Powerline interference suppression in high-resolution ECG

被引:13
作者
Bazhyna, A [1 ]
Christov, II [1 ]
Gotchev, A [1 ]
Daskalov, IK [1 ]
Egiazarian, K [1 ]
机构
[1] Tampere Univ Technol, Inst Signal Proc, Tampere, Finland
来源
COMPUTERS IN CARDIOLOGY 2003, VOL 30 | 2003年 / 30卷
关键词
D O I
10.1109/CIC.2003.1291217
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The efficacy of four powerline interference suppression methods was tested for application in high-resolution electrocardiogram (ECG). The goal was minimal distortion of the original signal micro-potential waveform, combined with maximum noise reduction. Simulated low amplitude His-bundle potentials were used for the evaluation. Several objective parameters were measured, such as mean square error and mean absolute error. The methods were applied for His-bundle potentials recovery from real surface ECG signals. Synchronous intracardiac signals with well expressed His potential were recorded and used for reference. Modified time-domain subtraction and regression subtraction methods were found superior to notch filters and spectral interpolation.
引用
收藏
页码:561 / 564
页数:4
相关论文
共 10 条
[1]   Methods to reduce the variability of EMG power spectrum estimates [J].
Baratta, RV ;
Solomonow, M ;
Zhou, BH ;
Zhu, M .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (05) :279-285
[2]   NEW APPROACH TO THE DIGITAL ELIMINATION OF 50 HZ INTERFERENCE FROM THE ELECTROCARDIOGRAM [J].
CHRISTOV, II ;
DOTSINSKY, IA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (04) :431-434
[3]   Dynamic powerline interference subtraction from biosignals [J].
Christov, II .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2000, 24 (04) :169-172
[4]  
COLEMAN TF, 1988, FRONTIERS APPL MATH, V4
[5]   Accuracy of 50 Hz interference subtraction from an electrocardiogram [J].
Dotsinsky, IA ;
Daskalov, IK .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (06) :489-494
[6]   FAST AND RELIABLE QRS ALIGNMENT TECHNIQUE FOR HIGH-FREQUENCY ANALYSIS OF SIGNAL-AVERAGED ECG [J].
ESCALONA, OJ ;
MITCHELL, RH ;
BALDERSON, DE ;
HARRON, DWG .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 :S137-S146
[7]   SURFACE RECORDING OF HIS-PURKINJE ACTIVITY ON AN EVERY-BEAT BASIS WITHOUT DIGITAL AVERAGING [J].
FLOWERS, NC ;
SHVARTSMAN, V ;
KENNELLY, BM ;
SOHI, GS ;
HORAN, LG .
CIRCULATION, 1981, 63 (04) :948-952
[8]   SUBTRACTION OF 50 HZ INTERFERENCE FROM THE ELECTROCARDIOGRAM [J].
LEVKOV, C ;
MICHOV, G ;
IVANOV, R ;
DASKALOV, IK .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (04) :371-373
[9]  
Mewett DT, 2001, P ANN INT IEEE EMBS, V23, P2190, DOI 10.1109/IEMBS.2001.1017205
[10]   Noise coherence in closely-spaced electrodes: The implications for spatial averaged ECG recordings [J].
Turner, IN ;
Wang, W ;
English, MJ ;
Vincent, R .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1995, 19 (05) :158-161