Quantitation of malondialdehyde in gingival crevicular fluid by a high-performance liquid chromatography-based method

被引:37
|
作者
Bastos, Alliny Souza [1 ]
de Melo Loureiro, Ana Paula [2 ]
de Oliveira, Tiago Franco [2 ]
Tfaile Corbi, Samia Cruz [1 ]
Scarel Caminaga, Raquel Mantuaneli [3 ]
Rossa Junior, Carlos [1 ]
Orrico, Silvana R. P. [1 ]
机构
[1] Univ Estadual Paulista UNESP, Araraquara Sch Dent, Dept Diag & Surg, BR-14801903 Sao Paulo, Brazil
[2] Univ Sao Paulo, Fac Pharmaceut Sci, Dept Clin & Toxicol Anal, BR-05508900 Sao Paulo, Brazil
[3] Univ Estadual Paulista UNESP, Araraquara Sch Dent, Dept Morphol, BR-14801903 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Lipid peroxidation; Malondialdehyde; Periodontal diseases; Gingival crevicular fluid; HPLC; LIPID-PEROXIDATION LEVELS; TOTAL OXIDANT STATUS; OXIDATIVE STRESS; CHRONIC PERIODONTITIS; PLASMA; DISEASE; SALIVA; SERUM; COMPLICATIONS; MALONALDEHYDE;
D O I
10.1016/j.ab.2012.01.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Lipid peroxidation (LPO) has been associated with periodontal disease, and the evaluation of malondialdehyde (MDA) in the gingival crevicular fluid (GCF), an inflammatory exudate from the surrounding tissue of the periodontium, may be useful to clarify the role of LPO in the pathogenesis of periodontal disease. We describe the validation of a method to measure MDA in the GCF using high-performance liquid chromatography. MDA calibration curves were prepared with phosphate-buffered solution spiked with increasing known concentrations of MDA. Healthy and diseased GCF samples were collected from the same patient to avoid interindividual variability. MDA response was linear in the range measured, and excellent agreement was observed between added and detected concentrations of MDA. Samples' intra- and interday coefficients of variation were below 6.3% and 12.4%, respectively. The limit of quantitation (signal/noise = 5) was 0.03 mu M. When the validated method was applied to the GCF, excellent agreement was observed in the MDA quantitation from healthy and diseased sites, and diseased sites presented more MDA than healthy sites (P < 0.05). In this study, a validated method for MDA quantitation in GCF was established with satisfactory sensitivity, precision, and accuracy. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [1] A Fast and Validated Method for the Determination of Malondialdehyde in Fish Liver Using High-Performance Liquid Chromatography with a Photodiode Array Detector
    Faizan, Mohammad
    Esatbeyoglu, Tuba
    Bayram, Banu
    Rimbach, Gerald
    JOURNAL OF FOOD SCIENCE, 2014, 79 (04) : C484 - C488
  • [2] DISACCHARIDE ANALYSIS OF CHONDROITIN SULFATE IN HUMAN GINGIVAL CREVICULAR FLUID USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    OKAZAKI, J
    KAMADA, A
    MATSUKAWA, F
    SAKAKI, T
    GONDA, Y
    ARCHIVES OF ORAL BIOLOGY, 1995, 40 (08) : 777 - 779
  • [3] Measurement of total and free malondialdehyde by gas-chromatography mass spectrometry - comparison with high-performance liquid chromatography methology
    Zelzer, S.
    Oberreither, R.
    Bernecker, C.
    Stelzer, I.
    Truschnig-Wilders, M.
    Fauler, G.
    FREE RADICAL RESEARCH, 2013, 47 (08) : 651 - 656
  • [4] Total plasma malondialdehyde levels in 16 Taiwanese college students determined by various thiobarbituric acid tests and an improved high-performance liquid chromatography-based method
    Hong, YL
    Yeh, SL
    Chang, CY
    Hu, ML
    CLINICAL BIOCHEMISTRY, 2000, 33 (08) : 619 - 625
  • [5] Measurement of malondialdehyde levels in food by high-performance liquid chromatography with fluorometric detection
    Bergamo, P
    Fedele, E
    Balestrieri, M
    Abrescia, P
    Ferrara, L
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1998, 46 (06) : 2171 - 2176
  • [6] Development and evaluation of a liquid chromatography-mass spectrometry method for rapid, accurate quantitation of malondialdehyde in human plasma
    Sobsey, Constance A.
    Han, Jun
    Lin, Karen
    Swardfager, Walter
    Levitt, Anthony
    Borchers, Christoph H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1029 : 205 - 212
  • [7] Determination of free malondialdehyde in human serum by high-performance liquid chromatography
    Karatas, F
    Karatepe, M
    Baysar, A
    ANALYTICAL BIOCHEMISTRY, 2002, 311 (01) : 76 - 79
  • [8] ASSAY OF ASCORBIC-ACID IN HUMAN CREVICULAR FLUID FROM CLINICALLY HEALTHY GINGIVAL SITES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MEYLE, J
    KAPITZA, K
    ARCHIVES OF ORAL BIOLOGY, 1990, 35 (04) : 319 - 323
  • [9] Quantitation of acetazolamide in rat plasma, brain tissue and cerebrospinal fluid by high-performance liquid chromatography
    Ichikawa, N
    Naora, K
    Hirano, H
    Iwamoto, K
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (08) : 1415 - 1421
  • [10] High-performance liquid chromatography-based method to evaluate kinetics of glucosinolate hydrolysis by Sinapis alba myrosinase
    Vastenhout, Kayla J.
    Tornberg, Ruthellen H.
    Johnson, Amanda L.
    Amolins, Michael W.
    Mays, Jared R.
    ANALYTICAL BIOCHEMISTRY, 2014, 465 : 105 - 113