A novel urethral sparing technique for high-dose-rate prostate brachytherapy after transurethral resection of the prostate

被引:0
|
作者
Kunogi, Hiroaki [1 ,2 ]
Cunha, Jason Adam M. [1 ]
Chang, Albert J. [1 ]
Gadzinski, Adam J. [3 ]
Shinohara, Katsuto [3 ]
Hsu, I-Chow [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, 1600 Divisadero St,H1031, San Francisco, CA 94143 USA
[2] Juntendo Univ, Dept Radiat Oncol, Bunkyo Ku, Tokyo, Japan
[3] Univ Calif San Francisco, Dept Urol, San Francisco, CA USA
关键词
Brachytherapy; HDR; Prostate; TURP; Urinary catheter; CANCER; RADIOTHERAPY; TOXICITY;
D O I
10.1016/j.brachy.2017.07.017
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: The purpose of this study was to assess retrospectively the variability of the urethral dose optimized using a Foley catheter versus urethral contrast injected using a new modified triple-lumen catheter, in CT-based high-dose-rate (HDR) prostate brachytherapy of posttransurethral resection of prostate (TURP) patients. METHODS AND MATERIALS: At our institution, there were six post-TURP patients with prostate carcinoma between July 2014 and April 2016 who underwent transperineal interstitial HDR brachytherapy (16 needles). A custom modified triple-lumen catheter was placed to inject contrast into the TURP defect. Three-dimensional optimal plans using inverse planning simulated annealing algorithm was generated according to radiation therapy oncology group dose requirements. Alternative plans were retroactively generated for comparison using standard technique based on a Foley catheter as a urethral constraint volume for each patient with the same weighting factors. We compared the dosimetry parameters in each planning using Wilcoxon's ranked sum nonparametric test. RESULTS: The median followup of all patients was 17.5 months. No significant genitourinary or gastrointestinal toxicity was noted using this technique. In the dosimetric analysis, the prostate V-100 values and TURP urethral V100 were significantly different between plans with and without the contrast (V100 [mean]: 92.4 [%] vs. 94.4 [%], p = 0.046; TURP UV100 [mean]: 1.4 cc vs. 2.2 cc, p = 0.028). There were no statistical differences in the mean values of planning target volume V-150%, V(20)0%, and D-90, and each bladder V-75 and rectum (V75). CONCLUSIONS: Post-TURP HDR brachytherapy with urethral contrast showed significantly more volume effect of the TURP defect than that with a Foley catheter alone. Better visualization of the TURP defect should lead to more accurate urethral sparing administration of HDR brachytherapy which is necessary to prevent urethral complication. (C) 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1113 / 1118
页数:6
相关论文
共 50 条
  • [41] Urinary incontinence after high-dose-rate brachytherapy boost treatment for prostate cancer
    Kragelj, Borut
    Zaletel-Kragelj, Lijana
    BRACHYTHERAPY, 2016, 15 (04) : 442 - 449
  • [42] Salvage High-Dose-Rate Brachytherapy for Recurrent Prostate Cancer After Definitive Radiation
    Wu, Susan Y.
    Wong, Anthony C.
    Shinohara, Katsuto
    Roach, Mack, III
    Cunha, Adam M.
    Valdes, Gilmer
    Hsu, I-Chow
    PRACTICAL RADIATION ONCOLOGY, 2021, 11 (06) : 515 - 526
  • [43] Dosimetric effect of external beam planning preceding combined high-dose-rate brachytherapy of the prostate
    Martin, Jarad M.
    Brett, Richard
    Blyth, Jemma
    Morrison, Stewart
    Bryant, Daniel
    Plank, Ashley
    Cheuk, Robyn
    Fay, Michael
    Dickie, Graeme
    Yaxley, John
    BRACHYTHERAPY, 2011, 10 (06) : 474 - 478
  • [44] The effects of low- and high-dose-rate brachytherapy on depressive symptoms in prostate cancer patients
    Sharpley, Christopher F.
    Christie, David H. R.
    Bitsika, Vicki
    Oar, Andrew J.
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2014, 19 (06) : 1080 - 1084
  • [45] High-dose-rate brachytherapy in combination with conformal external beam radiotherapy in the treatment of prostate cancer
    Zwahlen, Daniel R.
    Andrianopoulos, Nick
    Matheson, Bronwyn
    Duchesne, Gillian M.
    Millar, Jeremy L.
    BRACHYTHERAPY, 2010, 9 (01) : 27 - 35
  • [46] High dose rate prostate brachytherapy
    Nickers, P.
    Blanchard, P.
    Hannoun-Levi, J-M
    Bossi, A.
    Chapet, O.
    Guerif, S.
    CANCER RADIOTHERAPIE, 2013, 17 (02): : 118 - 124
  • [47] Comparison of dose and catheter optimization algorithms in prostate high-dose-rate brachytherapy
    Poulin, Eric
    Varfalvy, Nicolas
    Aubin, Sylviane
    Beaulieu, Luc
    BRACHYTHERAPY, 2016, 15 (01) : 102 - 111
  • [48] High dose rate brachytherapy boost for prostate cancer: Biochemical control and the impact of transurethral resection of the prostate and hydrogel spacer insertion on toxicity outcomes
    Chao, Michael
    Bolton, Damien
    Joon, Daryl Lim
    Chan, Yee
    Lawrentschuk, Nathan
    Ho, Huong
    Spencer, Sandra
    Wasiak, Jason
    Guerrieri, Mario
    Ow, Darren
    Troy, Andrew
    Trung Pham
    Sengupta, Shomik
    Tan, Alwin
    McMillan, Kevin
    Koufogiannis, George
    Foroudi, Farshad
    Ng, Michael
    Khoo, Vincent
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2019, 63 (03) : 415 - 421
  • [49] Can high-dose-rate brachytherapy prevent the major genitourinary complication better than external beam radiation alone for patients with previous transurethral resection of prostate?
    Luo, Hao Lun
    Fang, Fu Min
    Kang, Chih Hsiung
    Chuang, Yao Chi
    Chiang, Po Hui
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2013, 45 (01) : 113 - 119
  • [50] Effect of transurethral resection on urinary quality of life after permanent prostate brachytherapy
    Merrick, GS
    Butler, WM
    Wallner, KE
    Galbreath, RW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (01): : 81 - 88