Modelling energy use in residential buildings: How design decisions influence final energy performance in various Chilean climates

被引:21
作者
Simon, Francois [1 ]
Ordonez, Javier [1 ]
Girard, Aymeric [2 ]
Parrado, Cristobal [1 ]
机构
[1] Univ Granada, ETS Ingn Caminos Canales & Puertos, Dept Civil Engn, Granada, Spain
[2] Univ Adolfo IbAnez, Fac Ingn Ciencias, Vina Del Mar, Chile
关键词
Energy modelling; Building thermal performance; Parametric sensitivity analysis; Energy efficiency; CO2; emissions; Chile; HOURLY COOLING LOAD; REGRESSION-MODELS; OFFICE BUILDINGS; SOLAR-RADIATION; SIMULATION; CONSUMPTION; INSULATION; OPTIMIZATION; REQUIREMENTS; VENTILATION;
D O I
10.1177/1420326X18792661
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To reduce the energy consumption in buildings, there is a demand for tools that identify significant parameters of energy performance. The work presents the development and validation of a simulation model, called MEEDI, and graphical figures for the parametric sensitivity investigation of energy performance in different climates in Chile. The MEEDI is based on the ISO 13790 monthly calculation method of building energy use with two improved procedures for the calculation of the heat transfer through the floor and the solar heat gains. The graphical figures illustrate the effects of climate conditions, envelope components and window size and orientation on the energy consumption. The MEEDI program can contribute to find the best solution to increase energy efficiency in residential buildings. It can be adapted for various parameters, making it useful for future projects. The economic viability of specific measures for building envelope materials was analysed. Payback periods range from 5 to 27 years depending on the location and energy scenario. The study illustrates how building design decisions can have a significant impact on final energy performance. With simple envelope components modification, valuable energy gains and carbon emission reductions can be achieved in a cost-effective manner in Chile.
引用
收藏
页码:533 / 551
页数:19
相关论文
共 96 条
[1]   Simulation of energy consumption for Kuwaiti domestic buildings [J].
Al-ajmi, Faaaj F. ;
Hanby, V. I. .
ENERGY AND BUILDINGS, 2008, 40 (06) :1101-1109
[2]   Computer-aided building energy analysis techniques [J].
Al-Homoud, MS .
BUILDING AND ENVIRONMENT, 2001, 36 (04) :421-433
[3]   Utilizing transfer function method for hourly cooling load calculations [J].
AlRabghi, OMA ;
AlJohani, KM .
ENERGY CONVERSION AND MANAGEMENT, 1997, 38 (04) :319-332
[4]  
[Anonymous], 2007, 133702007 ISO
[5]  
[Anonymous], 2015, CO2 EM FUEL COMB
[6]  
[Anonymous], 2007, 69462007 ISO BRIT ST
[7]  
[Anonymous], 2017, METEONORM VERSION 7
[8]  
[Anonymous], 2005, P BS2005 9 C INT BUI
[9]  
ASHRAE, 2013, ASHRAE HDB FUND EN E
[10]  
ASHRAE, 2013, ASHRAE HDB FUND CLIM