Analysis on thermodynamic and economic performances of supercritical carbon dioxide Brayton cycle with the dynamic component models and constraint conditions

被引:18
作者
Liu, Zhiyuan [1 ,2 ]
Wang, Peng [3 ]
Sun, Xiangyu [4 ]
Zhao, Ben [3 ,4 ]
机构
[1] Dongguan Univ Technol, Sch Chem Engn & Energy Technol, Dongguan 523808, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
[3] North China Elect Power Univ, Sch Energy Power & Mech Engn, Beijing 102206, Peoples R China
[4] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
Supercritical CO2; Brayton cycle; Thermo-economic performance; Dynamic component models; HEAT-EXCHANGERS; POWER CYCLE; EXERGY ANALYSIS; CO2; ENERGY; OPTIMIZATION; INTEGRATION; WORKING; SODIUM; ZIGZAG;
D O I
10.1016/j.energy.2021.122792
中图分类号
O414.1 [热力学];
学科分类号
摘要
Turbomachinery and heat exchanger are key components of the supercritical carbon dioxide (CO2) Brayton cycle system. It is of great necessity to investigate realistic cycle performance coupled with components characteristics. This paper analyzes the efficiency and economy of supercritical CO2 Brayton cycle based on the dynamic component models and constraint conditions. The parametric limits are compressor inlet temperature range from 305 K to 310 K, inlet pressure range from 7.4 MPa to 8.3 MPa, and maximum cycle pressure range from 15 MPa to 30 MPa. The results reveal that the achievable efficiency of a simple cycle is 0.13-0.62% points lower than theoretical maximum efficiency after considering constraint conditions. Meanwhile, the levelized cost of electricity (LCOE) under constraint conditions is 0.00038-0.00085$/(kW center dot h) higher than the theoretical minimum LCOE. For a recompression cycle, constraint conditions have a more significant impact. The achievable efficiency of the cycle is 0.81-1.21% points lower than the maximum efficiency because of the constraints, and the available LCOE under constraint conditions is 0.0012-0.0018$/(kW.h) higher than the theoretical minimum LCOE. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:19
相关论文
共 79 条
  • [31] Feher E. G., 1968, Energy Conversion, V8, P85, DOI 10.1016/0013-7480(68)90105-8
  • [32] Fottner Leonh, 1990, AGARD ADVISORY REPOR
  • [33] Comparative energy and exergy analysis and optimisation study on the supercritical CO2recompression power cycle
    Gumus, Emrah
    Bashan, Veysi
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2020, 32 (02) : 130 - 149
  • [34] Thermodynamic study of supercritical CO2 Brayton cycle using an isothermal compressor
    Heo, Jin Young
    Kim, Min Seok
    Baik, Seungjoon
    Bae, Seong Jun
    Lee, Jeong Ik
    [J]. APPLIED ENERGY, 2017, 206 : 1118 - 1130
  • [35] Hesselgreaves J.E., 2016, COMPACT HEAT EXCHANG
  • [36] Ho C K., 2015, P ASME 2015 9 INT C, DOI DOI 10.1115/ES2015-49467
  • [37] Jansen W., 1967, Royal Society Conference on Internal Aerodynamics Turbomachinery, P133
  • [38] LOSSES IN VANELESS DIFFUSERS OF CENTRIFUGAL COMPRESSORS AND PUMPS - ANALYSIS EXPERIMENT AND DESIGN
    JOHNSTON, JP
    DEAN, RC
    [J]. JOURNAL OF ENGINEERING FOR POWER, 1966, 88 (01): : 49 - &
  • [39] A MEAN LINE PREDICTION METHOD FOR AXIAL-FLOW TURBINE EFFICIENCY
    KACKER, SC
    OKAPUU, U
    [J]. JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1982, 104 (01): : 111 - 119
  • [40] Medium temperature carbon dioxide gas turbine reactor
    Kato, Y
    Nitawaki, T
    Muto, Y
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2004, 230 (1-3) : 195 - 207