Contactless Measurement of Vital Signs Using Thermal and RGB Cameras: A Study of COVID 19-Related Health Monitoring

被引:17
作者
Yang, Fan [1 ]
He, Shan [1 ]
Sadanand, Siddharth [2 ]
Yusuf, Aroon [3 ]
Bolic, Miodrag [1 ]
机构
[1] Univ Ottawa, Sch Elect Engn & Comp Sci, Hlth Devices Res Grp HDRG, Ottawa, ON K1N 6N5, Canada
[2] Ryerson Univ, Inst Biomed Engn Sci & Technol iBEST, St Michaels Hosp, Toronto, ON M5B 1T8, Canada
[3] WelChek Inc, Mississauga, ON L4W 4Y8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
vital signs; heart rate (HR); respiration rate (RR); body temperature (BT); face detection; image processing; signal processing; RESPIRATORY RATE; NONCONTACT;
D O I
10.3390/s22020627
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a contactless vital signs monitoring system was proposed, which can measure body temperature (BT), heart rate (HR) and respiration rate (RR) for people with and without face masks using a thermal and an RGB camera. The convolution neural network (CNN) based face detector was applied and three regions of interest (ROIs) were located based on facial landmarks for vital sign estimation. Ten healthy subjects from a variety of ethnic backgrounds with skin colors from pale white to darker brown participated in several different experiments. The absolute error (AE) between the estimated HR using the proposed method and the reference HR from all experiments is 2.70 & PLUSMN;2.28 beats/min (mean & PLUSMN; std), and the AE between the estimated RR and the reference RR from all experiments is 1.47 & PLUSMN;1.33 breaths/min (mean & PLUSMN; std) at a distance of 0.6-1.2 m.
引用
收藏
页数:17
相关论文
共 29 条
  • [11] Kwon S, 2012, IEEE ENG MED BIO, P2174, DOI 10.1109/EMBC.2012.6346392
  • [12] Lewandowska M., 2011, 2011 Federated Conference on Computer Science and Information Systems (FedCSIS), P405
  • [13] Remote Heart Rate Measurement From Face Videos Under Realistic Situations
    Li, Xiaobai
    Chen, Jie
    Zhao, Guoying
    Pietikainen, Matti
    [J]. 2014 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2014, : 4264 - 4271
  • [14] Muhammad U., 2019, BMJ OPEN RESPIR RES, V6, DOI [10.1136/bmjresp-2019-bssconf.16, DOI 10.1136/BMJRESP-2019-BSSCONF.16]
  • [15] IR thermography-based monitoring of respiration phase without image segmentation
    Mutlu, K.
    Rabell, J. Esquivelzeta
    del Olmo, P. Martin
    Haesler, S.
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2018, 301 : 1 - 8
  • [16] Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
    Poh, Ming-Zher
    McDuff, Daniel J.
    Picard, Rosalind W.
    [J]. OPTICS EXPRESS, 2010, 18 (10): : 10762 - 10774
  • [17] Tidal Volume and Instantaneous Respiration Rate Estimation using a Volumetric Surrogate Signal Acquired via a Smartphone Camera
    Reyes, Bersain A.
    Reljin, Natasa
    Kong, Youngsun
    Nam, Yunyoung
    Chon, Ki H.
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2017, 21 (03) : 764 - 777
  • [18] Realization of the Contrast Limited Adaptive Histogram Equalization (CLAHE) for real-time image enhancement
    Reza, AM
    [J]. JOURNAL OF VLSI SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2004, 38 (01): : 35 - 44
  • [19] Remote heart rate measurement using low-cost RGB face video: a technical literature review
    Rouast, Philipp V.
    Adam, Marc T. P.
    Chiong, Raymond
    Cornforth, David
    Lux, Ewa
    [J]. FRONTIERS OF COMPUTER SCIENCE, 2018, 12 (05) : 858 - 872
  • [20] Multispectral Video Fusion for Non-Contact Monitoring of Respiratory Rate and Apnea
    Scebba, Gaetano
    Poian, Giulia
    Karlen, Walter
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (01) : 350 - 359