The Non-Destructive Test of Steel Corrosion in Reinforced Concrete Bridges Using a Micro-Magnetic Sensor

被引:90
作者
Zhang, Hong [1 ]
Liao, Leng [2 ]
Zhao, Ruiqiang [2 ]
Zhou, Jianting [1 ]
Yang, Mao [3 ]
Xia, Runchuan [1 ]
机构
[1] Chongqing Jiaotong Univ, Coll Civil Engn, Chongqing 400074, Peoples R China
[2] Chongqing Jiaotong Univ, Sch Mat Sci & Engn, Chongqing 400074, Peoples R China
[3] Chongqing Three Gorges Univ, Coll Civil Engn, Chongqing 404100, Peoples R China
基金
中国国家自然科学基金;
关键词
steel corrosion; non-destructive test; micro-magnetic sensor; self-magnetic flux leakage; numerical simulation; MEMORY;
D O I
10.3390/s16091439
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a non-destructive test method for steel corrosion in reinforced concrete bridges by using a 3-dimensional digital micro-magnetic sensor to detect and analyze the self-magnetic field leakage from corroded reinforced concrete. The setup of the magnetic scanning device and the measurement mode of the micro-magnetic sensor are introduced. The numerical analysis model is also built based on the linear magnetic charge theory. Compared to the self-magnetic field leakage data obtained from magnetic sensor-based measurement and numerical calculation, it is shown that the curves of tangential magnetic field at different lift-off height all intersect near the edge of the steel corrosion zone. The result indicates that the intersection of magnetic field curves can be used to detect and evaluate the range of the inner steel corrosion in engineering structures. The findings of this work propose a new and effective non-destructive test method for steel corrosion, and therefore enlarge the application of the micro-magnetic sensor.
引用
收藏
页数:9
相关论文
共 23 条
[1]  
Bergamini A., 2003, P SPIE
[2]   A study of metal properties using the method of magnetic memory [J].
Dubov, AA .
METAL SCIENCE AND HEAT TREATMENT, 1997, 39 (9-10) :401-405
[3]  
Fitzgerald C. S., 1995, P SPIE
[4]  
FORSTER F, 1982, SOV J NONDESTR TEST+, V18, P841
[5]  
Hall DR, 2003, INSIGHT, V45, P471
[6]   Fast Estimation of Defect Profiles from the Magnetic Flux Leakage Signal Based on a Multi-Power Affine Projection Algorithm [J].
Han, Wenhua ;
Shen, Xiaohui ;
Xu, Jun ;
Wang, Ping ;
Tian, Guiyun ;
Wu, Zhengyang .
SENSORS, 2014, 14 (09) :16454-16466
[7]   Corrosion detection in reinforced concrete using induction heating and infrared thermography [J].
Kobayashi K. ;
Banthia N. .
Journal of Civil Structural Health Monitoring, 2011, 1 (1-2) :25-35
[8]  
Krieger J., 1999, P SPIE
[9]   ESTIMATION OF RESIDUAL-STRESSES IN RAILWAY WHEELS BY MEANS OF STRESS-INDUCED MAGNETIC-ANISOTROPY [J].
LANGMAN, RA ;
MUTTON, PJ .
NDT & E INTERNATIONAL, 1993, 26 (04) :195-205
[10]   DETERMINATION OF CORROSION RATES BY ELECTROCHEMICAL DC AND AC METHODS [J].
LORENZ, WJ ;
MANSFELD, F .
CORROSION SCIENCE, 1981, 21 (9-10) :647-672