Quantitation of malondialdehyde in gingival crevicular fluid by a high-performance liquid chromatography-based method

被引:37
|
作者
Bastos, Alliny Souza [1 ]
de Melo Loureiro, Ana Paula [2 ]
de Oliveira, Tiago Franco [2 ]
Tfaile Corbi, Samia Cruz [1 ]
Scarel Caminaga, Raquel Mantuaneli [3 ]
Rossa Junior, Carlos [1 ]
Orrico, Silvana R. P. [1 ]
机构
[1] Univ Estadual Paulista UNESP, Araraquara Sch Dent, Dept Diag & Surg, BR-14801903 Sao Paulo, Brazil
[2] Univ Sao Paulo, Fac Pharmaceut Sci, Dept Clin & Toxicol Anal, BR-05508900 Sao Paulo, Brazil
[3] Univ Estadual Paulista UNESP, Araraquara Sch Dent, Dept Morphol, BR-14801903 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Lipid peroxidation; Malondialdehyde; Periodontal diseases; Gingival crevicular fluid; HPLC; LIPID-PEROXIDATION LEVELS; TOTAL OXIDANT STATUS; OXIDATIVE STRESS; CHRONIC PERIODONTITIS; PLASMA; DISEASE; SALIVA; SERUM; COMPLICATIONS; MALONALDEHYDE;
D O I
10.1016/j.ab.2012.01.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Lipid peroxidation (LPO) has been associated with periodontal disease, and the evaluation of malondialdehyde (MDA) in the gingival crevicular fluid (GCF), an inflammatory exudate from the surrounding tissue of the periodontium, may be useful to clarify the role of LPO in the pathogenesis of periodontal disease. We describe the validation of a method to measure MDA in the GCF using high-performance liquid chromatography. MDA calibration curves were prepared with phosphate-buffered solution spiked with increasing known concentrations of MDA. Healthy and diseased GCF samples were collected from the same patient to avoid interindividual variability. MDA response was linear in the range measured, and excellent agreement was observed between added and detected concentrations of MDA. Samples' intra- and interday coefficients of variation were below 6.3% and 12.4%, respectively. The limit of quantitation (signal/noise = 5) was 0.03 mu M. When the validated method was applied to the GCF, excellent agreement was observed in the MDA quantitation from healthy and diseased sites, and diseased sites presented more MDA than healthy sites (P < 0.05). In this study, a validated method for MDA quantitation in GCF was established with satisfactory sensitivity, precision, and accuracy. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [21] The simple and sensitive measurement of malondialdehyde in selected specimens of biological origin and some feed by reversed phase high performance liquid chromatography
    Czauderna, Marian
    Kowalczyk, Jan
    Marounek, Milan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (23): : 2251 - 2258
  • [22] Simultaneous Quantitation of Organic Acids and Monosaccharides by High-Performance Liquid Chromatography
    Lu Xin
    Hagiwara, Shoji
    Song Guohui
    Huang Jinian
    Nabetani, Hiroshi
    Li Ruihong
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON CHEMICAL, MATERIAL AND FOOD ENGINEERING, 2015, 22 : 380 - 388
  • [23] High performance liquid chromatography-based method to analyze activity of GABA transporters in central nervous system
    Moraes, Edinaldo Rogerio da Silva
    Santos-Silva, Mateus
    Grisolia, Alan Araujo
    Braga, Danielle Valente
    Leao, Luana Ketlen Reis
    Bahia, Carlomagno Pacheco
    de Moraes, Suellen Alessa Soares
    Passos, Adelaide Fonseca
    Batista, Evander de Jesus Oliveira
    Herculano, Anderson Manoel
    Oliveira, Karen Renata Herculano Matos
    NEUROCHEMISTRY INTERNATIONAL, 2022, 158
  • [24] Determination of ceftriaxone concentration in human cerebrospinal fluid by high-performance liquid chromatography with UV detection
    Kotani, Akira
    Hirai, Jun
    Hamada, Yukihiro
    Fujita, Jiro
    Hakamata, Hideki
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1124 : 161 - 164
  • [25] Sensitive determination of malondialdehyde in rat prostate by high performance liquid chromatography with fluorescence detection
    Dong, Xiuli
    Tang, Jiayuan
    Chen, Xiangming
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [26] Improvement in the high-performance liquid chromatography malondialdehyde level determination in normal human plasma
    Volpi, N
    Tarugi, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 713 (02): : 433 - 437
  • [27] Determination of malondialdehyde (MDA) by high-performance liquid chromatography in serum and liver as a biomarker for oxidative stress - Application to a rat model for hypercholesterolemia and evaluation of the effect of diets rich in phenolic antioxidants from fruits
    Mateos, R
    Lecumberri, E
    Ramos, S
    Goya, L
    Bravo, L
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 827 (01): : 76 - 82
  • [28] Nuclease P1 digestion/high-performance liquid chromatography, a practical method for DNA quantitation
    Shimelis, Olga
    Giese, Roger W.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1117 (02) : 132 - 136
  • [29] Performance Characteristics of a New Levetiracetam Immunoassay and Method Comparison With a High-Performance Liquid Chromatography Method
    Reineks, Edmunds Z.
    Lawson, Susan E.
    Lembright, Katherine E.
    Wang, Sihe
    THERAPEUTIC DRUG MONITORING, 2011, 33 (01) : 124 - 127
  • [30] Quantitation and purification of polymerase chain reaction products by high-performance liquid chromatography
    Katz, ED
    MOLECULAR BIOTECHNOLOGY, 1996, 6 (01) : 79 - 86