Testing a Quaternion Conversion Method to Determine Human Three-Dimensional Tibiofemoral Angles During an In Vitro Simulated Jump Landing

被引:3
作者
Ajdaroski, Mirel [1 ]
Ashton-Miller, James A. [2 ]
Baek, So Young [2 ]
Shahshahani, Payam Mirshams [2 ]
Esquivel, Amanda O. [1 ]
机构
[1] Univ Michigan, Dept Mech Engn, 4901 Evergreen Rd, Dearborn, MI 48128 USA
[2] Univ Michigan, Dept Mech Engn, George G Brown Lab, 3443 GGB,2350 Hayward St, Ann Arbor, MI 48109 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2022年 / 144卷 / 04期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
CRUCIATE LIGAMENT INJURIES; MECHANISMS; RISK; GAIT;
D O I
10.1115/1.4052496
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Lower limb joint kinematics have been measured in laboratory settings using fixed camera-based motion capture systems; however, recently inertial measurement units (IMUs) have been developed as an alternative. The purpose of this study was to test a quaternion conversion (QC) method for calculating the three orthogonal knee angles during the high velocities associated with a jump landing using commercially available IMUs. Nine cadaveric knee specimens were instrumented with APDM Opal IMUs to measure knee kinematics in one-legged 3-4x bodyweight simulated jump landings, four of which were used in establishing the parameters (training) for the new method and five for validation (testing). We compared the angles obtained from the QC method to those obtained from a commercially available sensor and algorithm (APDM Opal) with those calculated from an active marker motion capture system. Results showed a significant difference between both IMU methods and the motion capture data in the majority of orthogonal angles (p < 0.01), though the differences between the QC method and Certus system in the testing set for flexion and rotation angles were smaller than the APDM Opal algorithm, indicating an improvement. Additionally, in all three directions, both the limits of agreement and root-mean-square error between the QC method and the motion capture system were smaller than between the commercial algorithm and the motion capture.
引用
收藏
页数:8
相关论文
共 38 条
[1]   Validation of a Device to Measure Knee Joint Angles for a Dynamic Movement [J].
Ajdaroski, Mirel ;
Tadakala, Ruchika ;
Nichols, Lorraine ;
Esquivel, Amanda .
SENSORS, 2020, 20 (06)
[2]   Arthroscopically Pertinent Anatomy of the Anterolateral and Posteromedial Bundles of the Posterior Cruciate Ligament [J].
Anderson, Colin J. ;
Ziegler, Connor G. ;
Wijdicks, Coen A. ;
Engebretsen, Lars ;
LaPrade, Robert F. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (21) :1936-1945
[3]   Physical Activities Monitoring Using Wearable Acceleration Sensors Attached to the Body [J].
Arif, Muhammad ;
Kattan, Ahmed .
PLOS ONE, 2015, 10 (07)
[4]   Expressing angles relative to reference postures: A mathematical comparison of four approaches [J].
Barrett, Jeff M. ;
Viggiani, Daniel ;
Park, Jonathan ;
Callaghan, Jack P. .
JOURNAL OF BIOMECHANICS, 2020, 104
[5]   ACL Tears in School-Aged Children and Adolescents Over 20 Years [J].
Beck, Nicholas A. ;
Lawrence, J. Todd R. ;
Nordin, James D. ;
Defor, Terese A. ;
Tompkins, Marc .
PEDIATRICS, 2017, 139 (03)
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   Noncontact Anterior Cruciate Ligament Injuries: Mechanisms and Risk Factors [J].
Boden, Barry P. ;
Sheehan, Frances T. ;
Torg, Joseph S. ;
Hewett, Timothy E. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2010, 18 (09) :520-527
[8]   'Outwalk': a protocol for clinical gait analysis based on inertial and magnetic sensors [J].
Cutti, Andrea Giovanni ;
Ferrari, Alberto ;
Garofalo, Pietro ;
Raggi, Michele ;
Cappello, Angelo ;
Ferrari, Adriano .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (01) :17-25
[9]   Correlation between ground reaction force and tibial acceleration in vertical jumping [J].
Elvin, Niell G. ;
Elvin, Alex A. ;
Arnoczky, Steven P. .
JOURNAL OF APPLIED BIOMECHANICS, 2007, 23 (03) :180-189
[10]   Evaluation of a mixed approach combining stationary and wearable systems to monitor gait over long distance [J].
Favre, J. ;
Crevoisier, X. ;
Jolles, B. M. ;
Aminian, K. .
JOURNAL OF BIOMECHANICS, 2010, 43 (11) :2196-2202