCENTRATION IN BRAIN GRAY-MATTER USING POSITRON EMISSION TOMOGRAPHY - MRI-BASED CORRECTION FOR PARTIAL VOLUME EFFECTS
    MULLERGARTNER, HW
    LINKS, JM
    PRINCE, JL
    BRYAN, RN
    MCVEIGH, E
    LEAL, JP
    DAVATZIKOS, C
    FROST, JJ
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1992, 12 (04) : 571 - 583