Morphological assessment of in vivo wear of orthopaedic implants using multiscalar wavelets

被引:12
作者
Jiang, XQ [1 ]
Blunt, L [1 ]
机构
[1] Univ Huddersfield, Sch Engn, Ctr Precis Technol, Huddersfield HD1 3DH, W Yorkshire, England
关键词
morphological features; multiscalar wavelet; morphological assessment; surfaces of orthopaedic implant;
D O I
10.1016/S0043-1648(01)00644-5
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The properties of the femoral counterface are recognised as very significant in the study of the tribological design of artificial joints and the wear of ultra-high molecular polyethylene (UHMWPE). Research has shown that morphological features of femoral counterfaces heavily interfere with the wear of UHMWPE. It has been reported that if 1-2 mum defects or deep scratches are presented in a diamond like carbon (DLC.) coated head, the third-body damage can cause a 7-15-fold increase in a UHMWPE wear rate, and in a metallic surface. The typical third-body damage can be up to a 30-70-fold compared with smooth roughness surface. Therefore, the identification of morphology of counterface surfaces has become an important requirement in the field of wear and tribology of the hip joint system. This paper proposes a methodology for a multiscalar wavelet for addressing morphological surfaces in order to extract the significant elements of 3D bearing surfaces of orthopaedic implants. The multiscalar wavelet is used to decompose a surface signal into the scalar domain. In wavelet analysis, the Cartesian space-based information is transferred into scale-based information, which provides not only the frequency events of the original signal but also keeps their location properties; as a result, morphological features can be identified. A series of ceramic, metallic and DLC femoral heads in vivo wear have been used to demonstrate the applicability of using the multiscalar wavelet model in the assessment of the morphology of these surfaces. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 8 条
[1]  
[Anonymous], 2000, P R SOC LOND A
[2]   THE INFLUENCE OF CONTACT STRESS ON THE WEAR OF UHMWPE FOR TOTAL REPLACEMENT HIP PROSTHESES [J].
BARBOUR, PSM ;
BARTON, DC ;
FISHER, J .
WEAR, 1995, 181 :250-257
[3]  
Blunt L., 1998, DEV BASIS 3D SURFACE
[4]  
Daubechies I., 1993, Ten Lectures of Wavelets, V28, P350
[5]   Wear of ultra-high molecular weight polyethylene against damaged and undamaged stainless steel and diamond-like carbon-coated counterfaces [J].
Firkins, P ;
Hailey, JL ;
Fisher, J ;
Lettington, AH ;
Butter, R .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (10) :597-601
[6]  
Fisher J, 1995, Proc Inst Mech Eng H, V209, P263, DOI 10.1243/PIME_PROC_1995_209_353_02
[7]  
*ISO, 1996, 135653 ISO 3
[8]   Three-dimensional surface characterization for orthopaedic joint prostheses [J].
Jiang, XQ ;
Blunt, L ;
Stout, KJ .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H1) :49-68