Anatomic and Functional Imaging Using Row-Column Arrays

被引:46
作者
Jensen, Jorgen Arendt [1 ]
Schou, Mikkel [1 ]
Jorgensen, Lasse Thurmann [1 ]
Tomov, Borislav G. [1 ]
Stuart, Matthias Bo [1 ]
Traberg, Marie Sand [1 ]
Taghavi, Iman [1 ]
Oygaard, Sigrid Huesebo [2 ]
Ommen, Martin Lind [3 ]
Steenberg, Kitty [3 ]
Thomsen, Erik Vilain [3 ]
Panduro, Nathalie Sarup [4 ]
Nielsen, Michael Bachmann [5 ]
Sorensen, Charlotte Mehlin [4 ]
机构
[1] Tech Univ Denmark, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[2] Dolphitech, N-2815 Gjovik, Norway
[3] Tech Univ Denmark, Dept Hlth Technol, MEMS Grp, DK-2800 Lyngby, Denmark
[4] Univ Copenhagen, Dept Biomed Sci, DK-2100 Copenhagen, Denmark
[5] Rigshosp, Dept Radiol, DK-2100 Copenhagen, Denmark
基金
欧洲研究理事会;
关键词
Beam forming; row-column (RC) arrays; super resolution; ultrasound; velocity measurement; ADDRESSED 2-D ARRAYS; ACOUSTIC SUPERRESOLUTION; MOTION-CORRECTION; CMUT ARRAYS; ULTRASOUND; VELOCITY; TRANSDUCER; DESIGN; SYSTEM;
D O I
10.1109/TUFFC.2022.3191391
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming. Resolution can approach the diffraction limit with an isotropic resolution of half a wavelength with low sidelobe levels, and the field of view can be expanded by using convex or lensed RC probes. GPU beamforming allows for three orthogonal planes to be beamformed at 30 Hz, providing near real-time imaging ideal for positioning the probe and improving the operator's workflow. Functional imaging is also attainable using transverse oscillation and dedicated SA sequence for tensor velocity imaging for revealing the full 3-D velocity vector as a function of spatial position and time for both blood velocity and tissue motion estimation. Using RC arrays with commercial contrast agents can reveal super-resolution imaging (SRI) with isotropic resolution below 20 mu m. RC arrays can, thus, yield full 3-0 imaging at high resolution, contrast, and volumetric rates for both anatomic and functional imaging with the same number of receive channels as current commercial 1-D arrays.
引用
收藏
页码:2722 / 2738
页数:17
相关论文
共 93 条
[1]   Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images [J].
Ackermann, Dimitri ;
Schmitz, Georg .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (01) :72-82
[2]   Evaluation of 2D super-resolution ultrasound imaging of the rat renal vasculature using ex vivo micro-computed tomography [J].
Andersen, Sofie Bech ;
Taghavi, Iman ;
Kjer, Hans Martin ;
Sogaard, Stinne Byrholdt ;
Gundlach, Carsten ;
Dahl, Vedrana Andersen ;
Nielsen, Michael Bachmann ;
Dahl, Anders Bjorholm ;
Jensen, Jorgen Arendt ;
Sorensen, Charlotte Mehlin .
SCIENTIFIC REPORTS, 2021, 11 (01)
[3]   Sparse 2-D Arrays for 3-D phased array imaging - Design methods [J].
Austeng, A ;
Holm, S .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) :1073-1086
[4]   3-D Spatial Compounding Using a Row-Column Array [J].
Awad, Samer I. ;
Yen, Jesse T. .
ULTRASONIC IMAGING, 2009, 31 (02) :120-130
[5]   ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods [J].
Boni, Enrico ;
Bassi, Luca ;
Dallai, Alessandro ;
Guidi, Francesco ;
Meacci, Valentino ;
Ramalli, Alessandro ;
Ricci, Stefano ;
Tortoli, Piero .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (10) :1488-1495
[6]   Imaging Performance for Two Row-Column Arrays [J].
Bouzari, Hamed ;
Engholm, Mathias ;
Nikolov, Svetoslav Ivanov ;
Stuart, Matthias Bo ;
Thomsen, Erik Vilain ;
Jensen, Jorgen Arendt .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (07) :1209-1221
[7]   Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Phantom Study [J].
Bouzari, Hamed ;
Engholm, Mathias ;
Beers, Christopher ;
Stuart, Matthias Bo ;
Nikolov, Svetoslav Ivanov ;
Thomsen, Erik Vilain ;
Jensen, Jorgen Arendt .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (07) :1182-1192
[8]   Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Feasibility Study [J].
Bouzari, Hamed ;
Engholm, Mathias ;
Beers, Christopher ;
Stuart, Matthias Bo ;
Nikolov, Svetoslav Ivanov ;
Thomsen, Erik Vilain ;
Jensen, Jorgen Arendt .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (06) :978-988
[9]   VECTOR FLOW IMAGING COMPARED WITH PULSE WAVE DOPPLER FOR ESTIMATION OF PEAK VELOCITY IN THE PORTAL VEIN [J].
Brandt, Andreas Hjelm ;
Moshavegh, Ramin ;
Hansen, Kristoffer Lindskov ;
Bechsgaard, Thor ;
Lonn, Lars ;
Jensen, Jorgen Arendt ;
Nielsen, Michael Bachmann .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (03) :593-601
[10]   Broad-bandwidth radiation patterns of sparse two-dimensional vernier arrays [J].
Brunke, SS ;
Lockwood, GR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (05) :1101-1109