Quantitation of malondialdehyde in gingival crevicular fluid by a high-performance liquid chromatography-based method

被引:37
作者
Bastos, Alliny Souza [1 ]
de Melo Loureiro, Ana Paula [2 ]
de Oliveira, Tiago Franco [2 ]
Tfaile Corbi, Samia Cruz [1 ]
Scarel Caminaga, Raquel Mantuaneli [3 ]
Rossa Junior, Carlos [1 ]
Orrico, Silvana R. P. [1 ]
机构
[1] Univ Estadual Paulista UNESP, Araraquara Sch Dent, Dept Diag & Surg, BR-14801903 Sao Paulo, Brazil
[2] Univ Sao Paulo, Fac Pharmaceut Sci, Dept Clin & Toxicol Anal, BR-05508900 Sao Paulo, Brazil
[3] Univ Estadual Paulista UNESP, Araraquara Sch Dent, Dept Morphol, BR-14801903 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Lipid peroxidation; Malondialdehyde; Periodontal diseases; Gingival crevicular fluid; HPLC; LIPID-PEROXIDATION LEVELS; TOTAL OXIDANT STATUS; OXIDATIVE STRESS; CHRONIC PERIODONTITIS; PLASMA; DISEASE; SALIVA; SERUM; COMPLICATIONS; MALONALDEHYDE;
D O I
10.1016/j.ab.2012.01.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Lipid peroxidation (LPO) has been associated with periodontal disease, and the evaluation of malondialdehyde (MDA) in the gingival crevicular fluid (GCF), an inflammatory exudate from the surrounding tissue of the periodontium, may be useful to clarify the role of LPO in the pathogenesis of periodontal disease. We describe the validation of a method to measure MDA in the GCF using high-performance liquid chromatography. MDA calibration curves were prepared with phosphate-buffered solution spiked with increasing known concentrations of MDA. Healthy and diseased GCF samples were collected from the same patient to avoid interindividual variability. MDA response was linear in the range measured, and excellent agreement was observed between added and detected concentrations of MDA. Samples' intra- and interday coefficients of variation were below 6.3% and 12.4%, respectively. The limit of quantitation (signal/noise = 5) was 0.03 mu M. When the validated method was applied to the GCF, excellent agreement was observed in the MDA quantitation from healthy and diseased sites, and diseased sites presented more MDA than healthy sites (P < 0.05). In this study, a validated method for MDA quantitation in GCF was established with satisfactory sensitivity, precision, and accuracy. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [31] Chiral separation and quantitation of dorzolamide hydrochloride enantiomers by high-performance liquid chromatography
    Shamsipur, Mojtaba
    Heydari, Rouhollah
    Jamasbi, Elahe Sadat
    Abdollahpour, Assem
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (15) : 2328 - 2333
  • [32] Simultaneous determination of malondialdehyde and ofloxacin in plasma using an isocratic high-performance liquid chromatography/fluorescence detection system
    Cheng, Guan-Wen
    Wu, Hsin-Lung
    Huang, Yeou-Lih
    ANALYTICA CHIMICA ACTA, 2008, 616 (02) : 230 - 234
  • [33] High-Performance Liquid Chromatography Method for Determination of Diltiazem in Human Plasma
    Baviskar, Dheeraj
    Sharma, Rajesh
    Jain, Dinesh
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (07) : 5048 - 5054
  • [34] Development of a high-performance liquid chromatography-based assay for carotenoids in human red blood cells: Application to clinical studies
    Nakagawa, Kiyotaka
    Kiko, Takehiro
    Hatade, Keijiro
    Asai, Akira
    Kimura, Fumiko
    Sookwong, Phumon
    Tsuduki, Tsuyoshi
    Arai, Hiroyuki
    Miyazawa, Teruo
    ANALYTICAL BIOCHEMISTRY, 2008, 381 (01) : 129 - 134
  • [35] Tetrahydrocurcumin in plasma and urine: Quantitation by high performance liquid chromatography
    Heath, DD
    Pruitt, MA
    Brenner, DE
    Begum, AN
    Frautschy, SA
    Rock, CL
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2): : 206 - 212
  • [36] Determination of malondialdehyde in biological samples by solid-phase extraction and high-performance liquid chromatography
    Bakalova, R
    Mileva, M
    Kotsev, C
    Bardarov, V
    Ribarov, S
    METHODS AND FINDINGS IN EXPERIMENTAL AND CLINICAL PHARMACOLOGY, 2000, 22 (05): : 267 - 269
  • [37] Hemoglobin variants and high-performance liquid chromatography
    Nair, S.
    Nadkarni, A. H.
    Ghosh, K.
    Colah, R.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 (05) : E13 - E14
  • [38] High-performance liquid chromatography-based characterization of fengycin produced by Bacillus amyloliquefaciens against Fusarium graminearum and Rhizoctonia solani
    Khan, Muddasir
    Salman, Muhammad
    Abdullah
    KUWAIT JOURNAL OF SCIENCE, 2022, 49 (04) : 172 - 185
  • [39] Simple and sensitive high-performance liquid chromatography method for the quantitation of indinavir in rat plasma and central nervous system
    Hamidi, M
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (05) : 620 - 627
  • [40] Influence of citrate and EDTA anticoagulants on plasma malondialdehyde concentrations estimated by high-performance liquid chromatography
    Suttnar, J
    Másová, L
    Dyr, JE
    JOURNAL OF CHROMATOGRAPHY B, 2001, 751 (01): : 193 - 197