Impact of Time-of-Use Demand Response Program on Optimal Operation of Afghanistan Real Power System

被引:12
作者
Sediqi, Mohammad Masih [1 ]
Nakadomari, Akito [1 ]
Mikhaylov, Alexey [2 ]
Krishnan, Narayanan [3 ]
Lotfy, Mohammed Elsayed [1 ,4 ]
Yona, Atsushi [1 ]
Senjyu, Tomonobu [1 ]
机构
[1] Univ Ryukyus, Fac Engn, 1 Senbaru,Nishihara Cho, Nakagami, Okinawa 9030213, Japan
[2] Minist Finance Russian Federat, Financial Res Inst, Moscow 127006, Russia
[3] SASTRA Deemed Univ, Dept Elect & Elect Engn, Thanjavur 613401, India
[4] Zagazig Univ, Elect Power & Machines Dept, Zagazig 44519, Egypt
关键词
time-of-use demand response; optimal operation; price elasticity; renewable energy sources; genetic algorithm; CONSTRAINED UNIT COMMITMENT; OPTIMIZATION; RATES; PEAK;
D O I
10.3390/en15010296
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Like most developing countries, Afghanistan still employs the traditional philosophy of supplying all its load demands whenever they happen. However, to have a reliable and cost-effective system, the new approach proposes to keep the variations of demand at the lowest possible level. The power system infrastructure requires massive capital investment; demand response (DR) is one of the economic options for running the system according to the new scheme. DR has become the intention of many researchers in developed countries. However, very limited works have investigated the employment of appropriate DR programs for developing nations, particularly considering renewable energy sources (RESs). In this paper, as two-stage programming, the effect of the time-of-use demand response (TOU-DR) program on optimal operation of Afghanistan real power system in the presence of RESs and pumped hydropower storage (PHS) system in the day-ahead power market is analyzed. Using the concept of price elasticity, first, an economic model indicating the behaviour of customers involved in TOU-DR program is developed. A genetic algorithm (GA) coded in MATLAB software is used accordingly to schedule energy and reserve so that the total operation cost of the system is minimized. Two simulation cases are considered to verify the effectiveness of the suggested scheme. The first stage programming approach leads case 2 with TOU-DR program to 35 MW (811 MW - 776 MW), $16,235 ($528,825 - $512,590), and 64 MW reductions in the peak load, customer bill and peak to valley distance, respectively compared to case 1 without TOU-DR program. Also, the simulation results for stage 2 show that by employing the TOU-DR program, the system's total cost can be reduced from $317,880 to $302,750, which indicates a significant reduction in thermal units' operation cost, import power tariffs and reserve cost.
引用
收藏
页数:21
相关论文
共 50 条
[31]   Real-Time Optimal Operation of Multiple Reservoirs System [J].
Opan, Mucahita .
TEKNIK DERGI, 2011, 22 (02) :5359-5385
[32]   Optimal Real-Time Pricing of Electricity Based on Demand Response [J].
Jiang, Jiangfeng ;
Kou, Yu ;
Bie, Zhaohong ;
Li, Gengfeng .
RENEWABLE ENERGY INTEGRATION WITH MINI/MICROGRID, 2019, 159 :304-308
[33]   Optimal operation of a micro-grid containing energy resources and demand response program [J].
Jafari, E. ;
Soleymani, S. ;
Mozafari, B. ;
Amraee, Turaj .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2018, 15 (10) :2169-2182
[34]   Optimized Combined Heat and Power Dispatch Considering Decreasing Carbon Emission by Coordination of Heat Load Elasticity and Time-of-use Demand Response [J].
Zhu W. ;
Luo Y. ;
Hu B. ;
Luo H. ;
Zhang Y. ;
Han Y. ;
Tang M. ;
Tong Q. .
Dianwang Jishu/Power System Technology, 2021, 45 (10) :3803-3812
[35]   Optimal operation of power system incorporating wind energy with demand side management [J].
Alham, M. H. ;
Elshahed, M. ;
Ibrahim, Doaa Khalil ;
El Zahab, Essam El Din Abo .
AIN SHAMS ENGINEERING JOURNAL, 2017, 8 (01) :1-7
[36]   A multi-timescale optimal operation strategy for an integrated energy system considering integrated demand response and equipment response time [J].
Dong, Fugui ;
Meng, Zihang ;
Chi, Laihao ;
Wang, Xiaofeng .
JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2023, 15 (04)
[37]   Microgrid system energy management with demand response program for clean and economical operation [J].
Dey, Bishwajit ;
Misra, Srikant ;
Marquez, Fausto Pedro Garcia .
APPLIED ENERGY, 2023, 334
[38]   Research on Optimal Control Operation of Energy Storage System Considering Demand Response [J].
Li, Yingjie .
2021 IEEE 4TH INTERNATIONAL CONFERENCE ON AUTOMATION, ELECTRONICS AND ELECTRICAL ENGINEERING, AUTEEE, 2021, :105-108
[39]   Optimal Operation for Integrated Energy System on User Side Considering Demand Response [J].
Hui, Hengyu ;
Zhang, Lijun ;
Shi, Xiao ;
Xie, Kang ;
Zhou, Xing ;
Zhang, Xizhu ;
Yin, Xunhu .
2020 IEEE STUDENT CONFERENCE ON ELECTRIC MACHINES AND SYSTEMS (SCEMS 2020), 2020, :875-880
[40]   Optimal Operation of CHP Microgrid with Concentrating Solar Power Plants Considering Demand Response [J].
Wang J. ;
Shi J. ;
Wen F. ;
Li J. ;
Zhang L. ;
Xu C. .
Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (01) :176-185